In the field of micro torque precision assembly, Atlas Copco's MT Focus 6000 control and drive unit is designed to provide precise power and control for ETD, QMT and other micro torque tools, and is widely used in electronic, medical, aerospace and other occasions with high requirements for tightening quality. However, the safe operation of precision controllers highly relies on correct installation, strict electrical grounding, and standardized maintenance procedures. This article is based on official security information documents and systematically summarizes the key technical parameters, mandatory safety requirements, environmental conditions, installation specifications, and daily maintenance points of MT Focus 6000 from the perspective of engineering practice, providing a complete safety operation reference manual for on-site engineers.
Product positioning and core technical parameters
The MT Focus 6000 is a micro torque control and drive unit (applicable from serial number F8350001 onwards) with a rated output of 36/42V DC and a power of 400W, designed specifically for low torque, high-precision tightening applications. Its core compatibility tools include:
ETD MT21/41, ETD M ABL V2, QMT21/41, QMC21/41 (with 180W-36V power supply);
ETD MT61, ETD MC61, QMT61, QMC61 (with 252W-42V power supply).
This controller supports IP20 protection level and is suitable for indoor industrial environments, but must strictly follow installation and usage specifications to ensure safety and accuracy.
Environmental conditions and installation location requirements
The design of MT Focus 6000 ensures safe operation under the following environmental conditions:
Indoor use, altitude not exceeding 2000m;
Working temperature:+5 ° C~+40 ° C (+41 ° F~+104 ° F);
Storage temperature: -25 ° C~+60 ° C (-13 ° F~+140 ° F);
Relative humidity: 80% is allowed at a maximum of 31 ° C, and linearly decreases to 50% at 40 ° C;
The fluctuation of power supply voltage shall not exceed ± 10% of the nominal value;
Transient overvoltage does not exceed overvoltage category II;
Pollution level 2 (non-conductive pollution only);
Protection level IP20 (prevents solid foreign objects with a diameter of ≥ 12.5mm from entering, not waterproof).
Installation key point: The equipment must be placed in a location where the disconnect device (power plug) is easily accessible, in order to quickly cut off the power in case of emergency. Before transportation, all connecting cables must be disconnected and adequately insulated packaging must be used to prevent component damage.
Mandatory grounding - an unbreakable safety red line
3.1 Basic Grounding Requirements
This device must be grounded (Class I grounded device)! The grounding equipment must be plugged into a socket that is correctly installed and grounded according to relevant regulations. It is strictly prohibited to remove the grounding pin or modify the plug in any way, nor to use adapter plugs.
The core function of grounding: When an electronic fault or breakdown occurs in the device, grounding provides a low impedance path to guide the current away from the user, thereby protecting the operator's safety. The document clearly emphasizes: 'Should the equipment suffer electronic malfunctioned or broken down, the earth provides a low resistance path to charge electricity away from the user.'
3.2 Mandatory requirements for using certified cables
The document emphasizes that it is strongly recommended to use cables that have undergone safety testing provided with the product. It is prohibited to modify cables or use them for other purposes. When the cable is damaged, it must be replaced with a certified cable with the same electrical rating. The use of non certified cables may result in electric shock, fire, property damage or serious injury, and may affect or cancel the product's compliance certification.
3.3 Additional grounding requirements for welding operations
If welding operations are carried out simultaneously, the workpiece must be grounded separately. This is to prevent the return current from flowing through the grounding cable of the controller when the return wire of the welding equipment is not correctly installed on the workpiece. Atlas Copco suggested that the cross-sectional area of the grounding conductor should be at least as large as the return line of the welding equipment used.
Electrostatic Discharge (ESD) Protection - The Hidden Killer of Precision Controllers
The internal electronic components of MT Focus 6000 are highly sensitive to electrostatic discharge. All maintenance and repair work must be carried out in an ESD approved working environment. The document provides a typical ESD workstation example diagram (including grounding pads, wristbands, etc.). Neglecting ESD protection may result in hidden damage, intermittent faults, or permanent damage. Ensure that all service operations are performed on the ESD safety workbench.

Operational safety and work cycle limitations
5.1 Intermittent working system
The micro torque tool paired with MT Focus 6000 is designed for intermittent use. The typical work cycle is: 1 second run, 4 seconds stop. The actual acceptable working cycle depends on various factors such as torque size and joint type. The tool has built-in protection mechanisms to ensure that the allowed working cycle is not exceeded.
5.2 Operating Environment Limitations
Only for use in dry rooms;
Prohibited from use in explosive environments;
Must be operated by qualified professionals in an industrial assembly environment;
Ensure that the tool output head does not come into contact with conductors, concealed conductors, or live parts in the controller cable.
5.3 Remote Startup and Program Change Risks
Document warning: Using the remote boot feature may cause the tool to start unexpectedly. System troubleshooting and restart are only for authorized personnel to perform.
Regular inspection and maintenance standards
6.1 Cable Inspection
Regularly inspect power cables and tool cables. Once any signs of damage (wear, cuts, compression, etc.) are found, replace immediately. The consequences of using non certified cables have been emphasized earlier.
6.2 Cleaning Standards
Use only a damp cloth and water to clean the components;
It is strictly prohibited to use cleaning agents containing solvents;
Please contact Atlas Copco service technicians for specific cleaning suggestions.
6.3 Plug management
The method of unplugging the plug must ensure that the operator can check whether the plug remains unplugged from any accessible position, which is a basic safety measure to prevent accidental power on.
Calibration Certificate - Key to Traceability
The MT Focus 6000 controller has been calibrated before leaving the factory. Users can download the calibration certificate through the following steps:
visit https://webbox.atlascopco.com/webcert/index_microtorque.html ;
Enter the product's serial number in the "Serial no" search field;
Click on the file in the search results to open and download the certificate.
It is recommended to regularly verify the calibration certificate information to ensure that the controller accuracy meets the process requirements.
Compliance Statement and Material Information
8.1 EU Compliance
The MT Focus 6000 complies with the following regulations:
2011/65/EU (RoHS) and 2015/863/EU revisions;
2014/30/EU(EMC);
2014/35/EU(LVD)。
8.2 REACH and RoHS (China)
The product complies with China's RoHS requirements (see table on page 2 of the document for details). According to Article 33 of the REACH regulation, certain electrical and mechanical components in products may contain lead metal (CAS 7439-92-1) - which is a legal exemption under RoHS and will not leak or mutate during normal use. The lead concentration in the entire product is far below the threshold. California Proposition 65 warns of potential exposure to chemicals such as lead (see www.P65Warnings. ca. gov).
8.3 Disposal of WEEE
The product complies with the WEEE Directive (2012/19/EU) and is marked with a crossed wheel trash can symbol (with a single black line below), indicating the presence of components that require WEEE treatment. The entire product or related components can be sent to the customer center for processing.
8.4 FCC/IC Declaration
This device complies with FCC Part 15 and belongs to Class A digital devices, which may generate radio frequency interference in commercial environments. Indoor use only. Operating conditions: (1) Do not cause harmful interference; (2) Accept any interference received.
On site quick inspection checklist
Inspection item frequency execution method
Ground continuity: Measure the resistance from the controller casing to the main ground with a multimeter every month (<1 Ω)
Visually inspect the appearance of power cables for damage, compression, and cuts during each shift
Visually inspect the appearance of the tool cable every shift, paying attention to the plug location
ESD workbench status: Confirm the grounding pad and wristband connections are intact for each shift
Calibration certificate verification downloaded every six months and compared with equipment labels
Ventilation and temperature and humidity are confirmed quarterly to ensure that the environment is within the allowable range