Product Overview
The Bosch Rexroth AZPF series high-performance External Gear Pump High Performance AZPF belongs to the F-platform fixed displacement hydraulic pump, with specifications covering ten displacement levels (4, 5.5, 8, 11, 14, 16, 19, 22.5, 25, 28 cm ³) from NG4 to NG28. It is a core power component in the field of industrial hydraulics and mobile machinery. The maximum continuous working pressure of this pump can reach 250 bar, with a short-term intermittent pressure of 280 bar and a peak pressure of up to 300 bar. With large-scale industrial production, it ensures stable high quality and long service life.
AZPF adopts a slide bearing structure to withstand high loads, and the drive shaft can be supplied according to ISO or SAE standards, and supports customer customized solutions; The oil port form includes two types: connecting flange and threaded interface, and can achieve multi pump combination, providing high flexibility for the design of complex hydraulic systems.
Structural principle
The core structure of the AZPF external gear pump consists of a pair of gears supported in bearing bushings, and a housing with a front cover and a rear cover. The drive shaft extends from the front cover and is usually sealed by a shaft sealing ring. The bearing force is absorbed by sliding bearings, which are designed specifically for high-pressure conditions and have excellent dry running performance, especially at low speeds. The gear adopts a 12 tooth design, which can minimize flow pulsation and noise emissions.
The internal sealing of its high-pressure chamber relies on the compression force related to the working pressure to ensure optimal efficiency: the outer movable bearing liner is pressurized by the working pressure and compresses the gear as the sealing surface, and a special sealing element forms the boundary of the pressurized area; The radial seal between the gear tooth tip and the housing is formed by the minimum clearance related to pressure. The patented pressure compensation design of "axial compensation+radial micro gap" is the key to maintaining high volumetric efficiency of AZPF.
Key points of technical data
Taking the Series 2x series as an example, the continuous pressure of each specification from NG4 to NG16 is 250 bar, the intermittent pressure is 280 bar, and the peak pressure is 300 bar; NG19 continuous pressure 250 bar, intermittent 280 bar; NG22 continuous 220 bar, intermittent 250 bar; The continuous pressures of NG25/NG28 are 195/170 bar, respectively. The allowable range of absolute pressure at the suction port is 0.7... 3 bar. When configuring multiple pumps, the pressure difference on the suction side between each stage of the pump should not exceed 0.5 bar.
In terms of speed parameters, under the condition of oil with a flow rate of 12 mm ²/s, the minimum speed is 500-600 rpm when p<100 bar, and 1000-1400 rpm when p is between 180 bar and p2; The maximum speed is 2500-4000 rpm under P2 operating conditions (depending on specifications).
General technical data: unlimited installation location; The installation method is fixed with flanges or through-hole bolts with stoppers; The steering direction is divided into clockwise (R) and counterclockwise (L) according to the observation direction of the drive shaft, and the pump can only be driven in the indicated direction; Radial and axial forces on the shaft can only be applied after consultation. Environmental temperature range: NBR (nitrile rubber) seal -30 to+80 ℃, FKM (fluororubber) seal -20 to+110 ℃.
Hydraulic fluid and viscosity requirements
AZPF is designed for HLP mineral oil that complies with DIN 51524 1-3, and it is recommended to use HLP oil that complies with DIN 51524 Part 2 at least for high load conditions. Continuous operation allows viscosity to be between 12 and 800 mm ²/s, and the recommended optimal viscosity is between 20 and 100 mm ²/s. Cold start allows a maximum viscosity of ≤ 2000 mm ²/s. When selecting oil, it should be ensured that the viscosity falls within the optimal range within the working temperature range.

Integrated valve solution
To simplify the pipeline, flow control valves or relief valves can be integrated into the pump cover, including three-way flow control valves (residual flow return to the suction port, qconst=2 to 30 l/min), three-way flow valves with relief valves (p1=100 to 180 bar), flow valves that can be discharged and loaded, and relief valves that discharge pressure to the suction port (p1=5 to 250 bar). This type of solution is typically applied to hydraulic oil supply in power steering systems, which can output a constant flow rate regardless of the speed.
Drive and multi pump configuration
The driving methods include elastic couplings (couplings must not transmit radial/axial forces to the pump, and the maximum radial runout of the shaft to fitting groove is 0.2 mm), coupling sleeves (must be axially movable, lubricated with oil bath or oil mist, and the distance between the pump shaft and the driving shaft is 2+1 mm), tangential driving couplings, V-belt/gear transmission, and external bearing schemes. The maximum transferable driving torque is distinguished by shaft type: DIN 5482 B17 × 14 spline shaft 100 Nm, SAE J744 16-4 9T 110 Nm, 19-4 11T 180 Nm, cone shaft 1:5 155 Nm, 1:8 160 Nm, flat key shaft SAE J744 16-1 A 55 Nm, ISO ø 18 75 Nm.
In multiple pumps, the standard shaft drive of the F platform can carry Mmax=65 Nm (AZPF-1x)/85 Nm (AZPF-2x), and can be reinforced with shaft drive up to 160 Nm. The driving torque of each stage is verified by the formula ∑ (Δ pi × Vgi)/(18 π) ≤ Mmax, which may result in limited pressure at each stage.
Model selection code
The model code consists of 14 digits: AZP+F (series)+bearing version (1 standard/2 reinforced)+surface treatment (0 phosphating/1 phosphating strip pin/2 chrome strip pin)+displacement (004... 028)+steering (R/L)+drive shaft (C/S/H/N/R/P/F/Q/A)+front cover (B/O/C/M/L/P/N/T/A/G)+oil port (01/50/12/20/30)+sealing material (M=NBR/P=FKM/K=mixed)+rear cover (B no valve/D overflow/E/S flow valve/V combination valve)+valve setting value and special version code. Not all combinations are feasible and should be determined based on the preferred model list or in consultation with the manufacturer.
Operating characteristics and noise
The flow formula qv=Vg x n x η v/1000, torque M=Vg x Δ p/(20 x πx η hm), power P=qv x Δ p/(600 x η t). The characteristic curve was measured under the conditions of ν=32 mm ²/s and t=50 ℃. The noise level is measured in a low reflection measurement room according to DIN 45635 Part 26, with a distance of 1 meter and a speed range of 1000-4000 rpm. The sound pressure level is approximately 36-68 dB (A), which increases as the pressure increases from 10 bar to p2.
Key points of project planning
Most early failures of gear pumps are caused by oil contamination. It is recommended to maintain the filtration accuracy at ISO 4406 cleanliness level 20/18/15, and full flow filtration is recommended; Before injecting new oil, a filling device with a dedicated filter should be used. When used as an auxiliary steering pump, it is necessary to ensure that the steering system operates safely according to ECE R-79 even if the auxiliary pump fails. For details such as tightening torque, please refer to the "General Operating Instructions for External Gear Units" (07012-B).
Selection Tools and Conclusion
Users can use the AZ online configurator to quickly complete selection, directly obtaining order numbers, model codes, data sheets, dimension drawings, operating conditions, and tightening torques. They can also enjoy an additional 2% discount by ordering through the online store; The Fit4SILENCE Android app can quickly measure the noise level at the application site. With a wide pressure range, flexible shaft end and flange combination, integrated valve options, and multi pump capability, AZPF is the preferred solution in the design of high-pressure hydraulic power units.