The HMV02.1R-W0015-A-07-NNN is a utility unit within the Rexroth IndraDrive range. It provides the supply and auxiliary functions that support the operation of the drive system, including the DC link supply and the monitoring functions required by the connected drive modules. The W0015 segment identifies the 15 kW power class, and the utility unit is designed for mounting in an industrial control cabinet alongside the drive modules and the associated power components.
The utility unit converts the three-phase mains supply into the DC link voltage that supplies the drive modules. The DC link provides a stable intermediate voltage for the inverters, and it stores energy to smooth the rectified supply and to supply the transient current demands of the drives during acceleration. The utility unit includes the rectifier, the DC link capacitors, and the charging circuit that limits the inrush current when the system is switched on. The charging circuit protects the capacitors and the supply components from excessive current during the startup phase.
The utility unit monitors the mains voltage, the DC link voltage, and the load current. It detects abnormal conditions such as phase loss, overvoltage, and undervoltage, and it initiates a protective response when these conditions exceed the specified limits. The DC link voltage is regulated to maintain a stable supply for the drives, and the utility unit provides the diagnostic information that allows the control system to identify the cause of a fault.
The 15 kW power class defines the maximum continuous DC power that the utility unit can deliver to the drive modules. When sizing the unit, the total demand of the connected drives must be considered, including the simultaneous acceleration of multiple axes and the regenerative energy returned during braking. The common DC link architecture allows energy from braking axes to be absorbed by accelerating axes, which reduces the demand on the utility unit and improves the overall energy efficiency of the machine. The utility unit’s power class must be selected so that the DC link voltage remains within the permissible range under all operating conditions.
The utility unit includes the components required for the DC link precharge and the discharge when the system is switched off. The discharge circuit ensures that the DC link capacitors are discharged to a safe voltage within the specified time after the supply is removed, protecting personnel from electrical hazard during maintenance. The discharge function is monitored by the utility unit, and the status is reported to the control system.
The HMV02.1R-W0015-A-07-NNN is housed in a cabinet mounted enclosure that provides mechanical protection for the internal components. The enclosure includes the heat sink and the cooling arrangement required to dissipate the losses of the rectifier and the DC link components. The installation must respect the specified clearances to ensure adequate airflow and to avoid recirculation of heated air. The thermal monitoring in the utility unit reduces the output power when the temperature rises above the nominal range, protecting the components from overheating.
The utility unit’s terminals are arranged for connection to the three-phase supply, the DC link busbars, and the control interface. The busbar connection distributes the DC link voltage to the drive modules in the cabinet, and the busbar arrangement must be designed for the current levels of the drive system. The control interface provides the signals for the precharge, the discharge, and the status monitoring, and it connects the utility unit to the higher level control system.
The Rexroth HMV02.1R-W0015-A-07-NNN utility unit is used in IndraDrive systems that require a 15 kW DC link supply for multiple drive axes. Typical applications include packaging machinery, printing equipment, handling systems, and general automation equipment where coordinated motion and energy sharing across a common DC bus are beneficial. The utility unit’s role is to provide the electrical supply and the monitoring functions that support the drive modules, while the drive modules perform the motor control functions. As a member of the IndraDrive range, the utility unit follows the platform conventions for power rating, DC link supply, protection functions, and cabinet installation.