The Rexroth IKG0071-05.0m is a servo motor cable from the Indramat accessory range, supplied with a 5 meter length. The cable connects a servo motor to its drive and carries the motor power conductors together with the protective earth connection. The IKG designation identifies the cable family and the connector configuration, and it should be compared with the motor and drive documentation before a replacement cable is selected.
This article provides a technical overview for drive engineers, panel builders, commissioning teams, and maintenance personnel. It covers the cable role in the drive system, routing and bending practice, connector care, shielding and grounding, compatibility checks, and lifecycle planning. Exact conductor data, current rating, bending radius, and approved accessories must be confirmed with the product documentation for this cable variant.
Cable Role in the Drive System
In a servo axis, the motor cable is the electrical link between the drive output and the motor winding. It carries a switched output with steep edges, so the cable design and the shielding concept influence both the motor behavior and the electromagnetic compatibility of the machine. A cable that is too long, too thin, or poorly shielded can cause drive faults, motor heating, and interference with nearby signal cables.
The IKG0071-05.0m is intended for applications where the distance between the cabinet and the motor is moderate. The 5 meter length should be checked against the actual cable route, because the route through the machine often requires more length than the direct distance suggests. A cable that is stretched to reach the motor should be replaced by a longer variant rather than routed under tension.
Routing and Bending Practice
The cable should be routed away from signal and feedback cables where possible. Where the cables must cross, they should cross at a right angle to reduce coupling. The cable should not run parallel to motor cables of other axes over long distances, because the switched outputs can interact.
In a moving axis, the cable should be guided in an energy chain with the specified bending radius. The cable should be fixed at both ends so that the movement is taken up by the chain and not by the connector. Sharp bends at the cabinet entry and at the motor connector should be avoided, because these points are common locations for conductor damage.
Connector Care
The motor connector and the drive connector should be inspected before installation. Bent pins, contamination, and a damaged locking mechanism are reasons to replace the cable. The connector should be aligned before insertion and should not be forced. The locking ring should be engaged fully so that the connector cannot work loose during machine vibration.
The cable should always be disconnected by holding the connector body. Pulling on the cable can damage the internal conductors and the strain relief. When the cable is stored, the connectors should be protected with caps so that dust and moisture cannot enter.
Shielding and Grounding
The motor cable shield is part of the electromagnetic compatibility concept of the drive system. The shield should be terminated at the drive end according to the installation instructions, and the motor end should be connected to the motor housing through the connector. A shield that is connected only at one end, or that is connected through a long pigtail, provides little protection against interference.
The protective earth conductor in the cable must be connected at both ends. The earth connection should be checked with a continuity measurement after installation, because a loose earth connection is both a safety issue and a source of drive faults.
Compatibility Checks
The cable must match the motor and the drive. The conductor cross section must carry the motor current, and the connector type must fit the motor and the drive housing. A cable with a different pin assignment can damage the motor or the drive, so the documentation should be checked before a replacement is connected.
When a cable is replaced, the axis should be tested at low speed before production operation. The test should confirm that the motor direction, the feedback signal, and the brake behavior are unchanged.
Lifecycle Planning
Motor cables are wear items in a moving axis. The replacement interval should be planned from the cycle count and from the observed condition of the cable jacket and the connectors. Keeping a spare cable with the correct length and connector type reduces downtime when a fault occurs.
Routine maintenance includes inspection of the jacket, the connectors, the strain relief, and the earth connection. Qualified personnel should perform service work, and the drive should be isolated before the cable is disconnected. For exact technical data and approved application conditions, the product documentation for this cable should be used as the final reference.