Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Rexroth 2ma-1a P58718 Pilot Air Valve
    ❤ Add to collection
  • Rexroth 2ma-1a P58718 Pilot Air Valve

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥15127.00
      ¥16625.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.640KG
    • Quantity:
    • (Inventory: 46)
Description
<span style="font-size: 18px; font-family: arial;">Rexroth 2ma-1a P58718 Pilot Air Valve</span>

Rexroth 2ma-1a P58718 Pilot Air Valve

A technical overview of the Rexroth 2ma-1a P58718 pilot air valve for pneumatic control circuits.

The Rexroth 2ma-1a with the P58718 reference is a pilot air valve used in pneumatic control circuits. A pilot air valve uses a small control pressure or an electrical signal to switch a larger air flow, so it is often used to control cylinders, actuators, and larger directional valves in a machine. The valve designation and the P58718 reference should be compared with the machine documentation before installation or replacement.

This article provides a technical overview for pneumatic designers, machine integrators, commissioning teams, and maintenance personnel. It covers the valve role in the pneumatic circuit, mounting, air supply preparation, electrical connection, adjustment, diagnostics, and lifecycle care. Exact pressure range, flow data, port size, and approved accessories must be confirmed with the product documentation for this valve variant.

Valve Role in the Pneumatic Circuit

In a pneumatic system, a pilot operated valve allows a small control signal to switch a larger air flow. This arrangement is useful when the main valve must handle a large flow but the control signal comes from a small solenoid or from a manual pilot. The pilot stage reduces the force that the control element must produce, so the main stage can be compact while still providing a high flow capacity.

The pilot air valve should be selected together with the actuator and the main valve. The flow capacity, the response time, and the pilot pressure range must match the circuit. A valve that is too small for the flow will cause slow actuator movement, while a valve that is oversized may produce abrupt motion.

Mounting

The valve is mounted on a manifold or on a bracket with the specified screws and torque values. The mounting position should allow access to the pilot connection and to the main ports. The valve should be protected from mechanical impact, excessive heat, and water spray, and the exhaust ports should be arranged so that air can escape freely.

The port threads should be sealed with a suitable sealing element, and the tightening torque should follow the instructions so that the valve body is not distorted. The tubing should be supported so that its weight does not load the valve body.

Air Supply Preparation

Compressed air contains moisture, oil, and particles that can affect valve life. The air supply should be prepared with a filter and, where required, a regulator and a lubricator. The filter should be checked and drained according to the maintenance plan so that water does not reach the valve.

The pilot air should be clean and dry, because contamination in the pilot stage can block the small passages and prevent the valve from switching. The supply pressure should be within the range specified for the valve, and the pressure should be stable during the machine cycle.

Electrical Connection

Where the pilot stage is electrically operated, the solenoid connection should follow the terminal or connector assignment. The supply voltage and the current must match the solenoid data, and the cable should be routed away from moving parts and hot surfaces. The connector should be locked in place and should be protected against water ingress.

Where the pilot stage is pneumatically operated, the pilot line should be connected to the correct port and should be checked for leakage. The pilot pressure should be set according to the valve requirement, and the pilot line should be protected from kinks and sharp bends.

Adjustment and Commissioning

Commissioning begins with a check of the air supply, the electrical connection, and the mechanical installation. The valve should be tested at low pressure and with the actuator disconnected where possible. The switching behavior should be observed, and the response time should be checked against the machine requirement.

If the actuator moves too slowly, the flow capacity, the tubing size, and the exhaust path should be reviewed. If the valve does not switch reliably, the pilot pressure, the pilot signal, and the contamination of the pilot air should be checked.

Diagnostics and Maintenance

Diagnostic work should separate the valve from the actuator and from the air supply. A valve that does not switch may have a blocked pilot passage, a faulty solenoid, or insufficient pilot pressure. A valve that leaks may have a worn seal or a damaged seat. The cause should be identified before the valve is replaced.

Routine maintenance includes inspection of the air filter, the pilot line, the connectors, and the valve body. Leakage should be corrected, and worn seals should be replaced according to the maintenance plan. Qualified personnel should perform service work, and the air supply should be isolated and depressurized before the valve is removed. For exact technical data and approved application conditions, the product documentation for this valve should be used as the final reference.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide
  • Bosch Rexroth VT-MSPA Proportional Valve Amplifier Configuration and Troubleshooting Guide
  • Bosch Rexroth CDH1/CGH1/CSH1 Square Cylinder Selection and Compression Rod Verification
  • Bosch Rexroth CD/CG/CS Hydraulic Cylinder Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide
  • Bosch Rexroth MSK Servo Motor Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth IndraMotion MTX CNC System Selection and Backup Guide
  • GE MV3000 Inverter Cooling Fan Replacement and Upgrade Plan
  • Bosch Rexroth Indramat DIAX04 HDD/HDS Drive Controller Planning Guide
  • Technical Analysis and Selection Guide for Bosch Rexroth AZPF Gear Pump
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller