User interface Overview:
• In Home view, press the Back key to open the Options view.
• In the home view, press the OK key to open the menu.
• Use the arrow keys to navigate through the view.
• Press OK to open the highlighted Settings or items.
• Use the left and right arrow keys to highlight a value.
• Use the up and down arrow keys to set values.
• Press the Back key to cancel Settings or return to the previous view.
■ Home view
The home page view shows the reading of one of the three measurement signals. Use the left and right arrow keys to select the page.
The status bar at the top of the home view shows:
Control position (Loc for local control, Rem for remote control)
• Status icon
• Give the target value
From the home view, press the Back key to open the options view, and press the OK key to open the menu.
Use the up and down arrow keys to adjust the current given value.
■ Message view
For fault and warning information, see the ACS180 Firmware manual (3AXD50000467860[English]). To reset the fault, press the OK key (reset with soft key label).
■ Options view
To open the options view, press the back key in the home view.
In the Options view, you can:
• Set the control position
• Set the direction of the motor
• Set the given value
• Check the active fault
• View the list of active warnings
■ Menu
To open the menu, press the OK key in the home view.
To navigate through the menu, press the up and down arrow keys to move between menu items.
Menu item:
• Motor data view: Enter motor specifications.
• Motor Control view: Set motor control Settings.
• Control Macro view: Select the connection parameter macro.
• Diagnostic view: Read active faults and warnings.
• Parameter view: Open and edit the full parameter list.
Installation mode
You can install the inverter to the assembly plate with screws.
Installation requirements:
• Ensure that there is at least 75mm free space at the top and bottom of the inverter (in the cooling air inlet and outlet).
• Multiple inverters can be installed side by side.
• The maximum ambient temperature is 40°C if inverters of dimension R0 are installed side by side.
• Frequency converters with dimension R0 should be installed upright. The frequency converter with size R0 has no cooling fan.
• When installing a frequency converter with dimension R1, it is possible to tilt up to 90 degrees from the vertical direction to the full horizontal direction.
• Ensure that the heated cooling air discharged from the inverter does not enter the cooling air intake of other equipment.
• Install the inverter in the cabinet or housing. The cabinet-mounted inverter has IP20 protection rating.
Check the installation site
Check the installation site. Ensure:
• Adequate ventilation or cooling at the installation site to remove heat from the inverter. See Technical Data.
• The environmental conditions of the drive meet the relevant specifications. See technical data.
• The material above and below the walls and equipment behind the inverter is non-flammable.
• The mounting surface should be as close to vertical as possible and strong enough to support the inverter.
• Adequate space around the inverter for cooling, maintenance and operation.
• Ensure that there are no strong magnetic field sources near the inverter, such as high-current single-core wires or contactor coils. Strong magnetic fields can cause interference or lead to inaccuracies in the operation of the inverter.
Tools needed
To install the inverter mechanically, you need to use the following tools:
• Hand drill and suitable drill bit
• Bring a screwdriver or wrench with a suitable tool head
• Measuring tape and level
• Personal protective equipment.
Open the box and inspect the deliverables
The following is the frequency converter and its contents. Make sure all items are present and there are no signs of damage.
Package contents:
• Frequency converter
• Mounting accessories (wire clamps, metal flooring, screws, etc.)
• Quick installation and startup guide.
Check motor and inverter compatibility
The asynchronous AC induction motor or permanent magnet synchronous motor is used with the frequency converter. When the scalar motor control mode is used, multiple induction motors can be connected to the inverter simultaneously.
Ensure motor and inverter compatibility according to the rating table in the technical data.
Select power cable
■ General Guidelines
Select power and motor cables according to local regulations:
• Current: Select the cable that can carry the maximum load current and is suitable for the expected short circuit conditions provided by the power supply network. The installation method and ambient temperature affect the current carrying capacity of the cable. Comply with local regulations and laws.
• Temperature: For IEC equipment, the cable can withstand a temperature of at least 70 °C (158 °F) during long-term operation. For North America, choose cables with a temperature rating of at least 75 °C (167 °F).
• Voltage: 600 V AC cables can accept voltages up to 500 V AC. A 750 V AC cable can accept voltages up to 600 V AC. A 1000 V AC cable can accept voltages up to 690 V AC.
Choose Xiamen control Smith after sale worry
Excellent product quality
Only cooperate with manufacturers of first-line brands in the industry
Imports/Products
Good pre-sale service
Communicated with customers repeatedly about product model, quality, price and delivery date
Work with the customer to determine the best solution
Address user concerns in advance
Business execution in place
Ordered products delivered on time
Make perfect delivery plan to ensure the time limit
Assist users to handle the acceptance procedures
Perfect after-sales service
During the warranty period, problems will only be replaced and not repaired
Never put a problem on the back of your head
Service hotline 7x24 hours service
Solemn promise
1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.
2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.
3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.
4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.
5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.
6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.
7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.
email:1583694102@qq.com
wang@kongjiangauto.com