WOODWARD LSOV25 Liquid Fuel Shutoff Valve

F: | Au:FAN | DA:2025-06-17 | 697 Br: | 🔊 点击朗读正文 ❚❚ | Share:

WOODWARD LSOV25 Liquid Fuel Shutoff Valve

Product overview

WOODWARD LSOV25 liquid fuel shut-off valve is a critical safety component designed specifically for industrial gas turbines and other equipment, playing an indispensable role in ensuring stable operation and safe production of the equipment. Its design aims to quickly cut off all liquid fuel flows, effectively preventing fuel leakage to the turbine, thereby avoiding potential safety hazards and equipment damage.


Product Structure and Working Principle

(1) Structural Design

Overall structure: LSOV25 belongs to a three-way, two-stage valve structure. The valve body is made of anodized aluminum material, which not only has good corrosion resistance and can adapt to various complex working environments, but also has a relatively light weight, making it easy to install and maintain. All internal moving parts are made of hardened stainless steel to ensure high wear resistance and reliability during long-term and frequent operation, reducing the probability of failure caused by component wear.

Key component: The valve is equipped with a flushing flow filter inside, which can effectively block pollutants with a particle size exceeding 40 μ m (nominal), prevent them from entering the pilot valve section, avoid damage to the pilot valve, and ensure the normal operation of the entire valve. At the same time, the setting of the filter screen will not have a significant filtering effect on the normal fuel flow, ensuring that the fuel can pass smoothly through the valve.

(2) Working principle

Normal working state: In the normal working state when powered on, the valve remains open, and fuel can flow in normally from the inlet and be delivered to the corresponding position according to the equipment operation requirements, meeting the continuous supply of fuel for gas turbines and other equipment.

Cut off working mechanism: When the current of the solenoid valve terminates, the valve will quickly respond. This valve utilizes supply pressure to achieve complete cut-off of fuel flow and can complete this operation in 0.09 seconds or less. The closing process of the valve is completed by the combined action of spring compression and auxiliary supply pressure. At the moment of power outage, the spring quickly releases its elastic force and cooperates with the supply pressure to push the relevant components to move, quickly cutting off the fuel passage and bypassing all fuel entering the valve to the return system, effectively preventing the fuel from continuing to flow to the turbine and avoiding possible dangerous situations such as turbine overspeed and abnormal combustion caused by fuel loss of control.

HVACSTAR 2001-12E2U1B1S1A Diesel Fuel Shutoff Solenoid Valve for ...

Product specifications

Voltage configuration: To meet the electrical requirements of different devices and systems, this valve offers four voltage configuration options, namely nominal voltage of 24 Vdc, 125 Vdc, and also available in 115 Vac or 220 Vac versions. Users can flexibly adapt according to the power type of the actual usage scenario.

Pressure parameters: During normal operation, the valve is designed to withstand a maximum supply pressure of up to 1200 PSI (8274 kPa), which can meet the working requirements of high-pressure fuel delivery systems. Its designed pressure resistance is stronger, capable of withstanding a verification pressure of 1800 PSI (12 411 kPa) and a burst pressure of 6000 PSI (41 370 kPa). Even under extreme pressure conditions, it can ensure the structural integrity of the valve and prevent serious failures such as rupture.

Flow parameters: Based on MIL-C-7024 calibration fluid from the United States, tested at 70 ° F (21 ° C), the rated flow rate of the valve is 30000 lb/h (13600 kg/h), which can meet the basic requirements of fuel flow for most industrial gas turbines under different operating conditions.

Fuel compatibility: This valve has excellent fuel compatibility and can be used with almost all common fuels, including diesel, methanol, ethanol, Jet "A" aviation kerosene, regular kerosene, # 2 household heating oil, heated light crude oil, and residual fuel. Moreover, within the prescribed pollution limits, the valve can operate normally, ensuring stable operation even if the fuel contains a certain amount of pollutants.

Temperature range: The valve can adapt to a fuel temperature range of 0 to+250 ° F (-18 to+121 ° C), and can operate normally under a wide range of temperature conditions, meeting the fuel control needs of different seasons and working environments.

Cycle life: After rigorous testing and practical application verification, the cycle life of this valve can reach 10000 times, with high durability, reducing the cost and maintenance workload caused by frequent valve replacement.


PRODUCT FUNCTION

Quick cut-off function: It can cut off fuel supply in a very short time (0.09 seconds or less), ensuring that in emergency situations such as equipment failure, control system issuing shutdown commands, or detecting abnormal conditions, the delivery of fuel to the turbine can be quickly stopped, effectively preventing accidents from occurring or expanding.

Fault safety function: The valve design follows the principle of fault safety. Once the electrical signal is lost or terminated, the valve will automatically bypass all incoming fuel to the return system, ensuring that the system is in a safe state. This design greatly improves the safety and reliability of equipment operation, reducing the risk of fuel loss due to electrical faults.

Protection function: mainly used to protect the turbine in the event of normal fuel control failure for any reason. If the valve cannot cut off the fuel supply to the turbine normally, it may cause serious overspeed problems, leading to mechanical damage and even personal injury. Therefore, the LSOV25 liquid fuel cut-off valve is an important line of defense to ensure the safe operation of equipment such as gas turbines.


Product advantages

High reliability: Using high-quality anodized aluminum shell and hardened stainless steel internal components, combined with advanced design and manufacturing processes, the valve has excellent durability and fatigue resistance, and can operate stably in harsh industrial environments for a long time, reducing equipment failure and maintenance frequency.

Rapid response: The fuel cut-off action can be completed within 0.09 seconds. This rapid response capability can respond to various emergency situations in a timely manner, effectively reducing potential risks caused by fuel loss of control and ensuring the safety of equipment and personnel.

Wide fuel adaptability: Compatible with various types of fuels, whether it is common diesel, kerosene, or some special fuels, it can work normally under specified conditions without the need to customize valves separately for different fuel types, improving the product's versatility and application range.

Complete safety design: Fault safety function and quick cut-off mechanism provide safety guarantee for equipment operation from multiple aspects, comply with strict industrial safety standards, and make users feel more at ease during use.


Application scenarios

In the field of power generation: In gas turbine power plants, the LSOV25 liquid fuel cut-off valve is a key component to ensure the safe operation of power generation equipment. When the generator set malfunctions, such as control system failure, abnormal turbine vibration, or overheating, the valve can quickly cut off the fuel supply, avoiding more serious accidents and ensuring the stability and continuity of power supply.

Industrial drive equipment: For gas turbines that drive industrial machinery such as compressors and pumps, LSOV25 valves also play an important role. During the operation of the equipment, if unexpected situations arise, such as mechanical component damage that may affect the normal control of fuel supply, valves can promptly cut off the fuel to prevent further damage to the equipment and protect the safety and stability of the entire industrial production process.

Marine ship power system: In the gas turbine power system of marine ships, due to the complex and ever-changing marine environment, the equipment requires extremely high safety and reliability. The LSOV25 liquid fuel cut-off valve can quickly cut off fuel in emergency situations such as severe sea conditions and equipment failures, ensuring the safety of the ship's power system, avoiding fire, explosion and other hazards caused by fuel leakage or loss of control, and ensuring the safety of ship navigation.

  • Basler BE1-57/27R Solid State Protective Relay
  • Basler BE3-25AX Time Overcurrent Relay
  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System
  • Basler BE1-60 Voltage Balance Relay
  • Basler Electric CBS 212 Current Boost System Sensing 120/240VAC 50/60Hz 10VA
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler SSR125-12 Static Voltage Regulator 918500102
  • Basler SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric 9110000113 Excitation Module
  • Basler Electric 90-72300-114 Control Accessory
  • Basler Electric PRS-250 Protection Relay System
  • Basler Electric BE1-50/51M-109 Overcurrent Relay
  • Basler Electric SR4A1B10B3E Static Voltage Regulator
  • Basler Electric CBS 212 Current Boost System
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric MOC2207 Motor Operated Potentiometer
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F
  • Basler BEI-81 Underfrequency Relay
  • Basler CBS 212A Current Boost System
  • Basler SSR 63-12 Static Voltage Regulator
  • Basler DGC-2020 Digital Genset Controller
  • Basler BE1-32 Reverse Power Relay
  • Basler BE1-50/51B-207 Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler L304KC Protective Relay
  • Basler BE3-25-1S1N4 Time Overcurrent Relay
  • Basler 9032300113 Excitation Support System
  • Basler BE1-59N Ground Overvoltage Relay
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler MOC2102 Potentiometer
  • Basler BE1-87G Generator Differential Relay
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS 125-15-B2C5 Digital Excitation System
  • Basler Electric PLA2400-12GM Power Supply
  • Basler Electric BE1-50/51B-235 Overcurrent Relay
  • Basler Electric BE1-27/59 Undervoltage Overvoltage Relay
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE1-32R Solid State Power Relay
  • Basler Electric BE1-700 Digital Generator Management Relay