System Overview: The three major variants cover from single machine to high-yield lines
Rexroth IndraMotion MTX is a customizable CNC control system launched by Bosch Rexroth, suitable for both single machine tools and complex high-capacity automated production systems. With a unified hardware and software platform, MTX can freely scale in terms of performance and functionality. The system currently offers three variants:
MTX compact: based on IndraControl L40 control module;
MTX standard: based on IndraControl P40 control module;
MTX performance: based on IndraControl P60 control module.
All control modules provide both CNC and PLC functions simultaneously. The highest configuration can achieve motion control for up to 64 axes and 12 independent CNC machining channels. The standard interfaces for the control module include: activating I/O through PROFIBUS-DP, connecting smart drives through SERCOS interface, connecting peripheral devices through Ethernet, and expanding more fieldbus through high-speed interface.
In terms of physical form, IndraControl L40 is designed as a terminal type and installed on the top cap guide rail of the control cabinet; P40 and P60 are PCI slot modules that can be inserted into idle slots on industrial PCs. Bosch Rexroth offers a variety of industrial PCs with different specifications and screen sizes. The operation panel, machine control panel, and PC keyboard are structurally compatible with each other, forming a comprehensive solution for machine control, operation, and visualization. The I/O side can be optionally equipped with an Inline module in the control cabinet or a Fieldline module installed on the nearest machine tool, which can be expanded into a scalable I/O system for PROFIBUS-DP and DeviceNet. The matching cable assembly enables the MTX system to quickly complete wiring.
Performance comparison of core control modules
P40/P60 (PCI slot module) is the main control unit for MTX standard and high-performance systems, with key performance data as follows:
Project IndraControl P40 IndraControl P60
Up to 8 axes and up to 64 axes
The maximum number of spindles is 2 and the maximum is 8
The maximum number of interpolation axes per channel is 4 and the maximum is 8
The maximum number of NC channels is 2 and the maximum is 12
SERCOS cycle minimum 6 ms minimum 250 µ s
The minimum block processing cycle is 6 ms and the minimum is 250 µ s
The technical specifications of the two are consistent: Celeron 650 MHz processor (265 kB L2 cache), 64 MB SDRAM, 1-8 MB SRAM, universal (5V/3.3V compatible) PCI bus, 5V DC ± 5% power supply (maximum 5A), typical power consumption of about 21 W.
L40 (Compact Terminal Type) is a space saving control module installed on the top cap guide rail of the control cabinet. With the help of onboard interfaces and 8 digital I/O, it can provide CNC performance and PLC functionality for up to 8 axes, 2 spindles, and 4 interpolation axes in an ultra compact terminal format. The processor is AMD LX800 500 MHz, 64 MB DRAM, and 128 kB NvRAM. By connecting special interface function modules in series through the integrated function module bus (FM bus), and adding Inline I/O modules to expand to 32 byte input/32 byte output (up to 63 Inline modules), personalized configuration can be achieved. L40 must be equipped with SRAM function module CFL01.1-Y1 (8 MB battery buffer storage, buffer time of 5 years, battery can be replaced without losing data) to operate.
Key points for L40 power supply and thermal design: According to DIN EN 61131-2, rated 24 V DC, tolerance -15%/+20%, residual ripple ± 5%, Umax 30 V、Umin 19.2 V; The three voltage lines ULS (logic), US (segment), and UM (main voltage) are fed into the PWR IN black plug-in terminal of the right power supply module (slot 5), with a maximum of 3 A for ULS and a maximum of 8 A for UM and US combined. The operating environment is+5 to+55 ℃, and when the load is high above 45 ℃, an optional fan CAL01.1-F1 must be installed; Fanless operation requires meeting the following requirements simultaneously: ambient temperature<45 ℃, 7.5 V Inline power load<1 A, onboard output load<1 A, and functional module load<10 W. Equipped with hysteresis fan control, it automatically switches to standby mode to prevent damage when the internal temperature reaches 75 ℃. The output enters a safe state and displays the "Temp!!!" alarm. The user program can trigger linkage by reading the internal temperature through the Lib function. IP54 protection level, altitude up to 2700 meters, vibration 1 g (57-150 Hz)/impact 15 g.
Matrix and Selection Logic of Industrial PC Platform
Standard industrial PC (normal industrial environment: operating vibration of 0.25 g, impact of 5 g, components continuously compatible for about 2 years):
VSP 16.1/40.1:12 "/15" color display integrated operation panel, 16 machine function keys, 6-slot PCI chassis, Celeron 2 GHz、512 MB RAM, Power supply 115-230 V AC or 24 V DC;
VSB 40+VDP 16/40 Passive Panel: The VSB 40 host is placed inside the control cabinet and connected to the VDP panel on the control console or cabinet wall through the GIGASTAR interface (12 "/15" display, VDP 40.2DFN with touch screen). The VSB and VDP connection cables are available in various lengths from 5 m to 30 m.
High end industrial PC (enhanced environmental capability: vibration 1 g, impact 15 g, components continuously compatible for at least 5 years):
VPP 16.1/40.1:12 "/15" color display, 3-slot chassis (2 x PCI+1 x PCI/ISA), Celeron M minimum 1.3 GHz, 512 MB or 1 GB RAM;
VPB 40+VDP Passive Panel: A high-end host with 3 or 4 slots installed inside the cabinet, connected to the VDP panel through the GIGASTAR interface, with a maximum cable length of 35 meters.
Key selection constraints: IndraControl P40 can only be used for Bosch Rexroth standard industrial PCs; P60 can be used for all Bosch Rexroth industrial PCs, including high-end models. The two modules are ordered as industrial PC sub items in the form of "Control Configuration (CFG -...)", and the configuration code includes both high-speed I/O interfaces (8 in/8 out) and DeviceNet extension options. The CFG code table should be accurately specified when ordering.

Peripheral and supporting components
VAM machine control panel (VAM 10/40/11/41): provides operation mode selection and manual operation, including LED buttons, feed and spindle magnification knobs, emergency stop button, and key switch; The back is equipped with a handwheel and manual operation panel interface, as well as 16 digital 24V inputs and 8 outputs, which communicate with the main control through PROFIBUS-DP (IKB0033 connects P40/P60 and VAM, IKB0034 is used for VAM cascading);
VCP Mini Control Panel (VCP 02/05/08/20/25): Compact operation and monitoring terminal, communicating via PROFIBUS interface; VCP 25 is a 5.7 "touch terminal, equipped with a 32-bit RISC CPU (74 MHz), 3 MB flash, and 512 kB CMOS-RAM;
VAK PC keyboard: Pull out (VAK 10.1/40.1, 86 key PS/2 with integrated pointing device) and embedded touchpad keyboard (VAK 11/41106 key low installation depth);
UPS uninterruptible power supply (VAU01.1S-230-255-NN): triggers the operating system to shut down in an orderly manner when there is a brief voltage drop or a prolonged power outage. It is recommended to always install it to avoid data loss and communicate with the industrial PC via serial port COM1;
External battery pack (SUP-E01-BTV16/40): provides power-off data protection for high-end industrial PCs, connected via IKL0264 cable (1 m/3 m);
RECOM Inline module: Modular I/O (bus coupling, feeding, 24V input/output, relay, analog, counter, etc.) installed on the top cap guide rail inside the cabinet;
RECOM Fieldline module: IP65/IP67 protection, used for direct access of sensors/actuators in harsh environments near the station, with three models covering 8-in, 4-in/4-out (2A), and 8-out (2A).
Interface and Diagnostic Key Points
P40/P60 provides three sets of dual LEDs (red green multiplexing) and one red LED on the keyboard:
Ready Active/Watchdog Error LED: Green light=Ready contact closed, watchdog triggered; Red high-frequency flashing=local CPU is in reset state; Red light constantly on=Ready error has occurred and the watchdog is responding;
Power Good/Trigger LED: Off=At least one voltage of the four onboard DC/DC transformers is incorrect (due to vector group or PC power failure); Green=normal voltage on all four channels;
SERCOS LERR LED: Directly driven by the SERCON816 controller, it reflects the quality of fiber optic reception and should not light up under normal conditions;
Watchdog Reset button: Reset pending watchdog errors, cancel PC NMI disable signal, or switch to RAM Boot during power on and LRRESET periods.
The SERCOS interface X7S1/X7S2 uses fiber optic to construct an IEC 1491 ring topology, with the ring starting and ending at the control module (X7S2 output → first driver input →... → last driver output → X7S1 input), with a maximum transmission rate of 16 Mbaud. The PROFIBUS-DP main station interface X7P has a maximum of 12 Mbaud and connects the VAM operation panel to the Inline/Fieldline sensing execution layer. Ethernet (RJ45) can connect to the upper computer layer with a maximum of 100 Mbaud. Ready contact (maximum 60 V/1 A) disconnects when the module is not started or the watchdog error occurs. It is recommended to connect it to the machine emergency stop link; The signal line must use shielded cables and large-area shielded connectors, as poor shielding may cause misoperation.
The maintenance strategy for P40/P60 is to replace the entire module, and on-site maintenance is prohibited. Only the CPU fan (Celeron P3 fan, part number 1070922532) can be replaced separately; Complete module spare parts: P40 corresponds to CMP40.1-SP-304-FN-NNNN-NW (R911170066), P60 corresponds to CMP60.1-SP-304-FN-NNNN-NW(R911307078)。 When replacing fans or modules, it is necessary to comply with the requirements of EN 61340-5-1/-5-2 for electrostatic discharge protection.
Core clauses of safety regulations
The system follows the ANSI Z 535 hazard level classification (Danger=inevitable death or serious injury; Warning=Possible occurrence; Caution=mild to moderate injury or property damage), and provide multiple mandatory regulations for electric drive:
>50 V electric shock protection: The grounding conductor must be permanently connected and non removable. When the leakage current is greater than 3.5 mA, the minimum cross-sectional area of the grounding copper wire is 10 mm ²; After the power failure of the driving and filtering components, wait for 30 minutes for the capacitor to discharge. Before operation, measure the capacitor voltage to confirm safety; Residual current protectors (RCDs) cannot be used for electric drive, and alternative methods such as overcurrent protection devices must be used for indirect contact protection;
Dangerous motion protection: Parameter errors, sensor/encoder failures, software firmware defects, etc. may all cause dangerous movements immediately after the device is powered on or after a long period of trouble free operation; Safety fences, shields, and light curtains must be able to withstand maximum momentum; After a power outage on the vertical axis, mechanical locking, installation of external braking/clamping mechanisms, or sufficient balancing are required - standard motor holding brakes or external holding brakes directly controlled by the drive controller are not sufficient to ensure personal safety;
Electromagnetic field health protection: wearers of pacemakers, metal implants, and hearing aids are not allowed to enter electrical equipment operation areas or storage, maintenance, and assembly areas containing permanent magnet motor components;
High temperature protection: After the motor surface runs or stops, the temperature can exceed 60 ° C/140 ° F, and the cooling time is about 140 minutes (about 5 times the thermal time constant); After the drive controller and reactor are powered off, wait for 15 minutes;
Battery and pressure system: Heating/charging/putting into fire/dismantling batteries are prohibited. Used batteries are hazardous materials and must be disposed of separately in accordance with local regulations; Before disassembling and assembling the pressure pipeline, it is necessary to release pressure and drain it.
Data backup system: Acronis True Image solution
MTX/MLC/IL and other PC control and HMI systems (starting from Windows XP SP2) have built-in Acronis True Image backup tools, installed and archived in the C: partition. The backup object is the partition/hard disk image of the operating system and all user programs (rather than selective backup of user data, which is provided by IndraWorks mechanism). The backup medium can be a network backup server or a USB hard drive, and a full disk backup requires at least 3 GB of space per unit; The network requires 10/100 Mbit, TCP/IP protocol, and DHCP server.
Key mechanisms and operational points:
Acronis Secure Zone: A protected logical partition on a hard drive that is inaccessible to regular Windows applications (FAT32, within an extended partition, without a drive letter), used for fast local recovery - even if the local partition is damaged and cannot boot, the image can still be restored from this zone when the hard drive is still intact. It is strongly recommended to place the storage space in a data partition (usually D: ) instead of an operating system partition during creation, with a recommended size of 10 GB (consistent with factory settings);
Startup Recovery Manager: Press the F11 key to launch Acronis True Image's mini OS boot manager before the operating system starts, and repair damaged system partitions without the need for rescue media. Activated at the factory, but may need to be reactivated after replacing the hard drive and restoring the image;
Incremental backup: Only save sectors that have changed since the last full image, saving time and space; A full backup must exist first, and incremental files are only suitable for hard drives or network drives (in the case of removable media, the original full backup will become invalid if separated from the media). Warning: If the "overwrite image archive with full image" option is activated, the archive will be completely rebuilt and all existing incremental backups will be lost;
After creating the image, a "Check Image" verification must be performed - data integrity is the most important attribute of image archiving. If the verification fails, the data carrier should be replaced and recreated;
Recovery operation: It is recommended to restore only through Startup Recovery Manager or rescue media (Windows system partitions can only be restored through these two methods); Priority is given to restoring only one partition, and the partition size can be adapted to the new hard drive. When the target hard drive is smaller than the source drive, all partitions (including Secure Zones) are automatically compressed and cannot be manually adjusted; Maintain the original size when equivalent or larger;
Image mounting browsing: Explore Image can assign temporary drive letters to partition images, retrieve copied files using Windows Explorer, and then use Unplug Image to cancel the drive letter assignment;
Rescue medium: created on a CD (Full version with a large number of drivers is recommended) or 7 1.44 MB floppy disk packs, used for boot recovery after irreparable hard drives or newly installed hard drives;
Planned task: Scheduled backup jobs can only be created in the Windows main window (daily/workday/every X days/week/month), and should be scheduled to be executed during non production operating hours of the control system.