In terms of maintenance, the chassis, cooling vents, cables, and connectors should be checked monthly. Turn off the power during cleaning, use a dry soft cloth, and if necessary, slightly wet water or isopropanol. Do not allow liquids to enter the connector. Internal high voltage may still exist after a power outage, and maintenance must be carried out by qualified personnel.
FAQ
What is the relationship between Ndrive HPe and HPe 10/20/30?
HPe is the series name, HPe 10/20/30 refers to different power levels. HPe 10 has a peak value of 10 A and a continuous value of 5 A; HPe 20 is 20 A/10 A; HPe 30-S is 30 A/10 A and comes with internal shuts.
Does HPe support rotation?
Support, select - RDP option, provide single/dual channel, 10/7.5/5 kHz carrier frequency, and can output encoder simulation signal.
Can HPe's PSO and - MXH be used simultaneously?
HPe's MXH is compatible with PSO and real-time output, but attention should be paid to the tracking rate limitation and MXH delay of multi axis PSO.
How to choose - S and - EXTSHUNT?
-S is an internal 50 Ω, 40 W continuous, 400 W peak for 5 seconds shutdown; -EXTSHUNT is an external shut-down connection, suitable for larger regenerative energy. The two are mutually exclusive. First, calculate the regenerative energy and peak power.
Can HPe directly replace other brands of servo drives?
It cannot be judged solely based on current and size. It is necessary to verify the motor type, feedback, commutation, FireWire network, I/O, PSO, ESTOP, and regeneration processing.
What absolute encoders does HPe support?
Supports protocols such as EnDat and Resolute to read location and fault information through serial data streams.