Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

FANUC 16i/18i/21i hardware connection and troubleshooting

F: | Au:FAN | DA:2026-05-06 | 1018 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

FANUC Series 16i/18i/21i MODEL B CNC Hardware Connection and On site Maintenance Guide

In the field of CNC machine tools, FANUC's Series 16i, 18i, 21i MODEL B (as well as enhanced models with the suffix "i") are still in service in a large number of devices due to their stable performance and powerful functionality. For on-site maintenance engineers, facing a FANUC CNC system that has been running for many years, every link from power supply connection, I/O wiring, servo and spindle connection, to emergency stop circuit design and battery replacement can become the source of faults. This article is based on the hardware connection manual of the CNC series, combined with on-site practical experience, to provide a complete technical guide from installation specifications to troubleshooting.

Installation and environment: Building a solid foundation for reliable operation

The FANUC CNC control unit is an open device and must be installed in a closed control cabinet with a protection level of not less than IP54. Strictly follow the following requirements during installation to avoid early failures caused by poor heat dissipation or interference.

1.1 Cabinet heat dissipation and spatial spacing

Control unit heat dissipation: The control unit is equipped with a built-in fan, allowing air to enter from the bottom and exit from the top. Therefore, a ventilation gap of at least 100mm must be reserved above and below the unit (this gap is still recommended for units with fans). It is strictly prohibited to install the control unit horizontally or upside down.

I/O module spacing: Connector Panel I/O modules also require a gap of 100mm above and below for wiring and ventilation. Devices with high heat generation, such as power supplies and transformers, should not be installed under the I/O module.

Cabinet surface: For small operator's panels, their heat dissipation capacity is approximately 8W/m ² ·℃ for coated metal surfaces and 3.7W/m ² ·℃ for plastic surfaces. If the total internal heat generation exceeds the cooling capacity of the cabinet, a heat exchanger or fan must be installed.

1.2 Anti noise measures: grouped wiring, shielding, and grounding

The signal lines of the CNC system are divided into three groups according to anti-interference requirements:

Group A: Main power line (AC 220V), secondary power line, servo motor power line, AC/DC relay/solenoid valve coil line. These cables must be separated from groups B and C by at least 100mm or use electromagnetic shielding.

Group B: DC 24V solenoid valve/relay wire, DI/DO wire from CNC to high-voltage cabinet. Try to stay away from Group A as much as possible and it is recommended to add shielding.

Group C: I/O Link cables, position/speed feedback cables, handwheel wires, RS-232C communication wires, battery wires, etc. between CNC and I/O units. Shielding treatment must be carried out.

Grounding points:

The protective grounding (PE) resistance should be ≤ 100 Ω (Class D grounding), and the cross-sectional area of the grounding wire should not be less than that of the power line.

The SG (signal ground) terminal of the CNC control unit must be connected to the grounding copper bar inside the cabinet with the shortest wire (recommended<30cm).

The shielded cables of servo amplifiers and spindle amplifiers must make extensive contact with the grounding plate through cable clamps, rather than being single ended grounded through thin wires. The grounding plate material should be nickel plated steel plate (thickness ≥ 2mm).

1.3 Noise Suppressor and Lightning Protection

For AC/DC relays and solenoid valves, CR spark suppressors (capacitors+resistors in series) must be installed at both ends of the coil. The resistance value is taken as the DC resistance of the coil, and the capacitance value is approximately I ²/10~I ²/20 μ F (I is the steady-state current). Varistor cannot be used alone as it cannot suppress voltage spikes.

To prevent lightning strikes, it is recommended to install surge absorbing components (such as Okaya's R · A · V-781B) between input power lines and between lines and ground. The total length of the connection between the absorbing component and the protected equipment during installation should be ≤ 2m.

Power System and Battery: Power on Timing and Data Preservation

2.1 Specification of 24V DC power supply

The CNC control unit, peripheral I/O modules, LCD units, etc. all require stable 24V DC input. The external power supply must meet the following requirements:

Output voltage:+24V ± 10% (including ripple and noise, 21.6V to 26.4V)

Instantaneous power outage holding time: ≥ 10ms (100% load drops to 0) or ≥ 20ms (50% load)

For machine tools with vertical axes, it is recommended to use a power supply with a longer holding time to reduce the distance of the vertical axis falling during power failure.

Not recommended power circuit:

The use of simple rectification filtering (only diode+capacitor) cannot maintain the output voltage during instantaneous power failure.

Connecting the CNC to a high-power load that frequently starts and stops (such as a large contactor) on the same 24V output line can cause the voltage to drop instantly below 21.6V.

  • LTI DRIVES CDE34.010 D2.4 Servo Drive Unit
  • LUST LTi Drives CDD34.005.C2.1 Servo Drive
  • LTi Drives SO84.012.0002.0100.2 Servo Controller
  • LUST LTi Drives CDE34.010.D2.4 Servo Drive
  • LUST LTI Drives CDF30.008 Servo Drive
  • LTi Drives SO CM-P.0010.11.00.0 Power Module
  • LTi DRiVES SO84.008.0002.0100.2 Servo Controller
  • LTI MOTION Servo Drive SO22.006.0040.1000.1
  • LTi DRiVES SO24.007.0030.1000.0 ServoOne Junior
  • LTi DRiVES LUST BC1300 Braking Module
  • LUST LTI DRIVES CDE34.010 Variable Frequency Drive
  • LUST LTI DRIVES CDA32.004 Servo Drive
  • LTi DRiVES LST-074-2-30-560/T1 Servo Motor
  • LUST LTI DRIVES CDB32.008 Servo Drive Module
  • Lust Antriebstechnik LTI Drives VF1204S Inverter
  • Lust LTI Drives CDE32.008 C3.0 Positioning Controller
  • LTI Drives LUST Servo One C-5633 D-35633
  • Lust LTI Drives CDA34.008.C1.3 Servo Controller 3kW
  • LTI CDF30.008 C2.6 Servo Drive 10962161
  • LUST LTi Drives CDB32.004 C2.3 SH Servo Drive
  • Lust LTi Drives CDE34.010 D2.0 Servo Drive
  • LTi Motion CDA32.006 Servo Drive with CM-CAN1
  • Lust LTI Drives CDB32.008 C2.3 Servo Controller
  • LTi CDE34.017.W3.0 Servo Drive
  • LUST LTI LST-074-2-30-320/T1 Servomotor
  • Lust LTi CDF30.002 C3.0 Positioning Controller
  • LTi DRIVES CDF30.008.C2.4 Drive
  • LUST LTI CDB32.008 W2.4 BR PC1 Drive
  • LTi SO84.004.0002.0100.2 Servo Controller
  • LTi SO84.012.0030.0011.2 ServoOne Drive
  • LTI Drives LUST Servo One C-5633 D-35633
  • LTi DRiVES c-line Smart Card A028.V01.1
  • LUST LTI CD A34.008 W1.4 BR Drive
  • LUST LTI LSH-097-2-30-560/T1 Servomotor
  • LUST LTI LST-074-2-30-320/T1 Servomotor
  • LUST LTi CDB32.004 C2.4.SH Servo Drive
  • LTI Drives PM-E40.2DRA054P Pitch Inverter
  • Lust LTI Drives CDF30.008 Servo Drive 8673548
  • LTI Drives CDF30.002.C0.7 Servo Controller
  • Lust LTI Drives CDB32.008.W2.4 Servo Drive
  • Lust LTI Drives CDB34.003 Servo Motor Driver
  • Lust LTI Drives CDA32.004 Servo Drive 3084456
  • Lust LTI Drives CDE34.005.W2.2 Servo Drive
  • Lust LTI Drives CDA34.006.W3.0 Servo Drive
  • LTI Drives CDF30.008.C2.4 Servo Controller
  • LTI Drives Lust CDB32.004.C2.4.SH Servo Drive
  • Delta Design 1666339-501 Micro Stepper PCB 114970
  • APEXEL 100X Microscope Mobile LED Pocket Lens
  • Micro Innovation XV-152-D4-10TVR-10 Touch Screen
  • Micro Innovation XVH330-57MPI-1-10 Touch Screen Glass
  • Delta Design 1666339-501 Micro Stepper PCB 114967
  • Micro Design MC100-MA V3 Board
  • Delta Design 1666339-501 Micro Stepper PCB 114968
  • Delta Design 1666339 PCB Micro Stepper ITR 116487
  • Micro Innovation XV-440-10TVB-1-10 Panel
  • Sterling 9B21-3 Micro Switch Durable Design
  • ATTINY104-XNANO Microchip AVR Prototype Board
  • Delta Design 1666339 Micro Stepper PCB ITR 116539
  • Super Micro X7SBJ Industrial Main Board
  • Delta Design NMS BD 1698437-501 Stepper Board
  • Micro Innovations Turbo Track Keyboard KB420BL
  • Micro Design PC-1 PC-1-H-DU010 Operator Panel
  • TCI MICRO MD 250mA 7W Dimmable LED Driver
  • Delta Design 1666339 Micro Stepper PCB ITR 116485
  • Delta Design NMS BD 1698437-501 Stepper Board
  • Life Instruments 714-1120-1U Micro Curette
  • Delta Design 1657925-501 Micro Processor PCB
  • Micro 100 RTC-125-2 Carbide Engraving Tool
  • Micro Design Inc. 2106022 Liquid Level Sensor PCB
  • Periodontal Micro Surgical Full Kit 20pc Blue Titanium K1004
  • Micro Innovation XN-2DO-24VDC-0.5A Module
  • Wide Innovative Technology PS-01 Micro Positioner Set
  • HU FRIEDY NH5020 Castroviejo Needle Holder Set
  • Moeller Micro Innovation XV-232-57BAS-1-10 Touch Screen
  • Micro Design System MCVP-300VR Control Module 24VDC
  • Scanlan 3003-234-1 Titanium Jacobson Needle Holder
  • Micro Innovation XV-102-B0-35TQR-10-PLC Panel
  • Promot Micro Design 3x8 Output 2187F
  • Micro Innovation LIC-SW-Galileo 91 30 000600 License Certificate
  • Micro Design AI0486.A4-50 Control Module Board
  • Micro Innovation XN-2DO-24VDC-0.5A Output Module
  • Micro Design Not-Aus Relais AE 8.96 AE 896
  • Micro Innovation CPC-600M-10 Ferag Touch Panel HMI
  • Micro Design System 96-002-09/1 Adapter 18 Bit
  • Micro Design LK3160 AI0486 Motherboard
  • Micro Design System 96-002-01/2 GF-1 CPU Board
  • Micro Design Systems CF1-10TVA-100 Micro Panel
  • Eaton Micro Innovation XP-702-C0-15TXI-10 Panel
  • HU FRIEDY Castroviejo NH5020 Needle Holder
  • MPM Micro Precision 3.BMT100 P02 Balancing Station
  • Micro Innovation GF1-10TVD-101 Touch Panel
  • Micro Innovation XV-102-B0-35TQR-10-PLC
  • Micro Innovation XP-601-15T-10 Touch Panel
  • Micro Innovation License Certificate 9130000650 LIC-SW-MXPRO
  • Micro Innovation XVC-601-GTI-15-V1-000 Panel
  • MI Micro Innovation HPT-100-82FGBA-01 Panel
  • Micro Innovation XV-102-B3-35TQR-10 Panel Cable
  • Micro Innovation MC2-440-10TVB-1-2 HMI Panel
  • Promot Micro Design 2x8 Output 2087F
  • Micro Innovation XN-16DO-24VDC-0.5A Output Module
  • Micro Design System 96-002-03/1 Power Supply Board
  • Touch Screen for Moeller XV-252-57CNN-1-10 Digitizer
  • Micro Design Systems 96-002-03/1 Power Supply Board
  • Micropipette Variable Range 100-1000 Microliter
  • Murphy Nerve Hook 9 Inch Neurosurgery Instrument
  • Micro Innovation XN-2DI-24VDC-P Input Module 225169
  • Micro Innovation ST-GF0-57E0D-000 Touch Panel
  • Micro Innovation XN-S4T-SBBC Base Module
  • Micro Innovation XN-2DO-24VDC-0.5A-P Output
  • Micro Innovation XN-PF-24VDC-D 8550225186
  • Eaton Micro Innovation XV-230-57MPN-1-10 Panel
  • Micro Design MC100-BED REV2 ME96049 Board
  • Micro Innovation XN-PF-24VDC-D 85 50 225186
  • Micro Innovation XN-PF-24VDC-D Communication Module
  • Micro Innovation CPC-600M-10 FERAG Panel
  • Micro Design Systems 96-002-05/1 P-Bus Adapter
  • Micro Design System MPB1-TP 97-003-01/4 PCB Card
  • Eaton Micro Innovation XVS-440-12MPI-1-10 HMI
  • Micro Components 900806 Test Circuit Board
  • Promot Micro Design PL59-MOC ME95035
  • Micro Innovation XV-440-10TVB-1-21 Panel
  • Micro Forceps 3003-934 Micro Surgical Instrument
  • Eaton Micro Innovation XN-32DI-24VDC-P Module
  • MICRO INNOVATION AG XN-32DI-24VDC-P Input Module
  • Micro Innovation XN-PLC-CANOPEN 85 50 274124 Controller VN01-01
  • Micro Innovation XN-S4S-SBBS Base Module
  • Micro Innovation XN-2DO-24VDC-0.5A-P Module
  • Micro Design MPB2-TP Module