Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Six kinds of sewage treatment technology

F: | Au:佚名 | DA:2023-11-22 | 792 Br: | 🔊 点击朗读正文 ❚❚ | Share:

1. Physical law

Physical sewage treatment is the use of physical action to separate the main suspended pollutants in sewage, and the chemical properties of the water are not changed in the treatment process.

(1) Precipitation (gravity separation) sewage into the pool due to the reduced flow rate, the solid material in the sewage is precipitated under the action of neutrality, and the solid material is separated from the water, this process has a good separation effect, simple and easy to operate, and is widely used, such as the sedimentation tank and sedimentation tank of the sewage treatment plant. The sedimentation tank is mainly used to remove the dense solid particles in the sewage, and the sedimentation tank is mainly used to remove a large number of granular suspended solids in the sewage.

(2) Screening (interception) The use of screening media to intercept suspended matter in sewage. The equipment belonging to the sand filtration treatment is the grating, micro filter, sand filter, vacuum filter, filter press (the latter two are mainly used for sludge dehydration) and so on.

(3) Air flotation (floating) For some fine particles whose relative density is close to water, it is difficult to sink or float in water due to their own weight, air flotation devices can be used. This method will be the air into the sewage, and make it in the situation of tiny bubbles precipitated from the water, sewage density is close to the water of small particles of pollution impurities (such as emulsified oil) adhere to the bubble, and with the bubble to the surface, the formation of foam scum and remove. According to the different ways of air injection, air flotation equipment has pressure dissolved steam gas flotation, impeller gas flotation and jet gas flotation. In order to improve the effect of air flotation, sometimes it is necessary to add coagulant to the sewage.

(4) Centrifugal and swirl separation makes the sewage containing suspended solids or emulsified oil, because the quality of suspended solids and wastewater is different, the centrifugal force is different, the mass of suspended solids is thrown to the outside of the sewage, so that the suspended solids and sewage can be discharged through their respective discharge outlets outside the equipment, so that the sewage can be purified.

2. Chemical method

The chemical treatment of sewage is to add chemicals to sewage, use chemical reactions to separate and recycle pollutants in sewage, or convert them into harmless substances. There are the following chemical treatment methods.

(1) Coagulation method Coagulation method is to add a certain amount of chemicals to the sewage, through the reaction process of destabilization, bridging, etc., so that the pollutants in the sewage condense and settle. The colloidal pollutants in the water are usually negatively charged, and the colloidal particles repel each other to form a stable mixture. If the electrolyte with the opposite charge in the water (coagulant) can change the colloidal particles in the sewage to be electrically neutral, and condense into large particles under the action of molecular gravity.

(2) Neutralization method The process of eliminating excess acid and alkali in sewage by chemical methods so that its pH value reaches about neutral is called neutralization method. Alkali is used as a neutralizer in the treatment of acid-containing sewage, and acid is used as a neutralizer in the treatment of alkali-containing sewage, and CO2 can also be blown into the flue gas for neutralization. Acid and base refer to inorganic acid and inorganic base, generally in accordance with the principle of "waste to waste", can also be neutralized by chemicals, can be carried out continuously, can also be intermittent.

(3) The organic matter and inorganic matter in the dissolved state of the sewage by the REDOX method, after the addition of oxidants and reducing agents, oxidation and reduction occur due to the migration of electrons to form harmless substances. Commonly used oxidants are oxygen in the air, pure oxygen, bleaching powder, ozone, chlorine, etc. Oxidation method is mostly used to treat cyanogen containing phenol wastewater. The commonly used reducing agents are iron filings, ferrous sulfate, sodium bisulfite, etc. The reduction method is mostly used to treat wastewater containing chromium and mercury.

(4) The electrolysis method inserts an electrode in the waste water and passes a current to accept electrons on the cathode plate. In the electrolysis of water, oxygen is produced on the anode and hydrogen is produced on the cathode. The above comprehensive process causes oxidation on the anode and reduction on the cathode. At present, electrolysis is mainly used to treat wastewater containing chromium and cyanide.

(5) Sewage water adsorption treatment is mainly the use of solid material surface adsorption of pollutants in sewage, adsorption can be divided into physical adsorption and biological adsorption. Physical adsorption is produced between the adsorbent and the adsorbent under the action of molecular forces, does not produce chemical changes, and the chemical adsorption law makes the adsorbent and the adsorbent adsorbent under the action of chemical bond forces, so the chemical adsorption selectivity is strong. In addition, biological adsorption can also be produced under biological action. The adsorbents commonly used in sewage treatment are activated carbon, sulfonated coal, diatomite, coke and so on.

  • Basler XR2002F Voltage Regulator 9139400101
  • Basler 2D80367G23 DXCB De-Excitation Module 1200V 5000A
  • Basler SR4A-2B15B3A Static Regulator 120V 50/60Hz
  • Basler SSR 125-12NF Static Regulator 9 1859 00 106
  • Basler BE1-BPR Breaker Protection Relay 9272000315
  • Basler SSR 63-12 Static Regulator 9 1859 00 101
  • Basler AEM-2020 Analog Expansion Module
  • Basler BE 25231-001 Transformer BE25231001
  • Basler MVC 108 Manual Voltage Control 9037000102
  • Basler PSS-100-Y5 Power System Stabilizer 0.1-5.0Hz
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SSR 125-12 Static Voltage Regulator 9185900102
  • Basler Electric 90-73900-102 Power Supply (Westinghouse 2374A07G03)
  • Basler Electric 9400200117 Control Power Unit 12/24VDC 20W
  • Basler Electric BE1-87G Solid State Generator Differential Relay
  • Basler Electric BE1-32R Style C3ED1TA0S1F Solid State Protective Relay
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric SR8A2B06B3A Static Voltage Regulator
  • Basler MOC3502 90-72300-116 Motor Potentiometer
  • Basler SR4A2310B1A Static Voltage Regulator
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler SR4A-2B05A3E Static Regulator SR4A2B05A3E
  • Basler 9-0723-00-130 9072300130 Control Module
  • Basler BE1-79MA10A6JC0L0F Reclosing Relay
  • Basler CBS-377 Current Boost System 91096001
  • Basler SR4A1B05A3A Static Regulator 480V 62.5V 10VA
  • Basler BE159N A7ED1JC0S0F Protective Relay BE159N-0
  • Basler BE3-25A Auto-Synchronizer S.No. 728
  • Basler BE1-50 Instantaneous Overcurrent Relay G4EA1RG0N0F
  • Basler Electric KT3B Voltage Regulator
  • Basler Electric ACA2500-14GCSYM GigE Camera
  • Basler Electric XR2002F Voltage Regulator
  • Basler Electric BE1-50 Instantaneous Overcurrent Relay F2EA1PA0N5F
  • Basler Electric CBS 212A Current Boost System
  • Basler Electric BE147NE3FE1PC3N3F Negative Sequence Voltage Relay
  • Basler Electric BE1-79MA10A6JC0L0F Automatic Reclosing Relay
  • Basler Electric BE1-59N A6E E1C B0N1F Neutral Overvoltage Relay
  • Basler Electric MVC 108 Manual Voltage Control
  • Basler Electric BE1-59-A4E-E1C-A0N0F Overvoltage Relay
  • Basler BE1-57/27R Solid State Protective Relay
  • Basler BE3-25AX Time Overcurrent Relay
  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System