Yokogawa AQ1000 OTDR Optical Time Domain Reflectometer

Core functions of the device

As an OTDR device, AQ1000 is primarily used to detect fiber optic fault locations, monitor transmission losses, fusion losses, and other parameters. Its main functions are as follows:

1. Optical pulse measurement function

Support two core measurement modes to meet different scenario requirements:

Average Measurement

TRACE mode: After multiple measurements, take the average of the data and display the results in waveform form to improve the signal-to-noise ratio. It can detect weak events that are masked by noise, such as fusion losses and reflections.

MAP mode: After completing the average measurement, the OTDR waveform is automatically analyzed, and various events (such as fusion points and bending points) are marked with icons. If the qualified/unqualified judgment conditions are preset, the judgment results will be displayed in the color of the icon.

Key feature: Supports one-time measurement of dual wavelengths of 1310nm and 1550nm (multi wavelength measurement). During measurement, the average measurement is completed at 1310nm first, and then automatically switches to 1550nm measurement.

Real time measurement

Only supports TRACE mode, with real-time waveform updates and displays during the measurement process. It can monitor events such as fusion loss and return loss in real time, as well as observe waveform changes when parameters such as wavelength, distance range, and pulse width change.

Limitation: Cannot be performed in MAP mode, it will automatically switch to TRACE mode after starting real-time measurement.

image.png

2. Data display and analysis function

The data shows

TRACE mode: The horizontal axis represents distance and the vertical axis represents loss level, displaying the waveform of optical pulse measurement. The waveform can be scaled and moved, and detected losses or reflections (referred to as "events") will be marked on the waveform.

MAP mode: Display all events from the measurement starting point to the fiber optic endpoint in order using icons, label the event type (such as fusion, bending, splitter) and distance from the starting point, and visually present the status of the fiber optic line.

data analysis

Waveform analysis: Measure the distance between two points, fusion loss, and return loss (inter marker return loss) through the cursor and markers.

Event analysis: Automatically detect events and display them on the screen (TRACE mode marked on the waveform, MAP mode displayed with icons), support event editing (insert/delete events, insert/delete distance reference point R), adjustable event detection conditions (such as fusion loss threshold, return loss threshold).

3. Pass/Fail Judgment

Judgment logic: Set a threshold for each measurement item. If the measurement value does not exceed the threshold, the event is judged as "Pass", and if it exceeds the threshold, it is judged as "Fail".

Judgment items: including connector loss, fusion loss, return loss, loss per kilometer between events (dB/km), and total loss.

The results show that in TRACE mode, qualified events have no special markings, while unqualified events are marked in red; In MAP mode, different colored icons are used to distinguish between them. The top progress bar is green when all events are qualified, and red when there are unqualified events.

4. Light source and power detection function

Stable Light Source

Transmit measurement light (continuous CW or modulated CHOP) from the OTDR port, with a wavelength consistent with the OTDR light pulse wavelength (1310nm/1550nm), for measuring optical loss or identifying optical fibers.

Visible light source (/VLS option)

Only supported by VLS option devices, emitting 650nm visible light (CW or 2Hz modulated CHOP) from the VLS port for visual inspection of fiber breakpoints and checking the core of multi-core fibers.

Power checker

Detect the presence of communication light (in use fiber) in the measured optical fiber through the OTDR port and check its power value. The supported wavelengths for measurement include 1310nm, 1490nm, 1550nm, 1625nm, and 1650nm.


5. Data storage and transmission function

File type and purpose

Characteristics of file format usage

. SOR stores the measurement results of optical pulses (including measurement/analysis conditions, waveform data, and event list data), which can display waveforms and event analysis results after loading. It only supports SOR files generated by AQ1000 devices

PDF stores the waveform data of the current screen or saved files in a report format. The report can be customized to include items such as job information, link summaries, and waveform diagrams

CFG storage system settings (devices, connections, etc.) can be used for unified configuration of multiple AQ1000 devices

. BMP/. JPG storage device screen images are only for viewing on a computer and cannot be loaded back into AQ1000

SOZ stores multiple waveforms measured simultaneously and only supports loading with AQ1000. When using AQ7933 OTDR simulation software for PC analysis, it needs to be split into SOR files

storage medium

Internal memory: Approximately 480MB, non removable, used for storing files and system files (such as the ACKUP and USERS-MANUAL folders).

USB storage medium: Supports USB 1.0/1.1/2.0 standard USB devices (Type A ports), which can store waveform data, measurement conditions, etc; The Type B Micro-B port can connect the device as a high-capacity storage device to a computer and operate internal files.

6. System auxiliary functions

Power saving mode: can set screen brightness (4 levels, including off), distinguish between battery powered and USB-AC adapter powered brightness; Support automatic sleep mode. After the device is turned on and there is no operation for the set time (1/5/10/30 minutes), it will automatically enter sleep mode. If there is no operation for 2 hours, it will automatically shut down.

Language and Display Settings: Supports multi language switching, and can set the initial screen (TRACE/MAP/Setup Info.) and screen color (Color 1/Color 2/Black and White) for startup.

Firmware update: Store the new firmware on a USB storage medium and connect it to the Type A port to update the device firmware.

image.png

Operation process (core scenario)

1. Average measurement (TRACE mode)

Mode switching: Click the TRACE/MAP button to ensure that the data is displayed in TRACE mode (the button displays as MAP).

Parameter settings: Click the Wavelength button to select the wavelength (1310nm/1550nm/1310nm+1550nm), set the distance range (automatic AUTO or manual, such as 200m-256km), and pulse width (automatic AUTO or manual, 3ns-20 μ s).

Start measurement: Press the AVG button, and the average measurement duration and laser on indicator will be displayed at the top of the screen. After the measurement is completed, it will automatically stop and perform event analysis, displaying waveforms and event results; Press the AVG button again to stop the measurement midway.

Data saving: Click on the floppy disk icon to save directly (in SOR/PDF/SOR+PDF format), or enable automatic saving in OTDR settings to automatically save data after measurement is completed.

2. Real time measurement (TRACE mode)

Parameter settings: Same as average measurement, select wavelength, distance range, pulse width (automatic or manual).

Start measurement: Press the REAL TIME button to activate the laser display and update the waveform in real-time; Press the REAL TIME button again to stop the measurement.

Data manipulation: During measurement, the cursor (displayed by clicking on the waveform position, dragging or clicking to move) and markers can be manipulated, and the current waveform data can also be saved (recording the waveform at the current time when saving).

3. Event analysis (TRACE mode)

Perform analysis: Press the MENU button and click the EVENT Analysis button. The device will automatically analyze the waveform and display the event (after averaging the measurements, it will be automatically executed without manual operation; when performing real-time measurements or loading real-time measurement SOR files, manual execution is required).

Result view: Information such as event number, distance, fusion loss, return loss, and event type is displayed in three forms: List, Separate, and All. You can click on the corresponding label to switch.

Event editing: Click on the waveform display area, the cursor will appear and the event editing interface will pop up. You can insert events (move the cursor to the target position and click the insert button), delete events (move the cursor to the event ▲ mark and click the delete button), and insert/delete distance reference point R.

4. Setting of qualified/unqualified judgment

Enter Settings: Press the MENU button, click OTDR Setup, and in the Setup Info. menu, click on the EVENT ANALYSIS area to enter the EVENT ANALYSIS SETUP screen.

Enable Judgment: Click the Pass Fail Judgment button and set it to ON.

Threshold setting: Set the threshold for each judgment item (such as connector loss ≤ 1.00dB, fusion loss ≤ 0.10dB, return loss ≥ 70dB, etc.).

View result: After the average measurement is completed, the unqualified events in the event list are highlighted in red, and the progress bar at the top of the TRACE mode displays the overall judgment result (green/red).


Data management

1. USB storage media operation

Connection and detection: Supports hot swapping, connects USB storage media (Type A port) when the device is turned on, and the device automatically detects it; When connecting, it is necessary to directly plug into the port without using a USB hub, and avoid frequent plugging and unplugging in a short period of time (with an interval of ≥ 10 seconds).

Data reading and writing precautions: When the USB storage medium access indicator light flashes or data is read or written, the medium cannot be removed or turned off, otherwise it may damage the medium or data; Only supports FAT format USB devices, does not support encrypted or protected USB devices.

2. Data saving and loading

Data saving: Press the MENU button, click the Save button, select the storage medium (internal memory/USB), file format (SOR/SOZ/SOR+JPG), set the file name, and save; Support automatic saving, enable Auto Save in OTDR settings, select the save mode (by date/custom User Define) and storage path.

Data loading: Press the MENU button, click the Load button, select the storage medium and target file (SOR/CFG/SOZ/PDF), the corresponding data will be displayed after loading the SOR/SOZ/CFG file, and the content will be viewed through a PDF viewer after loading the PDF file.

3. Report generation

Single file report: Press the MENU button, click the Report button, select the SOR file that needs to generate the report, set the report content items (such as job information, link summary, waveform diagram), and generate a PDF format report.

Multi file report: Press the MENU button, click the File button, select multiple SOR files, click the export report icon, and batch generate PDF reports.


System settings (key items)

1. OTDR settings (measurement related)

Measurement settings: including wavelength, distance range, pulse width, average duration (automatic or manual, 5-30 minutes), automatic save (ON/OFF), in use fiber alarm (ON/OFF, detecting the presence of communication light in the fiber to avoid affecting communication), connection check (ON/OFF, prohibiting OTDR port from emitting light when the fiber is not properly connected).

Event Analysis Settings: Set event search criteria (fusion loss threshold 0.01-9.99dB, return loss threshold 20-70dB, fiber endpoint threshold 3-65dB, whether bending loss is detected), pass/fail judgment (ON/OFF and threshold for each judgment item), and transmit fiber settings (ON/OFF, set the length of the transmit fiber to eliminate the influence of near end blind spots).

Analysis settings: Set the refractive index (IOR, 130000-179999, default 1.46000), backscatter level (1 μ s pulse width: -10.00 to -64.99dB; 1ns pulse width: -40.00 to -94.99dB), and mark the approximate method (LSA least squares method/TPA two-point method).

2. File settings

File Name Setting: Select the file name components (wavelength, comments, company name, fiber ID, etc.), set the tape number type (OFF or a-b to a-h), delimiter (such as _,~), and ID number (0-9999).

Report settings: Check the contents included in the report (such as job information, link summary, MAP chart, TRACE waveform, event list, etc.).

Label setting: Fill in fiber related information (company name, fiber type, cable ID, starting/ending position, etc.), which will be saved with the SOR file for easy traceability.

3. System settings

Power management: Set the screen brightness (Bright/Normal/Power Save/OFF) and automatic sleep time when powered by the battery/USB-AC adapter.

Network settings (/WLN options): Supports access point mode (AP) and station mode (Station), sets SSID, encryption type (WPA2-PSK), password, IP address, subnet mask, etc., can remotely control devices or transmit data through wireless LAN.

Restore factory settings: Select "Setup" to reset settings only (without deleting internal memory files), or select "All" to reset settings and delete all files in the USER folder except for the user manual (the BACKUP folder will be rebuilt to its default state).


Wireless LAN usage (/WLN option)

1. Network configuration

General settings: Press the MENU key → System Setup → Network Setup → Common Setup, set the username (default anonymous) and password for wireless connection authentication.

Access Point Mode (AP): Set SSID (such as AQ1000_TEMP01), encryption type (WPA2PSK), password, broadcast channel (AUTO or 1-11ch), IP address (such as 192.168.0.2), subnet mask (255.255.255.0), DHCP allocation starting address (such as 192.168.0.100), with the device as the access point and wireless terminals directly connected.

Workstation mode: Select a fixed SSID (manually entered or selected from a list of detected access points), set a password, DHCP (automatically obtained or manually set IP), and connect the device as a workstation to the existing wireless LAN.

2. Data transmission and remote control

Data transmission: Press the MENU button → System Setup → WLAN application, click OTDR Data Transporter, the device enters standby mode, the wireless terminal (such as a mobile phone) connects to the corresponding SSID, starts the OTDR Data Transporter software (needs to be downloaded from Yokogawa official website), and the data in AQ1000 can be transmitted.

Remote control: Click on OTDR Remote Controller, the device enters standby mode, the wireless terminal (PC/phone) connects to SSID, and controls the device through Yokogawa OTDR Remote Controller software or browser (enter device IP address), supporting control mode (can operate device, download files) and view mode (only view screen, download files).

Maintenance and upkeep

1. Daily inspection and cleaning

Mechanical inspection: After power failure, check the appearance of the equipment for any damage or deformation, ensure that the switches, connectors, and screws are not loose, and that the switches and moving parts operate smoothly; After powering on, check that the startup screen is normal, the buttons can switch screens, and the touch screen operation is sensitive.

Cleaning:

External device: Power off and disconnect the USB-AC adapter, wipe with a wrung out damp cloth, and avoid chemicals such as diluents, benzene, and alcohol to prevent deformation and fading.

Optical adapter and fiber end face: After turning off the power, open the light source port cover, remove the optical adapter (unscrew the M2 screw), wipe the fiber end face with a lint free and residue free lens cleaner, clean and reinstall the adapter (tightening torque of about 0.12N-m).

2. Troubleshooting and Error Handling

Common troubleshooting:

Troubleshooting and Solutions for Malfunctions

Check the USB-AC adapter connection (plug, power cord, DC plug) for no display during startup; Charge the battery and confirm that the POWER LED is on; Press and hold the power button for 2 seconds to force startup; If the backup files are damaged due to abnormal shutdown, long press the MENU button and press the power button until the device starts up

Screen automatically turns off to check battery level (low battery automatically shuts down); View power-saving mode settings (automatic sleep mode after no operation for the set time)

Touch screen unresponsive. Remove gloves and operate with bare hands; If there is still no response, restart the device or restore the factory settings

Error code handling: When the device displays an error code, refer to section 10.2 of the manual. For example, code 510 (PLUG CHECK Error) requires checking or cleaning the connector, and code 902 (low battery level) requires charging or replacing the battery; Hardware faults such as code 505-508 and 939-948 require contacting a Yokogawa dealer for repair.

3. Storage and consumables replacement

Storage conditions: After cleaning the equipment, it should be stored in an environment with stable temperature/humidity, no direct sunlight, minimal dust, and no corrosive gases; When not in use for a long period of time (≥ 1 month), store the battery in an environment of 10-30 ℃ after charging to avoid overdischarging.

Consumables replacement cycle:

Suggested replacement cycle for component names

The actual lifespan of the battery after 500 charging cycles is affected by the usage environment and cannot be replaced by oneself. It is necessary to contact the dealer

Backup battery (lithium battery) needs to be replaced at Yokogawa factory for 5 years

The LCD screen needs to be replaced at the Yokogawa factory after approximately 30000 hours

Ferrule plugs need to be replaced at Yokogawa factory every year

Universal adapter needs to be repurchased after 1 year

USB port needs to be replaced at Yokogawa factory after 1500 insertions and removals

4. Calibration and scrapping

Calibration cycle: It is recommended to conduct regular calibration once a year to ensure stable equipment performance and detect faults early.

Equipment scrapping: The equipment contains lithium-ion batteries and cannot be disassembled by oneself. It is necessary to contact the Henghe distributor and dispose of it according to relevant regulations.

image.png

  • ABB UNS4681V511 3BHE004074R0511 Expansion Unit Module
  • ABB PFTL101B 10KN 3BSE004197R1 high-performance weighing sensor
  • ABB CI532V02 3BSE003B27R1 Communication Module
  • ABB COM0034 control module
  • ABB 216VC626/P1000 HESG324442R112 processor unit relay card
  • ABB 216MB66 HESG324510M1 PLC Memory Expansion Module
  • ABB SPAJ140C overcurrent and ground fault relay
  • ABB DI840 3BSE020836R1 Digital Input Module
  • ABB AI845 3BSE023675R1 Analog Input Module
  • ABB B5LA HENF327886R0001 DC power module
  • ABB P7LA HNEF105323R0002 High Performance Control Module
  • ABB PPC322AEV01 HIEE300697R1 excitation control board
  • ABB REF620C_F NCFNAAAAABC2DNN1XF Feeder Protection and Control
  • ABB P72140-4-0788740 CTI21-P Input/Output Module
  • ABB DYTP123A 61430001-TW Ethernet Connection Module
  • ABB DYSF118B 61430001-XG Communication Interface Module
  • ABB DYPS154C 61430001-YP Serial Communication Module
  • ABB DTCC901B 61430001-FU Ethernet Communication Module
  • ABB SB510 3BSE000861R1 Backup Power Supply 110/230V AC
  • ABB CI535V26 3BSE022161R1 Communication Interface Module
  • ABB RAO02 redundant analog output module
  • ABB RAI02J redundant analog input module
  • ABB 1MRK002133-ABr02 analog-to-digital module
  • ABB UNITRAL1010 3BHE035301R0004 voltage regulator
  • ABB 3BHB019265R0410 Analog Input/Output (I/O) Module
  • ABB UNC4672AV1 HIEE205012R1 multi-functional input/output analog module
  • ABB REC650 1MRK008514-CB multifunctional circuit breaker
  • ABB RER 103 bus connection module
  • ABB REF545KB133AAAA High Performance Protection Relay
  • ABB REC670 1MRK002814-AC High-Performance Relay Module
  • ABB DASD001 3ASC25H241 Industrial Digital Input Module
  • ABB RED670 touchpad film
  • ABB NTAC-02 fiber optic cable
  • ABB XVC768AE102 3BHB007211R0102 Analog Input Module
  • ABB AD02 multi-channel integrated I/O module
  • ABB TU842 3BSE020850R1 module terminal unit
  • ABB APBU-44C 64669982 High Performance Controller Module
  • ABB REM611 panel
  • ABB RED615 panel
  • ABB L003748-AR 3BSX108237R300 Voltage Regulating Control Module
  • ABB COM0034 2RCA023019A0004C control module
  • ABB REU615E-D HBUAEAADNCA1BNN1XD Voltage Protection and Control Relay
  • ABB S-113H 3BHB01808R0003 Hydraulic Control Module
  • ABB REU615 panel
  • ABB TB840A 3BSE037760R1 modular cluster modem
  • ABB XVC770BE102 3BHE02103R0102 Controller Module
  • ABB LTC391AE01 HIEE401782R0001 Interface Module
  • ABB XVC770AE 3BHE006414R0001 fieldbus control system multifunctional module
  • ABB XVC768101 3BHB007211R101 Controller Module
  • ABB PM858-C 3BSE093350R1 Process Control System Module
  • ABB UAC389AE01 HIEE30088R0001 module controller
  • ABB AI02J high-performance I/O module
  • ABB IC698CPE030/IC698CPE020 series battery cover
  • ABB KSD211B 3BHE022455R1101 Input Coupling Unit ICU
  • ABB DSCA190V 57310001-PK Communication Processor
  • ABB GFD563A102 3BHE046836R0102 Analog I/O module
  • ABB XVC768115 3BHB007211R115 Industrial Control Module
  • ABB AI815 3BSE052604R1 I-O Module
  • ABB 5SGY3545L0010 3BHB006485R0001 Controller Module
  • ABB DAPI100 3AST000929R109 Ethernet Communication Interface Module
  • ABB SYN5201A-Z,V277 3BHB006714R0277 Auto single channel Syn
  • ABB KUC755AE117 3BHB005243R0117 System Controller
  • ABB CMA130 3DDE300410 Display Front Panel
  • ABB 07DC92D GJR525220R0101 Digital I/O Module
  • ABB PCD237A101 3BHE028915R0101 excitation control module
  • ABB CI627A 3BSE017457R1 Communication Interface
  • ABB 5SHY4045L0004 3BHB021400R0002 3BHE039203R0101 GVC736CE101 thyristor IGCT
  • ABB SYN5202A Controller Module
  • ABB LWN2660-6E 3BHL000986P7002 Power Conversion Module
  • ABB PFCA401SF 3BSE024387R4 Control Unit
  • ABB HIEE401807R0001 Advanced Power Electronics Module
  • ABB VBS01-EPD High Performance Digital Signal Processing Module
  • ABB LWN2660-6EG 3BHL000986P7002 Industrial Control Module
  • ABB SYN5201A-Z 3BHB006714R0217 Hydraulic Servo Module
  • ABB SYN5200a-Z,V217 SYNCHROTACT5 3BHB006713R0217 Dual channel synchronization device
  • ABB SAM3.0 Surge Arrester Monitoring System
  • ABB UNITROL 1005-0011 ECO 3BHE043576R0011 Automatic Voltage Regulator
  • ABB 3BHE032025R0101 PCD235B101 Exciter Control Module
  • ABB 3BHE006373R0101 XVC769AE101 INVERTER MODULE
  • ABB UFC765AE102 3BHE003604R0102 High-Performance PC Board
  • ABB 3BHE004573R0143 UFC760BE143 INTERFACE BOARD
  • ABB KUC720AE101 3BHB003431R0101 3BHB000652R0101 Controller Module
  • ABB HIEE300927R0101 UBC717AE101 High Voltage Inverter Board
  • ABB UFC721AE101 3BHB002916R0101 PC Board
  • ABB 5SHY4045L0003 3BHB021400 3BHE019719R0101 GVC736BE101 Diode and grid drive circuits
  • ABB 3BHE019719R0101 GVC736BE101 IGCT Module
  • ABB REM620A_F NAMBBABA33E5BNN1XF Protective Relay
  • ABB PPD113B03-26-100110 3BHE023584R2634 Power Distribution Module
  • ABB MB810 Module Mounting locations
  • ABB 3BHL000986P7000 LXN1604-6 POWER SUPPLY
  • ABB VBX01BA I/O Control Module
  • ABB AI03 AI module, 8-CH, 2-3-4 Wire RTDs
  • ABB 1TGE120010R1300 Industrial Control Module
  • ABB 216BM61b HESG448267R1021 Advanced Process Control Module
  • ABB BDD110 HNLP205879R1 Digital I/O Module
  • ABB IEMPU02 Power Supply Module
  • ABB G3FE HENF452697R1 High performance control module
  • ABB G3FD HENF452692R1 High-Performance Industrial Control Module
  • ABB B5EC HENF105077R1 Electronic Motor Protection Relay
  • ABB G3EFa HENF450295R2 Industrial Automation Module
  • ABB B5EEd HENF105082R4 Electronic Motor Protection Relay
  • ABB O3EId HENF452777R3 Digital Output Module
  • ABB NWX511a-2/R HESG112548R12 Industrial Automation Module
  • ABB E3ES Power communication module
  • ABB O3EX HENF315845R2 Industrial Control Module
  • ABB O3EHa HENF315087R2 Digital Output Module
  • ABB E3ED High-Performance Industrial Controller
  • ABB O3EGb HENF315118R2 Digital Output Module
  • ABB O3ED Digital Input Module
  • ABB O3ES HENF445789R1 Digital Input Module
  • ABB G3ESa HENF318736R1 control module
  • ABB 8025-235 Industrial Control Module
  • ABB 216NG61A HESG441633R1 HESG216875/K main control board
  • ABB SCYC51020 58052582G programmable Logic Controller
  • ABB RED670 Line differential protection
  • ABB PP825A 3BSE042240R3 Touch Screen Panel
  • ABB SCYC51020 58052582/G pulse trigger board
  • ALSTOM COP232.2 VME A32/D32.029.232 446 Controller Unit
  • ABB AO2000 LS25 Laser analyzers
  • ABB LM80 Laser level transmitter
  • ABB PM803F 3BDH000530R1 Base Unit 16 MB
  • ABB SD822 3BSC610038R1 Power Supply Device
  • ABB PCD235B1101 3BHE032025R1101 Industrial Control Module
  • ABB AZ20/112112221112E/STD Control Module
  • ABB UAD142A01 3BHE012551R0001 Industrial Control Module
  • ABB 5SHY35L4503 3BHB004693R0001 3BHB004692R0002 5SXE01-0127 main control board
  • ABB FET3251C0P184C0H2 High-Performance Power Module
  • ABB CAI04 Ability ™ Symphony ® Plus Hardware Selector