The Rexroth Indramat NAM1.2-08 is an AC servo line former, identified by the R911246505 reference. In Indramat drive systems, the line former provides the AC line connection structure for the drive lineup. It handles the incoming supply, the protective elements, and the connection to the drive modules, and it must be matched to the total drive power and to the supply conditions of the machine.
This article provides a technical overview for drive engineers, panel builders, commissioning teams, and maintenance personnel. It covers the line former role in the drive system, cabinet integration, supply and protection planning, wiring practice, commissioning checks, diagnostics, and lifecycle care. Exact supply data, current ratings, fuse data, terminal assignments, and approved accessories must be confirmed with the product documentation for this line former variant.
Role in the Drive System
The line former is the entry point of the AC supply into the drive lineup. It distributes the incoming power to the drive modules and provides the mounting position for the protective devices that protect the supply cables and the drive system. In some configurations it also carries the line rectifier function and the associated charging circuit for the DC bus.
Because the line former influences the supply of all connected drives, its rating must cover the total load of the lineup and the expected simultaneity of the axes. A line former that is too small will limit the available power or will cause protective devices to trip during acceleration. The lineup should be planned as a whole, with the line former, the drive modules, and the motor loads considered together.
Cabinet Integration
The line former is mounted in the control cabinet on the drive mounting plate. Clearance should be provided for the supply cables, the protective devices, and the ventilation of the lineup. The mounting position should allow access to the terminals and to the protective elements without dismantling the drive modules.
The cabinet should protect the unit from moisture, dust, and conductive contamination. Supply cables should enter the cabinet through suitable entries and should be strain relieved. The cable cross section should be selected for the current and for the voltage drop, and the protective earth connection should be sized according to the installation requirements.
Supply and Protection Planning
The supply concept should define the nominal voltage, the frequency, the short circuit capacity, and the type of earthing at the installation site. These values must fall within the permitted range of the drive system. If the supply is provided through a transformer or a generator, the additional impedance should be considered in the protection concept.
Protective devices such as fuses or circuit breakers should be selected according to the documentation for the lineup. The coordination between the supply protection and the internal protection of the drive modules should be checked so that a fault in one module does not disconnect the whole lineup unnecessarily. The protection concept should be documented in the cabinet drawing.
Wiring Practice
Wiring should follow the terminal assignment for the line former. Supply conductors, the protective earth conductor, and the connections to the drive modules should be tightened to the specified torque. Cable lugs should match the conductor cross section, and the connection points should be accessible for later inspection.
The cable routing inside the cabinet should keep the supply cables separated from the signal and communication cables. Shields of motor and feedback cables should be terminated at the cabinet entry or at the drive module as described in the installation instructions. All cables should be labeled so that the wiring can be restored after service work.
Commissioning Checks
Before power is applied, the installer should verify the supply voltage, the phase sequence where relevant, the protective earth connection, and the tightness of all terminals. The insulation of the supply cables should be checked, and foreign objects should be removed from the cabinet. The lineup should be inspected for correct module order and complete mechanical fixing.
After power is applied, the supply voltage should be measured at the line former terminals, and the charging of the DC bus should be observed. Any unusual noise, smell, or fault message should be investigated immediately. The commissioning record should note the measured values and the protection settings.
Diagnostics and Maintenance
Diagnostic work should consider the supply conditions, the protective devices, and the state of the connected drive modules. A tripped protective device may indicate a fault in a drive module, an undersized supply, or a short circuit in the wiring. The cause should be identified before the protection is reset.
Routine maintenance includes inspection of terminals for discoloration, checking of the protective devices, cleaning of dust accumulation, and verification of the cabinet ventilation. Qualified personnel should perform service work, and the supply should be isolated before connections are touched. For exact technical data and approved application conditions, the product documentation for this line former should be used as the final reference.