The Rexroth LTU350 is a three-phase servo amplifier designed for closed loop control of a servo motor in an industrial machine. The unit is associated with a 330 V class and a 10 A output range, which places it in the compact drive segment. The amplifier converts the incoming supply into a controlled three-phase output that drives the motor according to the command from the machine control.
This article provides a technical overview for drive engineers, panel builders, commissioning teams, and maintenance personnel. It covers the amplifier role in the axis, cabinet integration, supply and motor connection, feedback planning, commissioning, diagnostics, and lifecycle care. Exact supply data, output current, thermal requirements, and approved accessories must be confirmed with the product documentation for this amplifier variant.
Amplifier Role in the Axis
The LTU350 provides the power stage and the control electronics for a servo axis. It reads the command value from the machine control, evaluates the motor feedback, and adjusts the three-phase output so that the motor follows the commanded position, speed, or torque. The amplifier also monitors current, temperature, and communication state and reports deviations through diagnostic messages.
The 10 A output class suits small and medium axes in handling, packaging, and production equipment. The amplifier must be matched to the motor and to the load profile so that the thermal margin is sufficient and the control loop behaves stably.
Cabinet Integration
The amplifier is mounted in a control cabinet with clearance above and below the unit for airflow. Heat produced by the amplifier must be removed through the cabinet ventilation concept. The mounting position should allow access to terminals, connectors, and status indicators.
Power and signal cables should be routed separately. Motor cables should not run parallel with feedback cables over long distances. Protective grounding must be connected according to the installation instructions, and all terminals should be tightened and labeled.
Supply and Motor Connection
The supply connection should match the voltage and frequency range of the amplifier. The supply should be protected according to the installation concept, and the phase sequence should be verified where relevant. The motor connection must match the output rating and the motor winding.
The motor cable should be rated for the current and should be shielded where the installation requires it. The shield should be terminated at the amplifier and at the motor housing. The motor connector should be fully engaged and mechanically secured.
Feedback Planning
The feedback system provides rotor position and speed to the amplifier. The feedback type must match the amplifier configuration, and the wiring should be separated from the motor power cable. Incorrect feedback wiring can cause commutation faults or unstable motion.
During commissioning, the amplifier must be parameterized for the exact motor and feedback system. Direction of rotation, position limits, and following error thresholds should be set according to the machine design.
Commissioning Practice
Commissioning begins with a visual inspection and a supply check. The amplifier should be configured with the correct project data, and the safety functions must be validated before powered motion. Initial movement should be performed at reduced speed and without a high mechanical load.
The engineer should check direction, feedback polarity, brake behavior, and limit functions. After the basic tests, the axis should be operated at representative points, and the measured values should be recorded.
Diagnostics and Maintenance
Diagnostic messages should be interpreted together with the machine sequence. Supply problems, feedback faults, overtemperature, and parameter mismatch require different investigation paths. The cause should be identified before parts are exchanged.
Routine maintenance includes inspection of cabinet filters, cooling paths, terminals, and cable condition. Parameter backups should be kept current. Qualified personnel should perform service work, and power should be isolated before connections are touched. For exact technical data and approved application conditions, the product documentation for this amplifier should be used as the final reference.