ABB EL3020 Model EasyLine Continuous Gas Analyzers

来源: | 作者:FAN | 发布时间 :2025-07-09 | 533 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

ABB EL3020 Model  EasyLine Continuous Gas Analyzers

Equipment Overview

Core function: EL3020 is a multi-component continuous gas analyzer that can simultaneously measure up to 5 gas components, suitable for various process and emission monitoring scenarios, and supports flammable gas measurement.

Core features: Equipped with automatic calibration function (including pump and valve control), it can simplify calibration through air or built-in calibration units, without the need to test gas cylinders; Provide customizable analog outputs, digital inputs/outputs, and Modbus interfaces; Adopting a modular design, it is easy to maintain and has self-monitoring function, which can prompt maintenance needs.

Shell design: 19 inch rack mounted shell (3 height units) with a protection level of IP20.

Measurement technology (analyzer)

Uras26 infrared photometer

Measurement object: Infrared active gas components such as CO, NO, SO ₂, etc.

Measurement range: adjustable between 0-500ppm (NO 750ppm), 0-1000ppm, 0-3000ppm, and 0-1Vol. -% to 0-100Vol. -%, with a maximum range ratio of 1:5. Specific ranges can be set according to factory requirements, but the range should not be set within the ignition limit.

Performance indicators: Linear deviation ≤ 1% range; Repeatability ≤ 0.5% range; Zero drift ≤ 1% range/week; Sensitivity drift ≤ 1% measured value/week; Output fluctuation (2 σ) ≤ 0.2% range; Detection limit (4 σ) ≤ 0.4% range.

Influencing factors: Flow rate within the range of 20-100l/h affects within the detection limit; The impact of environmental temperature changes on zero point is ≤ 2% of the range/10 ° C, and on sensitivity (without a thermostat) is ≤ 3% of the measured value/10 ° C. If a thermostat is installed (55 ° C), the impact is ≤ 2% of the measured value/10 ° C. After calibration by a pressure sensor, the impact of pressure changes on sensitivity is ≤ 0.2% of the measured value/1% of the pressure change.


Magnos206 Oxygen Analyzer

Measurement object: O ₂ in process gas or nitrogen.

Measurement range: minimum range of 0-2Vol. -% O ₂, maximum range of 0-100Vol. -% O ₂, can be set to suppress zero point range (such as 98-100Vol. -% O ₂).

Performance indicators: Linear deviation ≤ 0.5% range; Repeatability ≤ 1% range; Zero drift ≤ 0.1Vol. -% O ₂/week; Sensitivity drift ≤ 0.1Vol. -% O ₂/week or ≤ 1% measured value/week (whichever is smaller); Output fluctuation (2 σ) ≤ 0.5% minimum range; Detection limit (4 σ) ≤ 1% minimum range.

Influencing factors: Flow rate within the range of 30-90l/h affects ≤ 0.1Vol. -% O ₂; Multiple associated gases have different effects on zero point; The impact of ambient temperature on zero point is ≤ 1% range/10 ° C (≤ 2% range/10 ° C when combined with Uras26), and the impact on sensitivity is ≤ 0.2% measured value/10 ° C. After correction, the impact of pressure changes is ≤ 0.01% measured value/1% pressure change or ≤ 0.002Vol. -% O ₂/1% pressure change (whichever is greater).


Caldos27 Thermal Conductivity Analyzer

Measurement object: Binary gas mixtures with different thermal conductivities, such as Ar in O ₂, H ₂ in Ar, CH ₄ in N ₂, etc.

Measurement range: There are different minimum ranges and ranges with zero suppression for different gas combinations, with a maximum range of 0-100Vol. -% or 0Vol. -% to saturation. The range can be freely adjusted within a given range, but should not be set within the ignition limit.

Performance indicators: Linear deviation ≤ 2% range; Repeatability ≤ 1% range; Zero drift ≤ 2%, minimum possible range/week; Sensitivity drift ≤ 0.5% minimum possible range/week; Output fluctuation (2 σ) ≤ 0.5% minimum range; Detection limit (4 σ) ≤ 1% minimum range.

Influencing factors: When the flow rate changes by 10l/h, it affects the range by ≤ 0.5%; The impact of environmental temperature changes is ≤ 1% range/10 ° C; the impact of air pressure changes on the minimum range is ≤ 0.25% range/10hPa, and the larger the range, the smaller the impact.

Electrochemical oxygen sensor

Measurement object: O ₂, and can only be used in combination with Uras26 infrared photometer.

Measurement range: adjustable from 0-5Vol. -% O ₂ to 0-25Vol. -% O ₂, with a minimum range of 0-5Vol. -% O ₂.

Performance indicators: Linear within the range of>1Vol. -% O ₂; Repeatability ≤ 0.5% range; Zero point long-term stability; Sensitivity drift ≤ 1% measurement range/week; Output fluctuation (2 σ) ≤ 0.2% measurement range; Detection limit (4 σ) ≤ 0.4% measurement range.

Influencing factors: Flow rate within the range of 20-100l/h affects ≤ 2% of the measurement range; The impact of changes in ambient temperature within the range of 5-40 ° C is ≤ 0.2Vol. -% O ₂/10 ° C; the impact of changes in air pressure without pressure correction is ≤ 1% of the measured value/1% of the air pressure change, and ≤ 0.2% of the measured value/1% of the air pressure change with correction (to be connected to Uras26 with pressure sensor).


Integrated gas feed (optional)

Version: A module that includes a microfilter and a flow sensor; Another type includes a microfilter, solenoid valve, pump, coarse filter, capillary tube, and flow sensor module.

  • ABB FAU810 C87-11006 / C10-12010 Flame Analyzer
  • Pilz PSSu E F 4DI Safety Input Module
  • Pepperl+Fuchs KFD2-UFC-1.D Frequency Converter
  • Pacific Scientific VDE0530-S1 Stepper Motor
  • Pacific Scientific 6410-001-N-N-N Stepper Drive
  • PACIFIC LA23GCKC-1Y Servo Motor Reliable Automation Motion Solution
  • PACIFIC LA23GCKX-P500A Servo Motor Advanced Industrial Motion Control
  • PACIFIC LA23GCKC-P500A High Precision Servo Motor for Industrial Automation
  • Pacific Scientific E32NCHA-LNN-NS-00 Hybrid Stepper Motor
  • Pacific Scientific SCE903A3-002-01 Servo Drive
  • Pacific Scientific 6410-024-N-N-N Stepper Motor Drive
  • PALCLEAN JD-BXG Industrial Control Module
  • Panametrics 704-673-20 Ultrasonic Flow Meter
  • Panasonic MSD043A1XX AC Servo Driver
  • Panasonic KX-FT936CN Plain Paper Fax Machine
  • Panasonic DL-1109CWS Electric Bidet Toilet Seat
  • PACIFIC SCIENTIFIC 33VM52-000-29 LDA-196-1000CE Servo Motor Controller
  • PACIFIC LA23GCKC-1G Linear Actuator Specifications
  • PACIFIC PC3406AI-001-E Stepper Controller Manual
  • PACIFIC SCE904AN-002-01 Servo Drive Analysis
  • PACIFIC 6445-001-K-N Digital Servo Drive Details
  • PACIFIC SCIENTIFIC R43HCNA-R2-NS-VS-00 Motor Data
  • Pacific Scientific H32NCHA-LNN-NS-00 Hybrid Motor Performance
  • ABB DSAI130DK01 3BSE020828R1 Analog Input Module
  • Parker 466966-0001-3820 Industrial Component Data
  • PARKER ZETA6104 Microstepping System
  • PARKER COMPAX 2500S/F3 Servo Drive Manual Details
  • PARKER CX-DH Indexer Drive Technical Specifications
  • PARKER 6K8 Motion Controller Features and Specifications
  • PARKER EVM32-BASE I/O Module Base Technical Specification
  • ABB Pb PN-112718 Digital Input Module
  • Pb PN-45734 PN-73899 Industrial Automation Module
  • Control Techniques Pb PN-40856 Industrial Control Module
  • Pb PN-104412 4002910956 Industrial Control Module
  • Siemens Pb PN-41513 Industrial Ethernet Module
  • Pelco PA30-0065-00-A1 PTZ Decoder Module
  • Pentek FILTER 3F11 800000919 Pleated Filter Cartridge
  • Pepperl+Fuchs RSD-TI-EX8 Temperature Input Module
  • PERITEK AC7-00712-1113 Industrial Interface Module
  • PFEIFFER EVR116 Vacuum Control Module
  • Pepperl+Fuchs RSD-CI-EX8 Hazardous Area Interface Module
  • PEPPERL+FUCHS 2108HAT Intrinsic Safety Barrier Module
  • Philips 958481320201 PROC+ Processing Unit
  • Philips 958481321300 PSB Power Supply Board
  • Philips 958481321220 PD208 Power Module
  • PHILIPS 958481321200 PD216 Control Module
  • PHILIPS 958481320201 PROC PLUS Control Module
  • Philips 958481320400 PIF Interface Module
  • Philips 958481320100 LCB Control Board
  • PHILIPS 958481223220 Industrial Control Module
  • PHILIPS 958481223223 Industrial Control Module
  • PHILIPS 958481321300 Industrial Control Module
  • PHILIPS SCM040 Digital Output Synchronization Module
  • PHILIPS DSI020 Data Storage Interface Module
  • PHILIPS OPM010 Optoelectronic Control Module
  • PHILIPS VBM010 Industrial Automation Module
  • PHILIPS VBM030 Turbine Supervisory Instrumentation
  • PHILIPS PR1613 Industrial Control Module
  • PHOENIX PATG1/23 1013847 Ground Terminal Block
  • Phoenix Contact IB ST 24 AI 4/SF Analog Input
  • Phoenix Contact OPC5315-004-AB Industrial PC
  • Phoenix Contact UMK-SE11.25-1 Side Element
  • PHOENIX 2961192 Relay Module
  • PHOENIX IB ST ZF 24 AI 4/SF Analog Input Module
  • Phoenix Contact PLC-BSC-24DC/21 Relay Base
  • Phoenix Contact UK6N Feed-Through Terminal Block
  • Phoenix Contact UK4-T Disconnect Terminal Block
  • Phoenix UK3N Screw Terminal Block
  • Phoenix QUINT-PS-100-240AC/10 Power Supply
  • Phoenix QUINT PS-100-240AC/24DC/10 Power Supply
  • Phoenix UT 6-HE SI Surge Protection Terminal Block
  • Phoenix UT 4-MTD Feed-through Terminal Block
  • Phoenix UT 4-HE SI Surge Protection Terminal Block
  • Phoenix IBS 24BK-I/O-T Bus Coupler
  • Phoenix Contact HDFK4 High-Current Terminal Block
  • PHOENIX ST-SI-UK4 Fuse Terminal Block
  • PHOENIX FLMC10BASE-T/FO G850 Fiber Media Converter
  • PHOENIX CONTACT QUINT-PS-100-240AC/24DC/40 Power Supply
  • PHOENIX CONTACT QUINT-DIODE/40 Redundancy Module
  • Phoenix Contact 2884208 Wireless I/O MUX
  • Photonetics 3646 HE 1540 Tunable Laser Source
  • PI C-663.12 Mercury Multi-Axis Step Motor Controller
  • PI C-663.10 Mercury Step Motor Controller
  • Pillar CB6687-2L Industrial Communication Board
  • Pilz DE-106712 A.F.051.5/01 Safety Module
  • Pilz 680003 Safety Relay Module Set
  • Pilz 301140 PNOZ X3 Safety Relay
  • Pilz P1U-1NB Safety Relay
  • Pioneer PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3326B-6-1-2-E Power Supply
  • Pioneer Magnetics HYRSP-1500-56 Power Supply
  • Pioneer Magnetics PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3328BP-6 Power Supply
  • Potter & Brumfield SDAS-01-7Y2S1024 Relay
  • Powec PMP10.48 SIC High-Efficiency Rectifier
  • Powerbox PU200-31C Industrial DC-DC Converter
  • PIONEER MAGNETICS PM3398BP-6-1-3-E Power Supply Module
  • PIONEER MAGNETICS PM1253AL-6-3-Z03 Power Supply Module
  • Powerex PD411811 Rectifier Diode Module
  • Power-One MAP55-1024 AC-DC Power Supply
  • ProSoft MVI56-MDA4 ControlLogix Multi-Protocol
  • POLYSPED PRD2-200 Industrial Drive Module
  • P-OPEN P-OPEN-P4-150 PAC-OP150 Operator Panel
  • ABB Processor 958481321210 350211080320 Rugged CPU
  • ABB Processor 958481320201 350211080460 Safety CPU
  • ABB Processor 958481321200 350211080320 CPU Module
  • ABB Processor 958481321220 350211080320 CPU Module
  • ABB Processor 958481320100 350211080090 CPU Module
  • Pro-Face PL5901-T42-24V HMI Touch Panel
  • PROFIBUS PB3-VME-1-E V1.2.2 Interface Card
  • PROMESS 850040060P Force Displacement Monitor
  • PROSOFT AN-X2-AB-DHRIO DH+ and Remote I/O Gateway
  • PROSOFT RLX2-IFH24E Industrial Wireless Radio Module
  • PROSOFT 5202-DFNT-MCM4 DF1 to EtherNet/IP Gateway
  • PROSOFT PLX35-NB2 EtherNet/IP to Modbus TCP Gateway
  • ProSoft 5201-MNET-MCM-WEB Modbus TCP/Serial Gateway
  • ProSoft 5304-MBP-PDPMV1 Modbus Plus to PROFIBUS DP Master
  • ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave
  • ProSoft 5301-MBP-DH485 Modbus Plus to DH485 Gateway
  • ProSoft 6104-WA-PDPM Wireless PROFIBUS DP Master
  • ProSoft MVI56-LTQ ControlLogix Limitorque Master
  • Prosoft 5304-MBP-PDPM PROFIBUS Master Module
  • Prosoft 1452-25M Relay Output Module
  • Prosoft MVI56-MNETR Modbus TCP/IP Module
  • Prosoft MVI69L-MBS Modbus Serial Module
  • Prosoft PLX32-EIP-SIE Ethernet Gateway
  • Prosoft MVI56-PDPS PROFIBUS DP Slave Module
  • Prosoft PMF1327205 Gateway Module