Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969
    ❤ Add to collection
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥22125.00
      ¥24175.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.670KG
    • Quantity:
    • (Inventory: 47)
Description
<span style="font-size: 18px; font-family: arial;">Rexroth DBETE-62/315G24K31A1V Valve R901029969</span>

Rexroth DBETE-62/315G24K31A1V Valve R901029969

A technical overview of the Rexroth DBETE-62/315G24K31A1V proportional pressure valve with the R901029969 reference.

The Rexroth DBETE-62/315G24K31A1V is a proportional pressure valve from the DBETE series, identified by the R901029969 reference. The model code describes the valve size, the pressure range, the solenoid voltage, the electrical connection, and the adjustment concept. The valve regulates the pressure in a hydraulic circuit according to an electrical command, so it is used where pressure must be varied during the machine cycle rather than fixed by a mechanical setting.

This article provides a technical overview for hydraulic designers, machine integrators, commissioning teams, and maintenance personnel. It covers the valve role in the hydraulic circuit, mechanical installation, electrical connection, pressure adjustment, diagnostics, and lifecycle care. Exact pressure range, flow data, solenoid data, and approved accessories must be confirmed with the product documentation for this valve variant.

Valve Role in the Hydraulic Circuit

A proportional pressure valve limits or regulates pressure according to an electrical command. The command is converted into a solenoid force that acts on the valve spool, so the regulated pressure changes continuously with the command signal. This allows the machine control to reduce pressure during a clamping phase or to increase it during a pressing phase without mechanical adjustment.

The DBETE series is used in circuits where the pressure must follow a profile during the cycle. The valve should be selected together with the pump, the actuator, and the amplifier so that the pressure range and the flow capacity match the application. A valve that is oversized for the flow can show poor resolution, while an undersized valve can limit the machine performance.

Mechanical Installation

The valve is mounted on a manifold block or on a subplate with the specified screws and torque values. The mounting surface should be flat and clean, and the port pattern must match the valve. The O rings should be checked for correct seating, and the tightening sequence should follow the instructions so that the valve body is not distorted.

The mounting position should allow access to the adjustment elements and to the electrical connector. The valve should be protected from mechanical damage and from excessive heat. The hydraulic fluid should be compatible with the sealing materials, and the fluid cleanliness should meet the requirement of the system.

Electrical Connection

The solenoid connection should follow the terminal or connector assignment for the valve variant. The supply voltage and the current range must match the amplifier output. The cable should be screened where the environment requires it, and the screen should be terminated according to the installation instructions.

The cable should be routed so that it is not exposed to hot surfaces or to continuous movement. The connector should be locked in place, and the cable should be supported so that its weight does not load the connector. The wiring should be labeled so that the valve function can be identified during service work.

Pressure Adjustment

Adjustment begins with the hydraulic system prepared and the machine in a safe state. The command signal should be set to zero, and the resulting pressure should be observed. The offset should be set so that the valve produces the intended minimum pressure at zero command. The gain should then be set so that the full command range covers the required pressure range.

After the basic settings, the pressure should be measured at several command values and compared with the machine specification. If the pressure does not follow the command, the hydraulic circuit, the amplifier, and the valve should be checked in sequence. The final settings should be recorded for the machine documentation.

Diagnostics

Diagnostic work should separate hydraulic and electrical causes. A valve that does not regulate may have a wiring problem, a faulty solenoid, a contaminated spool, or a supply issue. A valve that regulates unevenly may be affected by air in the fluid or by a worn spool. The amplifier settings should be reviewed together with the measured pressure before parts are exchanged.

When a fault occurs, the command signal, the supply voltage, the solenoid current, and the regulated pressure should be checked in a defined sequence. Power should be isolated before connectors are opened, and the hydraulic circuit should be depressurized before the valve is removed.

Maintenance and Lifecycle Care

Routine maintenance includes inspection of the valve mounting, the connector, the cable, and the hydraulic fluid condition. The adjusted values should be recorded so that they can be restored after service work. If the valve is replaced, the settings should be transferred and verified with the same test procedure that was used during commissioning.

The documentation of the valve, the amplifier, and the hydraulic circuit should be kept together. This record supports troubleshooting and helps maintain consistent machine behavior. Qualified personnel should perform service work, and the relevant safety instructions should be followed. For exact technical data and approved application conditions, the product documentation for this valve should be used as the final reference.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide