8 - Connected PC with web browser or visualization software
9 - OPC server connectivity capabilities
10 - SCADA / BMS connectivity capabilities
11 - COM460IP capability: E-mail notification
12 - COM460IP capability:Web browser based navigation via the Internet
13 - COM460IP capability:SMS notification
Ethernet and Modbus/TCP Communication Modules
The COM460IP is a full-featured communication gateway for connecting BENDER devices to modern networks. The COM460IP connects via Ethernet connections to an existing communication network. The integrated web server displays the status of the entire network of BENDER devices, and may be viewed through the web browser (with Silverlight plugin installed) of any connected PC. No additional software is required. The COM460IP has many customizable options, including the ability to act as a Modbus/TCP gateway for status information.
Features
.• Modular, expandable gateway between BENDER communication bus and TCP/IP
• Gateway between BENDER communications bus and Ethernet
• Optional Modular/TCP communication gateway for status information of BENDER devices
• Customizable features available through options
• Capability for remote access via LAN, WAN, and Internet
Description
The FTC470XMB is a Modbus/RTU communication gateway for supported BENDER devices. Up to 10 BENDER devices may be connected to one FTC470XMB, and allows for full integration into existing Modbus/TCP communication systems.
The FTC470XMB is recommended for retrofitting existing systems with Modbus/ RTU networks. For a communication gateway supporting Modbus/TCP, please refer to the COM460IP.
Applications
• Remote communication of BENDER devices information to Modbus/RTU networks
• Control of BENDER devices via Modbus/RTU
• Connecting to Modbus/RTU compatible building management systems
Function
The FTC470XMB is integrated into a Modbus/RTU network as a slave device, and is integrated into the BENDER communication bus as either a master or a slave. The appropriate Modbus/RTU controller must be programmed to interpret the data from the FTC470XMB. A complete command syntax may be found in the FTC470XMB user manual.
Features
• Modbus/RTU communication gateway for supported BENDER devices
MK2000 Series LIM Remote Indicator
MK Series remote indicators are designed for use with the BENDER LIM2010 Line Isolation Monitor. A remote indicator duplicates audible and visual alarm indications on the LIM. All remote indicators include a green “SAFE” LED, a red “HAZARD” LED, and a “MUTE” button with an integral amber LED. The “MUTE” button is used to silence the remote audible alarm. Optionally, it can also be used to silence all audible alarms in the system.
Models with additional features include:
MK2000P
MK2000C: Amber “OVERLOAD”* alarm LED
MK2000CP: Amber “OVERLOAD”* alarm LED and test button
MK2000CBM: Amber “OVERLOAD”* alarm LED, test button, and digital displays showing THC reading and % isolation transformer load* in real-time
RAS Remote Annunciator Station
RAS series remote annunciator stations utilize multiple MK series remote indicators, each connected to a line isolation monitor. Included remote indicators may feature a built-in test button and a transformer overload* LED. Each remote indicator is powered directly by the LIM2010 line isolation monitor, located at the isolated power panel.
Advanced MK Series Remote Indicators
The universal remote alarm indicators and operator panels MK2430/MK800 are intended for visual and audible indication of operating status and alarm messages from BENDER systems including the LIM2010 and EDS series ground fault location evaluators. The MK2430/MK800 displays information regarding each individual device, system, or room and can define custom labels based on each individual application. A LIM test may also be preferred from these devices.
Alarm and Display Features:
Status and alarms are viewed on an easy-to-read LCD display. Features include:
• Normal operation indicator (green LED)
• Total hazard current
• Overload*
• Over-temperature
• Location of fault from EDS device
• Connection monitoring alarms
• Device errors• Test results
• Measured values
• Audible and visual indication
During normal operation, the MK2430/MK800 indicates the overall status of the system. The MK2430-11 features 12 digital inputs allowing messages from other technical equipment to be recorded and displayed.
Dual Display Digital Clock and Timer
The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both the time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required.
Digital Clock or Timer
The Clock/Elapsed timers are complete microprocessor based units that display either time of day or elapsed time information. The ZT1591 has a large 2-1/2“ 7 segment display with large bright red LED characters that are easily read in high ambient light.
The BENDER ZT1591 operates independent of line frequency. This unit has unique power backup systems that requires no battery so there is no need for battery monitoring and replacement. In the event of power outage, both clock and timer functions will continue to work for at least 24 hours. However, the displays are not visible during this time interval.
Email:wang@kongjiangauto.com