After connecting the frequency converter via USB, create a project in MOVISUITE, select the "USB" network type, and perform a scan. The identified devices can be imported into the project and managed in the network view or functional view.
5.2 MOVIKIT ® Application of software modules
To reduce debugging complexity, SEW provides pre configured MOVIKIT ® Software module:
MOVIKIT ® Velocity Drive: Implement speed control and standardize process data interfaces;
MOVIKIT ® Positioning Drive: Supports multiple motion modes such as jog, parameter search, linear/modulus positioning, etc.
Using the MOVIKIT module can significantly reduce debugging time without the need for in-depth understanding of underlying data mapping. The corresponding example projects can be downloaded from the official website.
5.3 Process Data Source Configuration
If the MOVIKIT module is not used, manual configuration of process data sources and data word allocation is required. In the equipment configuration of MOVISUITE, clearly set the value source (such as PROFIBUS) and allocate the actual value feedback channel.
Communication diagnosis and fault handling
6.1 LED status indicator light
BF (Bus Fault): Constant red indicates communication interruption; 2Hz flashing indicates that the device has not been addressed by the main station;
RUN: Green indicates that the bus hardware is normal; The red flashing indicates an address setting error (0 or>125).
6.2 Diagnostic Alarm Function
PROFIBUS supports diagnostic alarms and can be enabled in TIA Portal. When the equipment malfunctions, the fault code and description will be uploaded through diagnostic messages for quick problem identification.
6.3 MOVIKIT Diagnostic Monitor
The built-in diagnostic monitor provides "monitoring mode" and "control mode":
Monitoring mode: Real time viewing of process data exchange status;
Control mode: The set values can be directly issued through a PC for offline testing. Before switching to control mode, it is necessary to ensure that the driver is in a disabled state to prevent accidental actions.
Equipment replacement and data migration
MOVIDRIVE ® The frequency converter supports replaceable memory modules (located in the device slot). After debugging is completed, all parameters, software module configurations, bus settings, and addresses are stored in this module. When replacing the device, simply insert the module into the new device and restart it to restore all settings without the need for reconfiguration, greatly improving maintenance efficiency.
Summary and Best Practice Suggestions
Successfully integrated MOVIDRIVE ® The key to converting a frequency converter to a PROFIBUS network is:
Strictly follow the EMC installation specifications to ensure the stability of the communication physical layer;
Use official GSD files and the latest software tools to avoid compatibility issues;
Make good use of MOVIKIT module to improve standardization and debugging efficiency;
Make full use of diagnostic tools to quickly locate network and equipment failures;
Adopting memory module backup configuration to simplify the device replacement process.
PROFIBUS, as a mature industrial fieldbus, is widely used in MOVIDRIVE ® With the support of frequency converters, high reliability and real-time motion control communication can be achieved. Through the steps and methods described in this article, engineers can systematically complete the entire process from hardware installation to software debugging, providing stable and efficient driving solutions for automation systems.