ABB ACV 700 Series Inverter
Functionality of the basic units 07 KT 97
User program 480 kB
User data 256 kB (Flash EPROM)
Digital inputs 24 in 3 groups of 8 each, electrically isolated
Digital outputs 16 transistor outputs in 2 groups of 8 each, electrically isolated
Digital inputs/outputs 8 in 1 group, electrically isolated
Analog inputs 8 in 1 group, individually configurable to 0...10 V, 0...5 V, +10 V, +5 V, 0...20 mA,
4...20 mA, Pt100 (2-wire or 3-wire), differential inputs, digital inputs
Analog outputs 4 in 1 group, individually configurable to 0...10 V, 0...20 mA, 4...20 mA
Serial interfaces COM1, COM 2 as MODBUS interfaces and for programming and test functions
Parallel interfaces for
connection of couplers 07 KP 90 (RCOM), 07 KP 93 (2 x MODBUS), 07 MK 92 (freely programmable)
System bus interface CS31
Integrated couplers see next page
High-speed counter integrated, many functions configurable
Real-time clock integrated
SmartMedia Card memory medium for operating system, user program and user data
LED displays for signal conditions, operating statuses and error messages
Power supply voltage 24 V DC
Data backup with lithium battery 07 LE 90
Programming software 907 AC 1131
Main features
· 24 digital inputs with LED displays
· 16 digital transistor outputs with LED displays
· 8 digital inputs/outputs with LED displays
· 8 individually configurable analog inputs 0...10 V,
0...5 V, ±10 V, ±5 V, 0...20 mA, 4...20 mA, differential
inputs, Pt100 (2-wire or 3-wire), the analog inputs are
also individually configurable as digital inputs
· 4 individually configurable analog outputs ±10 V,
0...20 mA, 4...20 mA
· 2 counters for counting frequencies up to 50 kHz, con-
figurable in 7 different operating modes
· 1 CS31 system bus interface for system expansion
· 1 interface for connecting communication modules
(e.g. 07 KP 90)
· 2 serial interfaces COM1, COM2
– as MODBUS interfaces and
– for programming and test functions
· Real-time clock
· LEDs for displaying operating conditions and error
messages
· Detachable screw-type terminal blocks
· Fastening by screws or by snapping the device onto a
DIN rail
· The lithium battery 07 LE 90 can be put into the
battery compartment in order to
– store and backup the user program in the RAM
– store and backup data which is additionally con-
tained in the RAM, e.g. the status of flags
– backup the time and date (real-time clock)
· RUN/STOP switch for starting and aborting the pro-
gram execution
· Extensive diagnosis functions
– self-diagnosis of the basic unit
– diagnosis of the CS31 system bus and the
connected modules
· Integrated Flash EPROM for storing program and data
· Exchangeable SmartMedia Card 07 MC 90 for user
data or for updating the operating system or PLC pro-
gram
2.1.1.2 Project planning / start-up
The following has to be observed for project planning and
start-up:
· Programming
is performed with AC31 programming software, which
can be run on commercially available IBM compatible
PCs (see documentation of the programming system
907 AC 1131).
· Online program modification
A quick modification of the user program is possible
without interrupting the operation (see programming
system 907 AC 1131).
· Possible operating modes
– Stand-alone basic unit
– Bus master basic unit
– Slave basic unit
· Backup of data areas,
i.e. saving of data during power OFF/ON, is possible
with an integrated battery and/or
by storing them in the Flash EPROM.
The basic units of this intelligent decentralised automation system: 07 KT 95, 07 KT 96, 07 KT 97 and 07 KT 98 are available in four models, which differ in their performance and functional configuration.
Differences in the number of digital and analogue I/Os: the 07 KT 95 has 12 digital inputs, 8 digital outputs, 4 analogue inputs and no digital I/O ports; the 07 KT 96 has 24 digital inputs and 16 digital outputs but no analogue inputs; the 07 KT 97 and 07 KT 98 both have 24 digital inputs, 16 digital outputs, 8 digital I/Os, the 07 KT 97 has 8 analogue inputs and the 07 KT 97 has 8 analogue inputs. Both 07 KT 97 and 07 KT 98 have 24 digital inputs, 16 digital outputs, 8 digital inputs/outputs, 07 KT 97 has 8 analogue inputs and supports Pt100, 07 KT 98 is the same as 07 KT 97 in terms of analogue inputs.
Difference in processing time: Typical processing time for 1kB programme is 0.3ms for 07 KT 95, 07 KT 96 and 07 KT 97 and 0.07ms for 07 KT 98, 07 KT 98 is faster.
Differences in integrated functions: The different models are available in several versions with different integrated internal couplers. For example, the 07 KT 97 is available with different combinations of ARCNET, PROFIBUS - DP, Ethernet, CANopen, etc., while some versions of the 07 KT 95 and 07 KT 96 have similar integrations, but in different combinations than the 07 KT 97.