ABB mechanical frequency converter ACS180 inverter

F: | Au:佚名 | DA:2024-01-23 | 659 Br: | 🔊 点击朗读正文 ❚❚ | Share:

User interface Overview:

• In Home view, press the Back key to open the Options view.

• In the home view, press the OK key to open the menu.

• Use the arrow keys to navigate through the view.

• Press OK to open the highlighted Settings or items.

• Use the left and right arrow keys to highlight a value.

• Use the up and down arrow keys to set values.

• Press the Back key to cancel Settings or return to the previous view.

■ Home view

The home page view shows the reading of one of the three measurement signals. Use the left and right arrow keys to select the page.

The status bar at the top of the home view shows:

Control position (Loc for local control, Rem for remote control)

• Status icon

• Give the target value

From the home view, press the Back key to open the options view, and press the OK key to open the menu.

Use the up and down arrow keys to adjust the current given value.

■ Message view

For fault and warning information, see the ACS180 Firmware manual (3AXD50000467860[English]). To reset the fault, press the OK key (reset with soft key label).

■ Options view

To open the options view, press the back key in the home view.

In the Options view, you can:

• Set the control position

• Set the direction of the motor

• Set the given value

• Check the active fault

• View the list of active warnings

■ Menu

To open the menu, press the OK key in the home view.

To navigate through the menu, press the up and down arrow keys to move between menu items.

Menu item:

• Motor data view: Enter motor specifications.

• Motor Control view: Set motor control Settings.

• Control Macro view: Select the connection parameter macro.

• Diagnostic view: Read active faults and warnings.

• Parameter view: Open and edit the full parameter list.

Installation mode

You can install the inverter to the assembly plate with screws.

Installation requirements:

• Ensure that there is at least 75mm free space at the top and bottom of the inverter (in the cooling air inlet and outlet).

• Multiple inverters can be installed side by side.

• The maximum ambient temperature is 40°C if inverters of dimension R0 are installed side by side.

• Frequency converters with dimension R0 should be installed upright. The frequency converter with size R0 has no cooling fan.

• When installing a frequency converter with dimension R1, it is possible to tilt up to 90 degrees from the vertical direction to the full horizontal direction.

• Ensure that the heated cooling air discharged from the inverter does not enter the cooling air intake of other equipment.

• Install the inverter in the cabinet or housing. The cabinet-mounted inverter has IP20 protection rating.

Check the installation site

Check the installation site. Ensure:

• Adequate ventilation or cooling at the installation site to remove heat from the inverter. See Technical Data.

• The environmental conditions of the drive meet the relevant specifications. See technical data.

• The material above and below the walls and equipment behind the inverter is non-flammable.

• The mounting surface should be as close to vertical as possible and strong enough to support the inverter.

• Adequate space around the inverter for cooling, maintenance and operation.

• Ensure that there are no strong magnetic field sources near the inverter, such as high-current single-core wires or contactor coils. Strong magnetic fields can cause interference or lead to inaccuracies in the operation of the inverter.

Tools needed

To install the inverter mechanically, you need to use the following tools:

• Hand drill and suitable drill bit

• Bring a screwdriver or wrench with a suitable tool head

• Measuring tape and level

• Personal protective equipment.

Open the box and inspect the deliverables

The following is the frequency converter and its contents. Make sure all items are present and there are no signs of damage.

Package contents:

• Frequency converter

• Mounting accessories (wire clamps, metal flooring, screws, etc.)

• Quick installation and startup guide.

Check motor and inverter compatibility

The asynchronous AC induction motor or permanent magnet synchronous motor is used with the frequency converter. When the scalar motor control mode is used, multiple induction motors can be connected to the inverter simultaneously.

Ensure motor and inverter compatibility according to the rating table in the technical data.

Select power cable

■ General Guidelines

Select power and motor cables according to local regulations:

• Current: Select the cable that can carry the maximum load current and is suitable for the expected short circuit conditions provided by the power supply network. The installation method and ambient temperature affect the current carrying capacity of the cable. Comply with local regulations and laws.

• Temperature: For IEC equipment, the cable can withstand a temperature of at least 70 °C (158 °F) during long-term operation. For North America, choose cables with a temperature rating of at least 75 °C (167 °F).

• Voltage: 600 V AC cables can accept voltages up to 500 V AC. A 750 V AC cable can accept voltages up to 600 V AC. A 1000 V AC cable can accept voltages up to 690 V AC.

Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.



  • Basler XR2002F Voltage Regulator 9139400101
  • Basler 2D80367G23 DXCB De-Excitation Module 1200V 5000A
  • Basler SR4A-2B15B3A Static Regulator 120V 50/60Hz
  • Basler SSR 125-12NF Static Regulator 9 1859 00 106
  • Basler BE1-BPR Breaker Protection Relay 9272000315
  • Basler SSR 63-12 Static Regulator 9 1859 00 101
  • Basler AEM-2020 Analog Expansion Module
  • Basler BE 25231-001 Transformer BE25231001
  • Basler MVC 108 Manual Voltage Control 9037000102
  • Basler PSS-100-Y5 Power System Stabilizer 0.1-5.0Hz
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SSR 125-12 Static Voltage Regulator 9185900102
  • Basler Electric 90-73900-102 Power Supply (Westinghouse 2374A07G03)
  • Basler Electric 9400200117 Control Power Unit 12/24VDC 20W
  • Basler Electric BE1-87G Solid State Generator Differential Relay
  • Basler Electric BE1-32R Style C3ED1TA0S1F Solid State Protective Relay
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric SR8A2B06B3A Static Voltage Regulator
  • Basler MOC3502 90-72300-116 Motor Potentiometer
  • Basler SR4A2310B1A Static Voltage Regulator
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler SR4A-2B05A3E Static Regulator SR4A2B05A3E
  • Basler 9-0723-00-130 9072300130 Control Module
  • Basler BE1-79MA10A6JC0L0F Reclosing Relay
  • Basler CBS-377 Current Boost System 91096001
  • Basler SR4A1B05A3A Static Regulator 480V 62.5V 10VA
  • Basler BE159N A7ED1JC0S0F Protective Relay BE159N-0
  • Basler BE3-25A Auto-Synchronizer S.No. 728
  • Basler BE1-50 Instantaneous Overcurrent Relay G4EA1RG0N0F
  • Basler Electric KT3B Voltage Regulator
  • Basler Electric ACA2500-14GCSYM GigE Camera
  • Basler Electric XR2002F Voltage Regulator
  • Basler Electric BE1-50 Instantaneous Overcurrent Relay F2EA1PA0N5F
  • Basler Electric CBS 212A Current Boost System
  • Basler Electric BE147NE3FE1PC3N3F Negative Sequence Voltage Relay
  • Basler Electric BE1-79MA10A6JC0L0F Automatic Reclosing Relay
  • Basler Electric BE1-59N A6E E1C B0N1F Neutral Overvoltage Relay
  • Basler Electric MVC 108 Manual Voltage Control
  • Basler Electric BE1-59-A4E-E1C-A0N0F Overvoltage Relay
  • Basler BE1-57/27R Solid State Protective Relay
  • Basler BE3-25AX Time Overcurrent Relay
  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System