The HM 17-11/315-C/V0/0 is a hydraulic pressure sensor within the Rexroth HM series of pressure measurement devices. It is designed to measure the pressure in a hydraulic circuit and to convert this pressure into an electrical signal that can be read by a machine controller or a closed-loop regulation system. The 315 designation indicates the measurement range of the sensor, which covers pressures up to 315 bar. The sensor is used in industrial hydraulic systems where the pressure must be monitored continuously or where the pressure must be regulated as part of a closed-loop control function.
The pressure sensor uses a measuring element that deflects under the applied hydraulic pressure. The deflection is converted into an electrical signal by a strain gauge bridge or a similar sensing technology, depending on the sensor design. The electrical signal is proportional to the applied pressure, and it is conditioned and amplified by the sensor electronics to produce an output that is compatible with the machine control system. The sensor’s measurement range, output signal, and accuracy are defined by the type code, and the sensor is matched to the pressure range and the signal requirements of the application.
The sensor’s measuring element is exposed to the hydraulic fluid through a pressure port, and the electronics are isolated from the fluid by a diaphragm or a seal. The materials of the pressure port and the diaphragm are selected for compatibility with the hydraulic fluid and for resistance to corrosion. The sensor’s internal cavity is designed to avoid trapped air and to allow the pressure to be transmitted accurately to the measuring element.
The sensor provides an electrical output signal that represents the measured pressure. The output signal type and range are defined by the type code, and the signal is conditioned to match the input requirements of the machine controller or the drive system. The sensor electronics include amplification, filtering, and temperature compensation, so that the output signal remains accurate across the operating temperature range. The sensor’s zero point and span are calibrated during manufacturing, and the calibration data is stored in the sensor or in the associated documentation.
The electrical connection is made through the connector or the cable defined by the type code. The connection is protected against reverse polarity and short circuit, and the signal circuit is shielded to reduce the effect of electrical interference. The sensor’s output signal can be used for pressure display, for alarm and protection functions, and for closed-loop pressure regulation in the hydraulic system.
The sensor is installed in the hydraulic circuit with the pressure port connected to the point where the pressure is to be measured. The installation position must allow the pressure to be transmitted to the measuring element without trapped air, and the sensor must be accessible for service and calibration. The sensor housing and the pressure port are designed for the pressure rating of the hydraulic system, and the mounting arrangement must support the weight of the sensor and the connected cable.
The sensor’s pressure port threads and the sealing arrangement must be matched to the hydraulic connection to prevent leakage. The installation torque must be within the specified range to avoid damage to the thread or the sealing surface. The sensor’s electrical cable must be routed to avoid mechanical damage, excessive heat, and electrical interference from power cables.
The Rexroth HM 17-11/315-C/V0/0 pressure sensor is used in industrial hydraulic systems that require pressure measurement and monitoring. Typical applications include hydraulic power units, presses, injection molding machines, machine tools, and general hydraulic circuits where the pressure must be measured for control, display, or protection purposes. The sensor’s 315 bar measurement range covers the working pressures of many industrial hydraulic systems, and the electrical output allows the pressure signal to be integrated into the machine control architecture. As a member of the HM series, the sensor follows the product family conventions for measurement principle, electrical output, pressure connection, and installation.