Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Current situation and development trend of municipal sewage treatment and reuse in China

来源: | 作者:佚名 | 发布时间 :2023-11-22 | 383 次浏览: | Share:

This paper mainly introduces the status quo of urban sewage treatment and reuse in China under the current era background, and discusses the future development trend of urban sewage treatment and reuse under the current state.

In recent years, China has accelerated the process of social urbanization, and the number of people has also shown a trend of rapid growth, the contradiction between sewage treatment and residents' life in urban development has been highlighted, and has received extensive attention from all walks of life. According to relevant data, as of the end of June 2019, the sewage treatment plants of cities in China have reached more than 5,000 (excluding township sewage treatment plants and industries), and the sewage treatment capacity has reached 2.1×108 m3/d. Although the number of urban sewage treatment plants is gradually increasing, it can not meet the current needs of urban development, and the current status of sewage treatment in urban agglomerations in China is still not optimistic. Only by effectively solving the problem of urban sewage treatment can we effectively guarantee the steady improvement of the quality of life of urban residents and ensure the ecological and sustainable development of the city.

First, the current situation of urban sewage treatment and recycling in China

The state increasingly attaches importance to urban sewage treatment and reuse, and sewage treatment plants actively innovate A variety of effective solutions for the treatment and reuse of urban sewage, such as A-A-O process, A-O process, oxidation ditch process and SBR process, and even the deep sewage treatment and reuse technology that has been widely used in urban sewage treatment plants. But at present, the situation of municipal sewage reuse is still not objective. The main reasons for the low efficiency in the reuse of municipal sewage are as follows:

1. Shortage of funds for sewage treatment and reuse

Urban sewage treatment and reuse can be used for flushing toilets, urban road greening, domestic water, landscape water, etc. According to the relevant regulations of reuse water, the requirements of fecal Escherichia coli, residual chlorine, suspended matter and other indicators are stricter than Grade A, and the effluent of most sewage treatment plants has not yet met the requirements. In order to improve the capacity of reuse water for sewage treatment, it is necessary to strengthen the construction of the sewage treatment plant. However, in the process of establishing the plant, a large amount of financial support is urgently needed, such as site construction funds, equipment introduction funds and machinery and equipment maintenance funds. In addition, when purchasing related chemical reagents and updating technical means, it is necessary to improve the quality of the plant. Strong financial backing is needed everywhere. However, at the current stage, the financial support given to urban sewage treatment plants by local government departments in China is not sufficient, which leads to insufficient construction of urban sewage treatment plants and low technical level, and ultimately leads to China's urban sewage treatment plants in the performance of sewage treatment capacity can not get the ideal effect.

2. Technical problems of sewage treatment and reuse

China has a vast area, the urban division is very detailed, at present, the process of urban sewage treatment and reuse is often limited by the level of urban economic development and scientific and technological input, and even affected by the urban geographical environment, resulting in our city in the reuse of sewage is relatively slow. If the technical problems can not be solved in the sewage treatment and reuse of the urban sewage treatment plant, it will lead to the difficulty of the designed sewage treatment and recycling scheme, and it will not be able to successfully achieve the goal of urban sewage treatment and reuse. Most urban sewage factory sewage treatment technology is introduced from abroad, resulting in sewage treatment technology can not match the actual situation of our city, the actual treatment capacity may not be able to reach the design treatment capacity.

Second, China's sewage treatment and reuse process technical support

At present, most domestic and foreign sewage treatment in the use of secondary treatment method, the core is the traditional activated sludge method. The processes used in the treatment of sewage include A-A-O process, A-O process, oxidation ditch process and SBR process. At present, these processes are relatively mature, and the effect of treating sewage is also relatively good.

1, A-A-O sewage treatment process

A-a-o wastewater treatment process is also known as anaerobic - anoxic - aerobic process, this process has A wide range of applications, the southern region of China is more common use of such technology. The principle is to set up anaerobic areas, anoxic areas and aerobic areas in the sewage treatment system to achieve the purpose of biological nitrogen and phosphorus removal.

2. SBR process

SBR process is also known as the continuous batch activated sludge treatment process, this process requires the use of a pool as a tool, the pool as an aeration tank to develop secondary precipitation, this method is different from the traditional way of space or time segmentation, more suitable for sewage treatment in small-scale cities.

  • FOXBORO P0926KK PLC system functional module
  • FOXBORO P0924AW wireless pressure transmitter
  • FOXBORO P0916NK differential pressure transmission cable
  • FOXBORO P0916JQ PLC module
  • FOXBORO P0916JP I/A series control module
  • FOXBORO P0916GG Digital Input Module
  • FOXBORO P0916DV I/A series digital input module
  • FOXBORO P0916DC Terminal Cable
  • FOXBORO P0916DB I/A series PLC module
  • FOXBORO P0914ZM recognition module
  • FOXBORO P0902YU control module
  • FOXBORO P0901XT Process Control Unit
  • FOXBORO P0800DV fieldbus extension cable
  • FOXBORO P0800DG Standard Communication Protocol Module
  • FOXBORO P0800DB Universal I/O Module
  • FOXBORO P0800DA Industrial Control Module
  • FOXBORO P0800CE control module
  • FOXBORO P0700TT Embedded System
  • FOXBORO P0500WX Control System Module
  • FOXBORO P0500RY Terminal Cable Assembly
  • FOXBORO P0500RU control module
  • FOXBORO P0500RG Terminal Cable
  • FOXBORO P0400ZG Node Bus NBI Interface Module
  • FOXBORO P0400GH fieldbus power module
  • FOXBORO FBM207B Voltage Monitoring/Contact Induction Input Module
  • FOXBORO FBM205 Input/Output Interface Module
  • FOXBORO FBM18 Industrial Controller Module
  • FOXBORO FBM12 Input/Output Module
  • FOXBORO FBM10 Modular Control System
  • FOXBORO FBM07 Analog/Digital Interface Module
  • FOXBORO FBM05 redundant analog input module
  • FOXBORO FBM02 thermocouple/MV input module
  • FOXBORO FBI10E fieldbus isolator
  • FOXBORO DNBT P0971WV Dual Node Bus Module
  • FOXBORO CP30 Control Processor
  • FOXBORO CM902WX Communication Processor
  • FOXBORO AD202MW Analog Output Module
  • FOXBORO 14A-FR Configuration and Process Integration Module
  • FOXOBORO 130K-N4-LLPF Controller
  • FUJI FVR004G5B-2 Variable Frequency Drive
  • FUJI FVR008E7S-2 High Efficiency Industrial Inverter
  • FUJI FVR008E7S-2UX AC driver module
  • FUJI RPXD2150-1T Voltage Regulator
  • FUJI NP1PU-048E Programmable Logic Control Module
  • FUJI NP1S-22 power module
  • FUJI NP1AYH4I-MR PLC module/rack
  • FUJI NP1BS-06/08 Programmable Controller
  • FUJI NP1X3206-A Digital Input Module
  • FUJI NP1Y16R-08 Digital Output Module
  • FUJI NP1Y32T09P1 high-speed output module
  • FUJI NP1BS-08 Base Plate​
  • FUJI A50L-2001-0232 power module
  • FUJI A50L-001-0266 # N Programmable Logic Control Module
  • GE GALIL DMC9940 Advanced Motion Controller
  • GE DMC-9940 Industrial Motion Control Card
  • GE IS200AEADH4A 109W3660P001 Input Terminal Board
  • GE IC660HHM501 Portable Genius I/O Diagnostic Display
  • GE VMIVME 4140-000 Analog Output Board
  • GE VMIVME 2540-300 Intelligent Counter
  • GE F650NFLF2G5HIP6E repeater
  • GE QPJ-SBR-201 Circuit Breaker Module
  • GE IC200CHS022E Compact I/O Carrier Module
  • GE IC695PSD140A Input Power Module
  • GE IC695CHS016-CA Backboard
  • GE IC800SS1228R02-CE Motor Controller
  • GE IS215WEMAH1A Input/Output Communication Terminal Board
  • GE CK12BE300 24-28V AC/DC Contactor
  • GE CK11CE300 contactor
  • GE DS3800NB1F1B1A Control Module
  • GE VMIVME2540 Intelligent Counter
  • GE 369B1859G0022 High Performance Turbine Control Module
  • GE VME7865RC V7865-23003 350-930007865-230003 M AC contactor
  • GE SR489-P5-H1-A20 Protection Relay
  • GE IS200AEPGG1AAA Drive Control Module
  • GE IS215UCCCM04A Compact PCI Controller Board
  • GE VME7768-320000 Single Board Computer
  • GE SR489-P5-LO-A1 Generator Protection Relay
  • GE IS215WETAH1BB IS200WETAH1AGC Input/Output Interface Module
  • GE D20 EME210BASE-T Ethernet Module
  • GE IS200EXHSG3REC high-speed synchronous input module
  • GE IS200ECTBG1ADE exciter contact terminal board
  • GE VPROH2B IS215VPROH2BC turbine protection board
  • GE F650BFBF2G0HIE feeder protection relay
  • GE SLN042 IC086SLN042-A port unmanaged switch
  • GE SR489-P1-HI-A20-E Generator Management Relay
  • GE IS400JPDHG1ABB IS410JPDHG1A track module
  • GE IS410STAIS2A IS400STAIS2AED Industrial Control Module
  • GE IS410STCIS2A IS400STCIS2AFF Industrial Control Module
  • GE DS200DCFBG2BNC DS200DCFBG1BNC DC Feedback Board
  • GE VME5565 VMIVME-5565-11000 332-015565-110000 P Reflective Memory
  • GE VMIVME-7807 VMIVMME-01787-414001 350-00010078007-414001 D module
  • GE IS220PDOAH1A 336A4940CSP2 Discrete Output Module
  • GE VMIVME-4150 Analog Output Module
  • GE WESDAC D20 PS Industrial Power Module
  • GE 369B1860G0031 servo drive module
  • GE 369B1859G0021 Input/Output Module
  • GE 208D9845P0008 Motor Management Relay
  • GE IS420UCSCH1A-F.V0.1-A Independent Turbine Controller
  • GE D20EME10BASE-T 820-0474 Ethernet Interface Module
  • GE DS200DCFBG2BNC MRP445970 DC Feedback Board
  • GE IC800SSI228RD2-EE servo motor controller
  • GE IS200JPDMG1ACC S1AT005 Digital Input/Output (I/O) Module
  • GE IS200TSVCH1AED servo input/output terminal board
  • GE IS200TTURH1CCC S1DF00Z Terminal Turbine Plate
  • GE IS200TSVCH1ADC S1CX01H servo input-output board
  • GE IS200TRPGH1BDD S1C5029 Trip Solenoid Valve Control Board
  • GE IS220YAICS1A L Analog Input/Output Module
  • GE UCSC H1 IS420UCSCH1A-F-VO.1-A Controller Module
  • GE UCSC H1 IS420UCSCH1A-B Communication Processing Module
  • GE IC697VDD100 Digital Input Module
  • GE V7768-320000 3509301007768-320000A0 Controller Module
  • GE IS410TRLYS1B Relay Output Module
  • GE IS415UCVGH1A V7666-111000 VME Control Card
  • GE IC800SSI216RD2-CE servo motor controller
  • GE VMIVME-5565-010000 332-01565-010000P Reflective Memory
  • GE IC695ALG508-AA Analog Input Module
  • GE IC660EPM100J Power Monitoring and Control Module
  • GE RS-FS-9001 362A1052P004 Redundant Fan System Module
  • GE IS220UCSAH1AK independent processor module
  • GE 369-HI-0-M-0-0-0-E Motor Management Relay
  • GE CIFX50-C0 interface board
  • GE SR469-P5-H-A20-T Motor Management Relay
  • GE WES5120 2340-21005 power module
  • GE WES5120 2340-21003 Control Module
  • GE D20MIC10BASE-T 820-0756 Ethernet Module
  • GE WES13-3 5167-001-0210 Mechanical Relay Output Module
  • GE WES13-3 2508-21001 Control Board Module
  • GE D20ME 526-2005-216943 Input/Output Module