Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Six kinds of sewage treatment technology

来源: | 作者:佚名 | 发布时间 :2023-11-22 | 457 次浏览: | Share:

1. Physical law

Physical sewage treatment is the use of physical action to separate the main suspended pollutants in sewage, and the chemical properties of the water are not changed in the treatment process.

(1) Precipitation (gravity separation) sewage into the pool due to the reduced flow rate, the solid material in the sewage is precipitated under the action of neutrality, and the solid material is separated from the water, this process has a good separation effect, simple and easy to operate, and is widely used, such as the sedimentation tank and sedimentation tank of the sewage treatment plant. The sedimentation tank is mainly used to remove the dense solid particles in the sewage, and the sedimentation tank is mainly used to remove a large number of granular suspended solids in the sewage.

(2) Screening (interception) The use of screening media to intercept suspended matter in sewage. The equipment belonging to the sand filtration treatment is the grating, micro filter, sand filter, vacuum filter, filter press (the latter two are mainly used for sludge dehydration) and so on.

(3) Air flotation (floating) For some fine particles whose relative density is close to water, it is difficult to sink or float in water due to their own weight, air flotation devices can be used. This method will be the air into the sewage, and make it in the situation of tiny bubbles precipitated from the water, sewage density is close to the water of small particles of pollution impurities (such as emulsified oil) adhere to the bubble, and with the bubble to the surface, the formation of foam scum and remove. According to the different ways of air injection, air flotation equipment has pressure dissolved steam gas flotation, impeller gas flotation and jet gas flotation. In order to improve the effect of air flotation, sometimes it is necessary to add coagulant to the sewage.

(4) Centrifugal and swirl separation makes the sewage containing suspended solids or emulsified oil, because the quality of suspended solids and wastewater is different, the centrifugal force is different, the mass of suspended solids is thrown to the outside of the sewage, so that the suspended solids and sewage can be discharged through their respective discharge outlets outside the equipment, so that the sewage can be purified.

2. Chemical method

The chemical treatment of sewage is to add chemicals to sewage, use chemical reactions to separate and recycle pollutants in sewage, or convert them into harmless substances. There are the following chemical treatment methods.

(1) Coagulation method Coagulation method is to add a certain amount of chemicals to the sewage, through the reaction process of destabilization, bridging, etc., so that the pollutants in the sewage condense and settle. The colloidal pollutants in the water are usually negatively charged, and the colloidal particles repel each other to form a stable mixture. If the electrolyte with the opposite charge in the water (coagulant) can change the colloidal particles in the sewage to be electrically neutral, and condense into large particles under the action of molecular gravity.

(2) Neutralization method The process of eliminating excess acid and alkali in sewage by chemical methods so that its pH value reaches about neutral is called neutralization method. Alkali is used as a neutralizer in the treatment of acid-containing sewage, and acid is used as a neutralizer in the treatment of alkali-containing sewage, and CO2 can also be blown into the flue gas for neutralization. Acid and base refer to inorganic acid and inorganic base, generally in accordance with the principle of "waste to waste", can also be neutralized by chemicals, can be carried out continuously, can also be intermittent.

(3) The organic matter and inorganic matter in the dissolved state of the sewage by the REDOX method, after the addition of oxidants and reducing agents, oxidation and reduction occur due to the migration of electrons to form harmless substances. Commonly used oxidants are oxygen in the air, pure oxygen, bleaching powder, ozone, chlorine, etc. Oxidation method is mostly used to treat cyanogen containing phenol wastewater. The commonly used reducing agents are iron filings, ferrous sulfate, sodium bisulfite, etc. The reduction method is mostly used to treat wastewater containing chromium and mercury.

(4) The electrolysis method inserts an electrode in the waste water and passes a current to accept electrons on the cathode plate. In the electrolysis of water, oxygen is produced on the anode and hydrogen is produced on the cathode. The above comprehensive process causes oxidation on the anode and reduction on the cathode. At present, electrolysis is mainly used to treat wastewater containing chromium and cyanide.

(5) Sewage water adsorption treatment is mainly the use of solid material surface adsorption of pollutants in sewage, adsorption can be divided into physical adsorption and biological adsorption. Physical adsorption is produced between the adsorbent and the adsorbent under the action of molecular forces, does not produce chemical changes, and the chemical adsorption law makes the adsorbent and the adsorbent adsorbent under the action of chemical bond forces, so the chemical adsorption selectivity is strong. In addition, biological adsorption can also be produced under biological action. The adsorbents commonly used in sewage treatment are activated carbon, sulfonated coal, diatomite, coke and so on.

(6) Chemical precipitation method to add a chemical agent to the sewage, so that it reacts with some dissolved substances, resulting in insoluble salt precipitation. It is mainly used to treat industrial wastewater containing heavy metal ions.

 ⑺ ion exchange method ionization exchange method is widely used in sewage treatment. The ion exchanger used is divided into inorganic ion exchange method (natural zeolite and synthetic zeolite), organic ion exchange resin (strong acid cation resin, weak acid cation resin, strong basic anion resin, weak basic anion resin, chelate and resin, etc.). When ion exchange method is used to treat sewage, the selectivity of resin must be considered. The exchange ability of the resin for various ions is different, which mainly depends on the size of the affinity of each ion for the resin, also known as the size of the selectivity, and also takes into account the regeneration method of the resin.

(8) Membrane separation percolation, electrodialysis, ultrafiltration, microfiltration, reverse osmosis and other technologies for separating ions and molecules in water through a special semi-permeable membrane, collectively known as membrane separation method. Electrodialysis is mainly used for desalting water, recovering some metal ions and so on. Reverse osmosis is mainly a function of the chemical nature of the membrane surface. The particle size of the solute separated by it is small, the salt removal rate is high, and the required working pressure is large. The material used in ultrafiltration is the same as reverse osmosis, but ultrafiltration is a screening effect, the separation of solute particle size is large, the water permeability is high, the salt removal rate is low, and the working pressure is small.

3. Biological law

The biofilm method of sewage is to take certain artificial measures to create an environment conducive to the growth and reproduction of microorganisms, so that microorganisms proliferate in large numbers, so that microbial oxidation and decomposition of organic pollutants are degraded and converted into harmless substances, so that sewage can be purified. Biological treatment can be divided into two categories: aerobic treatment and anaerobic treatment. The former has high efficiency, good effect and wide use, and is the main method of biological treatment. There are several processes that belong to biological treatment.

(1) Activated sludge method is the most widely used biological treatment technology. The air is continuously pumped into the sewage containing a large number of dissolved organic pollutants, and after a period of time, the water not only forms a flocculant with a large number of aerobic microorganisms - active sludge, the activated sludge can adsorb the organic matter in the water, the microorganisms in the activated sewage on the activated sludge take the organic matter as food, obtain energy, and constantly multiply, and the organic matter is decomposed and removed. To purify the sewage. Generally, the effluent treated by the aeration tank is the sewage mixed liquid containing a large amount of activated sludge, which is separated by precipitation, and the water is purified and discharged. The sludge after precipitation and separation is used as seed mud, and part of it is returned to the aeration tank. Since the emergence of activated sludge method, after more than 80 years of evolution, there have been various variations of activated sludge method, but its principle and process have not fundamentally changed.

(2) Ordinary activated sludge method This method has been widely used and is a common process in many sewage treatment plants. The traditional activated sludge method is to introduce sewage and return sludge from the first section of the aeration tank and flow out in a push flow to the end of the aeration tank. This method is suitable for treating sewage with high requirements and stable water quality, but it is weak in adaptability to load changes. Later on, some improved forms have been produced on this basis.

(3) In order to make the organic load in the tank close to a certain value, the sewage is divided into several points, which is conducive to solving the overload problem.

(4) The activated activated sludge in the contact tank adsorbed polluting substances, and after the separation of sludge and water, the adsorbed polluting substances were oxidized in the aeration tank. This method is beneficial to increase the amount of sewage treatment and has a certain ability to resist the impact load.

(5) Delayed aeration method Sewage in the aeration tank to extend the aeration time, is conducive to complete oxidation, less sludge, this method is suitable for small sewage treatment plants.

(6) Anaerobic - anoxic - aerobic activated sludge method in the conventional activated sludge method to remove organic pollutants at the same time, in order to effectively remove nitrogen and phosphorus and other nutrients, people combine anaerobic, anoxic, aerobic conditions into the activated sludge method, so that anaerobic - anoxic - aerobic conditions exist at the same time in the reaction aeration tank or repeated cycles to achieve the formation of anaerobic - anoxic - aerobic activated sludge method. There are also processes using anaerobic-aerobic activated sludge method.

With the batch activated sludge process, the sewage flows to a single reaction tank, and each process is controlled by the program according to time. In a working cycle of the reaction pool, the operating procedures are followed by inlet, reaction, precipitation, outlet and standby processes. This method is suitable for small and medium-sized water quantity and high effluent quality, which is conducive to automatic control. Through the adjustment of operation, this method can also be used for phosphorus and nitrogen removal and chemical treatment, which is conducive to sewage reuse. In recent years, SBR process has developed rapidly, especially with the development of instrument and automatic control technology and equipment, new batch activated sludge process continues to emerge, such as CASS process, CAST process, IDEA process, MSBR process and UNITANK process.

⑻AB method is the abbreviation of adsorption degradation process, which belongs to the ultra-high load activated sludge method. It is a series system of two activated sludge methods, and each of them has an independent secondary sedimentation tank. This method has strong impact load resistance and is beneficial for phosphorus and nitrogen removal and chemical treatment, especially for wastewater with high concentration and large variation of water quality and quantity. (9) Oxidation ditch The oxidation ditch is a continuous ring aeration pool, the pool is longer, shallow depth. Oxidation ditch system is a kind of treatment technology with low cost, simple structure and easy maintenance management. Its effluent quality is good, nitrogen removal can be carried out, and it is conducive to delayed aeration.

4. Biofilm method

The sewage continuously flows through the solid filler, and a sludge scale-like biofilm can be formed on the filler. A large number of microorganisms multiply on the biofilm, absorb and degrade the organic pollutants in the water, and can play the same role as the activated sludge in purifying sewage. The dead biofilm that falls off the filler flows into the sedimentation tank with the sewage and is clarified and purified by the sedimentation tank. Biofilm has a variety of treatment structures, such as biological filter media, biological turntable, biological contact oxidation and biological fluidized bed.

(1) Biological filter biological filter is developed on the basis of the principle of soil self-purification, there are fixed fillers in the filter, the sewage flows through the filter material contact, microorganisms form biofilm on the surface of the filter material. The sewage purification plant consists of a filter bed, a water distribution system and a drainage system to provide microbial growth and habitat. Biological filter is simple to operate, low cost, suitable for small and medium-sized towns and remote areas. Biological filters are divided into ordinary biological filters, high load biological filters, tower biological filters and aerated biological filters.

(2) The biological turntable is driven by the transmission device to rotate the biological turntable at a certain speed in the contact reaction tank, and the alternating contact with the air and sewage, each cycle to complete the process of adsorption - oxygen absorption - oxidation decomposition, through continuous rotation, so that the pollutants in the sewage are constantly decomposed and oxidized. In addition to the biological turntable process, there are primary and secondary sedimentation tanks. The biological turntable has a wide range of adaptation, which can be applied to domestic sewage and various industrial wastewater. At the same time, the power consumption of the biological turntable is low, the impact load resistance is strong, and the management and maintenance are simple.

(3) Biological contact oxidation in the pool is filled with fillers, so that the oxygenated sewage is immersed in all the fillers, the filler is covered with biofilm, the sewage is in contact with the biofilm, the organic matter in the water is adsorbed by microorganisms, oxidation decomposition and conversion into a new biofilm. The biofilm that falls off from the filler is removed with the water flow to the secondary sedimentation tank, and the sewage is purified. The biological contact oxidation method has a strong ability to adapt to the impact load, the sludge production is small, and the effluent quality can be guaranteed. (4) The biological fluidized bed uses small inert particles with a relative density of more than 1, such as sand, charcoal, activated carbon, ceramic particles, etc., as a carrier, microorganisms adhere to the surface of the carrier, forming a biofilm, oxygenated sewage flows from top to bottom so that the carrier is in a fluidized body, and the biofilm is in full contact with the sewage. The treatment efficiency of biological fluidized bed is high, it can adapt to large impact load and occupy a small area.

5, natural biological treatment

The use of microorganisms growing and propagating under natural conditions to treat sewage, forming an ecosystem composed of water-microbe-plants, and conducting a series of physical-chemical and biological purification of pollutants can make full use of nutrients in sewage, which is conducive to the growth of green plants, and realize the recycling, harmfulness and stabilization of sewage. The process is simple, the construction and operation costs are low, high efficiency, is a kind of ecological principle of sewage treatment, but easy to be affected by natural conditions, occupy a large area. The main aquatic plant pond, aquatic animal pond, land treatment system and the above process combination system. The stabilization pond uses microorganisms growing naturally in pond water to treat sewage, and the photosynthesis of algae growing in the pond and the action of atmospheric oxygen supply oxygen to the pond. In the stabilization pond, the sewage stays for a long time, and its biochemical process is similar to that of natural water purification. According to the type of microbial reaction, stable ponds can be divided into aerobic ponds, facultative ponds, anaerobic ponds and aerated ponds. Land treatment takes land purification as the core, and uses soil filtration and retention, adsorption, chemical reaction and precipitation as well as microbial decomposition to treat pollutants in sewage. Crops growing on land can make full use of water and nutrients in sewage. Such as sewage farmland irrigation is a way of land treatment.

6, anaerobic biological treatment

It is mainly used for the treatment of high concentration organic industrial wastewater and organic sludge which is difficult to degrade by the use of anaerobic bacteria. In recent years, there has been great development in this field, and a series of new high-efficiency anaerobic treatment structures have been created, such as anaerobic filter, anaerobic turntable, upflow anaerobic sludge bed, anaerobic fluidized bed and other high-efficiency reaction devices. This method has low energy consumption and can produce energy, and the sludge amount is small.


  • ABB HIEE300927R0101 UBC717AE101 High Voltage Inverter Board
  • ABB UFC721AE101 3BHB002916R0101 PC Board
  • ABB 5SHY4045L0003 3BHB021400 3BHE019719R0101 GVC736BE101 Diode and grid drive circuits
  • ABB 3BHE019719R0101 GVC736BE101 IGCT Module
  • ABB REM620A_F NAMBBABA33E5BNN1XF Protective Relay
  • ABB PPD113B03-26-100110 3BHE023584R2634 Power Distribution Module
  • ABB MB810 Module Mounting locations
  • ABB 3BHL000986P7000 LXN1604-6 POWER SUPPLY
  • ABB VBX01BA I/O Control Module
  • ABB AI03 AI module, 8-CH, 2-3-4 Wire RTDs
  • ABB 1TGE120010R1300 Industrial Control Module
  • ABB 216BM61b HESG448267R1021 Advanced Process Control Module
  • ABB BDD110 HNLP205879R1 Digital I/O Module
  • ABB IEMPU02 Power Supply Module
  • ABB G3FE HENF452697R1 High performance control module
  • ABB G3FD HENF452692R1 High-Performance Industrial Control Module
  • ABB B5EC HENF105077R1 Electronic Motor Protection Relay
  • ABB G3EFa HENF450295R2 Industrial Automation Module
  • ABB B5EEd HENF105082R4 Electronic Motor Protection Relay
  • ABB O3EId HENF452777R3 Digital Output Module
  • ABB NWX511a-2/R HESG112548R12 Industrial Automation Module
  • ABB E3ES Power communication module
  • ABB O3EX HENF315845R2 Industrial Control Module
  • ABB O3EHa HENF315087R2 Digital Output Module
  • ABB E3ED High-Performance Industrial Controller
  • ABB O3EGb HENF315118R2 Digital Output Module
  • ABB O3ED Digital Input Module
  • ABB O3ES HENF445789R1 Digital Input Module
  • ABB G3ESa HENF318736R1 control module
  • ABB 8025-235 Industrial Control Module
  • ABB 216NG61A HESG441633R1 HESG216875/K main control board
  • ABB SCYC51020 58052582G programmable Logic Controller
  • ABB RED670 Line differential protection
  • ABB PP825A 3BSE042240R3 Touch Screen Panel
  • ABB SCYC51020 58052582/G pulse trigger board
  • ALSTOM COP232.2 VME A32/D32.029.232 446 Controller Unit
  • ABB AO2000 LS25 Laser analyzers
  • ABB LM80 Laser level transmitter
  • ABB PM803F 3BDH000530R1 Base Unit 16 MB
  • ABB SD822 3BSC610038R1 Power Supply Device
  • ABB PCD235B1101 3BHE032025R1101 Industrial Control Module
  • ABB AZ20/112112221112E/STD Control Module
  • ABB UAD142A01 3BHE012551R0001 Industrial Control Module
  • ABB 5SHY35L4503 3BHB004693R0001 3BHB004692R0002 5SXE01-0127 main control board
  • ABB FET3251C0P184C0H2 High-Performance Power Module
  • ABB CAI04 Ability ™ Symphony ® Plus Hardware Selector
  • ABB R474A11XE HAFAABAAABE1BCA1XE output hybrid module
  • ABB REF542PLUS 1VCR007346 Compact Digital Bay Control
  • ABB REF542PLUS 1VCF752000 Feeder Terminal Panel
  • ABB PPD113B03-26-100100 3BHE023584R2625 output hybrid module
  • ABB 3BHE022293R0101 PCD232A Communication Interface Unit
  • ABB CI857K01 3BSE018144R1 Module Controller
  • ABB 3ASC25H216A DATX132 Industrial Controller
  • ABB LWN2660-6 High-Voltage Industrial Controller
  • ABB 1MRK00008-KB Control Module
  • ABB SC540 3BSE006096R1 Submodule Carrier
  • ABB REF615C_C HCFFAEAGANB2BAN1XC feeder protection and measurement and control device
  • ABB S-073N 3BHB009884R0021 multi-function servo driver
  • ABB SK827005 SK827100-AS 480V 60HZ coil
  • GE 029.381208 module
  • ABB REF615E_E HBFHAEAGNCA1BNN1XE Module
  • ABB TP830 3BSE018114R1 Baseplate Module
  • ABB TK803V018 3BSC950130R1 Cable Assembly
  • ABB DSRF197 3BSE019297R1 Controller Module
  • ABB DSAO120A 3BSE018293R1 Advanced Analog Output Board
  • ABB DSDP170 57160001-ADF Pulse Counting Module
  • ABB DSBC176 3BSE019216R1 Bus Extender Board
  • ABB DSDO115A 3BSE018298R1 Digital Output Module
  • ABB PM865K01 3BSE031151R1 Processor Unit HI
  • ABB 5SHY3545L0016 3BHB020720R0002 3BHE019719R0101 GVC736BE101 auxiliary DC power supply unit
  • ABB TP853 3BSE018126R1 Power Supply Module
  • ABB REM545AG228AAAA High Precision Control Module
  • ABB CI626A 3BSE005029R1 Communication Interface Module
  • ABB REM615C_D HCMJAEADAND2BNN1CD Motor protection and control
  • ABB TP857 3BSE030192R1 DCS System
  • ABB PP865A 3BSE042236R2 Touch Panel
  • ABB SCYC51020 58052582H Industrial Automation Control Module
  • ABB SCYC51090 58053899E Control Module
  • ABB CB801 3BSE042245R1 Profibus DP Slave Expansion Module
  • ABB 5SHY4045L0001 3BHB018162R0001 IGCT Module
  • ABB 5SHY6545L0001 AC10272001R0101 5SXE10-0181 High-Power IGCT Module
  • ABB RMU811 Module Termination Unit
  • ABB TVOC-2-240 1SFA664001R1001 Industrial Control Module
  • ABB LDSTA-01 63940143B Input/Output (I/O) Module
  • ABB GJR5252300R3101 07AC91H Analog Input/Output Module
  • ABB GJR5252300R3101 07AC91F Industrial Control Module
  • ABB TB711F 3BDH000365R0001 Industrial Control Module
  • ABB TU715F 3BDH000378R0001 I/O Terminal Unit (ITU)
  • ABB DC732F 3BDH000375R0001 Industrial Controller
  • ABB TTH300 Head-mount temperature transmitter
  • ABB UNS3670A-Z V2 HIEE205011R0002 Industrial Automation Module
  • ABB RC527 3BSE008154R1 Redundant System Control Module
  • ABB 5SHY5055L0002 3BHE019719R0101 GVC736BE101 Industrial Control Module
  • ABB PM866 3BSE050200R1 AC800M series PLC core controller
  • ABB UFC718AE01 HIEE300936R0001 Main Circuit Interface Board
  • ABB DSAI130A 3BSE018292R1 Industrial I/O Module Controller
  • ABB 07KT98 GJR5253100R0278 Advanced Controller Module
  • ABB PFTL101B-5.0kN 3BSE004191R1 Power Conversion Module
  • ABB 5SHX1445H0002 3BHL000387P0101 IGCT Module
  • ABB 3HNM07686-1 3HNM07485-1/07 Controller Module
  • ABB DSCS131 57310001-LM DS Communication Board
  • ABB DSBC172 57310001-KD BUS REPEATER
  • ABB DSRF180A 57310255-AV Digital Remote I/O Module
  • ABB DSTC175 57310001-KN Precision Control Module
  • ABB DSSB140 48980001-P Battery Unit Industrial Control Module
  • ABB UAC389AE02 HIEE300888R0002 PCB Board
  • ABB PFTL101B 20KN 3BSE004203R1 DCS Module
  • ABB UFC718AE101 HIEE300936R0101 PCB Circuit Board
  • ABB UNS2880b-P,V2 3BHE014967R0002 Control Board
  • ABB UNS0887A-P 3BHE008128R0001 Communication Module
  • ABB UNS2882A-P,V1 3BHE003855R0001 EGC Board
  • ABB UNS2882A 3BHE003855R0001 Interface Board
  • ABB UNS4881b,V4 3BHE009949R0004 Controller
  • ABB 216EA62 1MRB150083R1/F 1MRB178066R1/F 216EA62 Redundant system modules
  • ABB 216DB61 HESG324063R100/J Controller Module
  • ABB PFSK142 3BSE006505R1 Control board
  • ABB DSAI133A 3BSE018290R1 Analog Input Module
  • ABB PFTL201C-10KN 3BSE007913R0010 Load Cells
  • ABB CI858-1 3BSE018137R1 Industrial Module
  • ABB 5SHY35L4520 5SXE10-0181 AC10272001R0101 Controller
  • ABB TU847 3BSE022462R1 Module Termination Unit
  • ABB 6231BP10910 PLC Analog Output Module
  • ABB 07BR61R1 GJV3074376R1 Distributed I / O Coupler
  • ABB DI93A HESG440355R3 Digital Input Module
  • ABB IC660BBA104 6231BP10910 Industrial Control Module
  • ABB TP858 3BSE018138R1 Module Controller
  • ABB PFEA111-65 3BSE050090R65 Tension Electronics Module
  • ABB DSMB-02C 3AFE64666606 Power Supply Board