Foxboro-IAP10-IA-Differential-Pressure-Transmitter
DESCRIPTION
The Foxboro® brand Models IAP10, IGP10, IAP20, IGP20, and IDP10 are low power, voltage output transmitters that provide precise, reliable measurement of gauge, absolute, and differential pressure, draw no more than 3 mA, and transmit a 1 to 5 V dc output signal.
LOW POWER DESIGN
When you need a low power, low voltage transmitter, these I/A Series Pressure Transmitters deliver:
1 to 5 V dc Output Signal
9 V dc Minimum Voltage
3 mA Maximum Current
EXTENSIVE LINE
Unsurpassed breadth of line for measurement types, materials, and process connections. Can also be provided with direct connect or capillary connected pressure seals, and industry specific seals for sanitary, and pulp and paper processes. The line also includes a selection of traditional or low profile differential pressure transmitters.
CERTIFICATIONS
Transmitters meet numerous Agency requirements for hazardous area locations. Versions available to meet Agency flameproof and zone requirements.
Dual Seal certified to meet ANSI/ISA 12.27.01-2003 requirements.
HIGH DEPENDABILITY
Silicon strain gauge sensors successfully fieldproven in hundreds of thousands of installations.
Standard 5-year warranty
Adjustable Damping
Transmitter response time is normally 0.75 s, or the electronically adjustable setting of 0 (none), 2, 4, or 8 seconds, whichever is greater, for a 90% recovery from an 80% input step as defined in ANSI/ISA S51.1. (For 63.2% recovery, 0.50 s with sensors B to F, and 0.60 s for sensor A.)
European Union Directives
Complies with Electromagnetic Compatibility Requirements of European EMC Directive 2004/108/EC by conforming to the following EN and IEC Standards: EN 61326-1, and IEC 61000-4-2 through 61000-4-6.
Complies with NAMUR NE 21 Interference Immunity Requirement, and NAMUR NE 43 overrange and underrange annunciations.
Conforms to Applicable European Union Directives (“CE” Logo marked on product).
Electronics Housing and Housing Covers
Housing has two compartments to separate the electronics from the field connections. The housing and covers are made from low copper (0.6% maximum) die-cast aluminum alloy with an epoxy finish, or from 316 ss. Buna-N O-ring seals are used to seal the threaded housing covers, housing neck, and terminal block.
Electrical Terminations
Field wires enter through 1/2 NPT, PG 13.5, or M20 threaded entrances, as specified, on either side of the electronics housing. Wires terminate under screw terminals and washers on terminal block in the field terminal compartment as shown in Figure . Unused threaded field wire entrance is plugged to insure moisture and RFI/EMI protection.
Three- or Four-Wire Connections
Transmitter is supplied with a 4-wire terminal block, with the two negative terminals connected internally. This means that the transmitter can be wired with either three wires for wiring economy, or four wires for maximum accuracy. For relatively short wiring runs having low resistance, 3-wire connections can be used to minimize wiring costs. However, a voltage drop in the common lead carrying the power supply current will cause an error in the 1 to 5 V dc signal. For wiring runs with high resistance due to long lengths (or other reasons), or for maximum accuracy, a 4-wire connection may be used to provide input-output isolation. With 4-wire configurations, voltage drop in the power supply loop will have minimal effect on measurement.
email:1583694102@qq.com