In multiple pumps, the standard shaft drive of the F platform can carry Mmax=65 Nm (AZPF-1x)/85 Nm (AZPF-2x), and can be reinforced with shaft drive up to 160 Nm. The driving torque of each stage is verified by the formula ∑ (Δ pi × Vgi)/(18 π) ≤ Mmax, which may result in limited pressure at each stage.
Model selection code
The model code consists of 14 digits: AZP+F (series)+bearing version (1 standard/2 reinforced)+surface treatment (0 phosphating/1 phosphating strip pin/2 chrome strip pin)+displacement (004... 028)+steering (R/L)+drive shaft (C/S/H/N/R/P/F/Q/A)+front cover (B/O/C/M/L/P/N/T/A/G)+oil port (01/50/12/20/30)+sealing material (M=NBR/P=FKM/K=mixed)+rear cover (B no valve/D overflow/E/S flow valve/V combination valve)+valve setting value and special version code. Not all combinations are feasible and should be determined based on the preferred model list or in consultation with the manufacturer.
Operating characteristics and noise
The flow formula qv=Vg x n x η v/1000, torque M=Vg x Δ p/(20 x πx η hm), power P=qv x Δ p/(600 x η t). The characteristic curve was measured under the conditions of ν=32 mm ²/s and t=50 ℃. The noise level is measured in a low reflection measurement room according to DIN 45635 Part 26, with a distance of 1 meter and a speed range of 1000-4000 rpm. The sound pressure level is approximately 36-68 dB (A), which increases as the pressure increases from 10 bar to p2.
Key points of project planning
Most early failures of gear pumps are caused by oil contamination. It is recommended to maintain the filtration accuracy at ISO 4406 cleanliness level 20/18/15, and full flow filtration is recommended; Before injecting new oil, a filling device with a dedicated filter should be used. When used as an auxiliary steering pump, it is necessary to ensure that the steering system operates safely according to ECE R-79 even if the auxiliary pump fails. For details such as tightening torque, please refer to the "General Operating Instructions for External Gear Units" (07012-B).
Selection Tools and Conclusion
Users can use the AZ online configurator to quickly complete selection, directly obtaining order numbers, model codes, data sheets, dimension drawings, operating conditions, and tightening torques. They can also enjoy an additional 2% discount by ordering through the online store; The Fit4SILENCE Android app can quickly measure the noise level at the application site. With a wide pressure range, flexible shaft end and flange combination, integrated valve options, and multi pump capability, AZPF is the preferred solution in the design of high-pressure hydraulic power units.