Phoenix FL MC 1000 SC (ST) Fiber Optic Converter

F: | Au:FAN | DA:2026-04-08 | 595 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Working temperature: 0 ° C... 60 ° C

Storage temperature: 0 ° C... 70 ° C

Relative humidity: 5% 95% (no condensation)

Working pressure: 66 kPa... 108 kPa (corresponding to a maximum altitude of 4850 meters)

Protection level: IP20

Protection category: Class 3 (VDE 0106/IEC 60536)

Vibration tolerance: Complies with IEC 60068-2-6, 10... 150 Hz, 5g

Impact resistance: Complies with IEC 60068-2-27, 30g, 11ms (during operation)

Free fall: compliant with IEC 60068-2-32, 1 meter

Electromagnetic compatibility: Complies with IEC 61000-6.2 (industrial environment immunity standard)

These specifications indicate that the FL MC 1000 series is capable of long-term stable operation in typical industrial control cabinet environments, withstanding common mechanical vibrations and electromagnetic interference.


Installation and Wiring Guide

5.1 DIN rail installation

Installation: Hang the module from top to bottom onto the NS 35 DIN rail, ensuring that the upper fixing claws hook onto the upper edge of the rail; Then push the module towards the installation surface until you hear a "click" sound, indicating it is tightened. After installation, check for firmness.

Disassembly: Use a suitable tool (such as a screwdriver) to insert the locking claw and pull it down; At the same time, pull the module out slightly and then lift it up to remove it.

End clamp: It is recommended to install universal end clamps (E/NS 35 N, order number 0800886) on both sides of the module to prevent the module from sliding on the guide rail.

5.2 Power Wiring

Use 0.2 Connect a 2.5 mm ² wire to the power terminal (note polarity:+24V and 0V).

It is recommended to connect the DIN rail to the protective earth (PE) through the grounding terminal, as the module housing is grounded through the rail.

The torque for tightening the screw is 0.5 .. 0.6 Nm。

5.3 Ethernet cable connection

Insert the standard RJ45 plug into the front panel port. Due to the support for automatic crossover, there is no need to worry about straight or crossover lines.

Gently pull the cable to confirm a secure connection.

5.4 Fiber optic cable connection

Cleaning: Before connecting, ensure that the fiber optic plug is clean, and specialized cleaning tools can be used.

Alignment: Align the SC or ST connector correctly (pay attention to the positioning key) and insert it into the fiber port. For SC duplex connectors, it is usually necessary to ensure that the transmit (Tx) and receive (Rx) channels are cross connected with the other end (i.e. the local Tx is connected to the opposite Rx).

Fixed: For ST connectors, lock them by rotating a quarter turn after insertion; For SC connectors, simply push them in and the buckle will automatically lock.

Attention: Strictly follow the fiber manufacturer's minimum bending radius, maximum tensile force and other parameters to avoid signal attenuation or fiber breakage.

Detailed explanation of configuration and diagnosis

6.1 Basic configuration steps

Check the DIP switch settings (usually all bits are set to OFF by factory default).

Connect the power and observe if the US LED is constantly on.

Connect the RJ45 cable and observe whether the LNK/ACT and 10/100 LED are indicating the link and speed normally.

Connect the fiber optic cable and check if the other end device can establish a link. If the link is not working, try enabling DIP 1 (LFPT) or checking the fiber optic cross connection.

6.2 Typical Configuration Scenarios

Scenario 1: Connecting to a standard switch: Set DIP 2 to OFF (self negotiating), and the converter will automatically negotiate 100M full duplex with the switch. This is the most commonly used configuration.

Scenario 2: Connecting an old 10M device: Set DIP 2 to ON (forced mode), DIP 3 to ON (10Mbps), and DIP 4 to OFF (full duplex) or ON (half duplex) as needed.

Scenario 3: Enable Global Link Diagnosis: When using two FL MC 1000s connected back-to-back via fiber optic, set DIP 1 on both devices to ON. This way, any link failure on either side will cause both electrical ports to shut down simultaneously, notifying the terminal device.

6.3 Troubleshooting

Possible causes and solutions for the fault phenomenon

The US LED does not light up. The power supply is not connected or the voltage is too low. Check the power supply wiring and voltage (>12V is required)

LNK/ACT does not light up, RJ45 link not established. Check if the network cable is intact and if the other end device is powered on. Try replacing the crossover/straight line

Ensure Tx Rx cross connection due to fiber link failure, incorrect fiber connection or excessive attenuation; Clean the fiber optic end face; Check the bending radius; Calculate optical power budget

Check DIP 2-4 settings for low communication rate, duplex mismatch, or interference to ensure consistent self negotiation or forced settings at both ends; Check the quality of the network cable


Order information and attachments

7.1 Main products

Describe model, order number, packaging quantity

Fiber optic converter, SC connection, 1310nm, multimode FL MC 1000 SC 2891320 1

Fiber optic converter, ST connection, 1310nm, multimode FL MC 1000 ST 2891321 1

7.2 Recommended attachments

  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC
  • SIGMATEK SDD310-23 VARAN Servo Drive
  • SIGMATEK CDM 163 and CIC 011 C-DIAS Input Modules
  • SIGMATEK MDP 101-1 Power Module
  • SIGMATEK CM5V020 Wiring Circuit with CTMS020
  • SIGMATEK CCP521 C-DIAS Processor Module
  • SIGMATEK MDP 101-K Power Module
  • SIGMATEK ETEK C-IPC 733MHz VIA Eden 7000
  • SIGMATEK DCP 643 DIAS PLC CPU Module
  • SIGMATEK TAE121 12-200-121 Operator Terminal
  • Sigmatek TMS012-T Injection Moulding Technology Module
  • Sigmatek MDD 121-1 Controller
  • Sigmatek CDM167 Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek ETT731 Built-In Terminal Touch
  • Sigmatek CCP521 C-DIAS Processor Module
  • Sigmatek Krauss Maffei PC301-K Control Cabinet PC
  • Sigmatek CIC-21 C-DIAS CAN Module
  • Sigmatek CIO-011 Multi I O Module
  • Sigmatek 01-450-152D C-IPC 152 Industrial PC
  • SIGMATEK 01-450-024 C-IPC 128MB VIA 733MHz
  • SIGMATEK CCL-081 C-DIAS Processor Module
  • SIGMATEK CP311 20-004-311 Module
  • SIGMATEK EP00000262 SLIDES MIDI I O-V3 Controller
  • SIGMATEK TMS012-T Slides Technology Module
  • SIGMATEK MDD111-1 Drive Axis Module
  • SIGMATEK MDP101-1 PLC Module
  • SIGMATEK CP111 S-DIAS Processor Module
  • DEMAG ErgoControl Sigmatek NC4 Display Unit
  • SIGMATEK DCP642 Module
  • Sigmatek Demag NC4 9617.067.03 Control Module
  • Sigmatek DCP 643 Central Processing Unit
  • Sigmatek VI 021 S-SLIDES VARAN Interface Module
  • Sigmatek SDD340-46 Servo Drive 14kVA
  • Sigmatek DSI021 Slide Siemens Interface
  • Sigmatek CCL912 C-SLIDES CPU PSU Module
  • Sigmatek ETV1521 VARAN Control Panel
  • Sigmatek ET322 Operator LCD Terminal
  • Sigmatek MDD1111 DIAS Drive Module
  • Sigmatek CAM123 Module
  • SIGMATEK CP111 VARAN Ethernet Controller
  • SigmaTek MDD 111 Axle Module
  • SIGMATEK CIO013 C-DIAS I O Module
  • SIGMATEK AKM52K-ANC2GBB0 Servomotor 640VDC
  • SIGMATEK ETT321 01-230-321 Touch Screen
  • SIGMATEK NC4Kompakt 01-250-010-D Safety Controller
  • SIGMATEK CIO011 C-DIAS Multi I O Module
  • SIGMATEK MDD 121-1 Drive Axis Module
  • SIGMATEK CDM163 Control Module
  • Sigma-Tek 4000HR-3 Heading Reference Directional Gyro
  • Sigmatek DIAS DAI 883 Analog Input Module
  • Sigmatek 0332.554.03 Printed Circuit Board Card
  • Sigma Tek 5000B-36 Attitude Gyro 8130
  • Demag NC4 0332.554.03 Sigmatek Control Board
  • Sigmatek IPC Pentium 300 CF Industrial PC
  • Sigmatek MDP 102 PLC Module
  • Sigmatek DTO163 Digital Output Module
  • Sigmatek PCT151 Touch IPC 15 Panel and I-PC C300
  • Sigmatek CCL911 CD Processor Module
  • Sigmatek SCP011 S-DIAS Safety CPU Module
  • Sigmatek SE051 Network Splitter Module
  • Sigmatek CIO011 C-DIAS I O Module
  • Sigmatek SE051 Ethernet Splitter
  • Sigmatek CCL911 CD Processor Module
  • Sigmatek SDD310-4 DIAS Drive 14kVA
  • Sigmatek CTMS020 C-DIAS Technology Module
  • Sigmatek CTMS020 CD Technology Module
  • Sigmatek CTO167 C-SLIDES Digital Output Module
  • Sigmatek C-IPC 152 Industrial PC
  • Sigmatek SDD310-4 SLIDES Drive 310
  • SIGMATEK MDP 102-1 DIAS Power Module
  • SIGMATEK SCP111 S-DIAS Safety CPU Industrial
  • SIGMATEK CAO081 Analog Output Module
  • SIGMATEK DCC080L Control Module
  • SIGMATEK MDP101-1 Power Module
  • SIGMATEK SCP111 S-DIAS Safety CPU
  • SIGMATEK PC325-K Industrial PC
  • SIGMATEK ETT 731 Operator Terminal
  • SIGMATEK DSV011 SLIDES Hub Module 05-023-011
  • SIGMATEK 12-780-012 R8-IPC Industrial Computer
  • Sigmatek SE051 Ethernet Splitter
  • Sigmatek DAI 883 DIAS Analog Module
  • Sigma Tek 4000B-30 Directional Gyro
  • Sigmatek CP112 S-DIAS Processor Module
  • Sigmatek SDD310 DIAS Drive
  • Sigmatek SDD120-23 DIAS Drive 14kVA
  • Sigmatek C-IPC 152 Industrial PC
  • Sigmatek CIV513 VARAN Control Module
  • Sigmatek DCP 082 Processor Module
  • Sigmatek C-IPC Industrial PC 01-450-023 GEB
  • SIGMATEK PC572 Operating Terminal
  • SIGMATEK DCC041 DIAS Compact Controller HW 6.10
  • SIGMATEK C-IPC 152 1GB Celeron M440 Controller
  • SIGMATEK 01-310-322-K PC322-K Industrial PC
  • SIGMATEK TAE732-P Touch Screen Operator Panel
  • SIGMATEK 01-018-100 Control Module
  • SIGMATEK DDI-164 Digital Input Module
  • Sigma-Tek 5000B-36 Artificial Horizon
  • SIGMATEK 12-780-012 R8-IPC Geode LX800 Computer
  • SIGMATEK CTMS 020 Servo Drive
  • Sigmatek MDD121-1 Controller
  • Sigmatek ETV1021-L VARAN Terminal
  • Sigmatek DST022 DIAS Module
  • Sigmatek CCP512-K C-Dias Processor Module
  • Sigmatek SRO 021 Relay Output Module
  • Sigmatek SDI 101 Digital Input Module
  • Sigmatek IPC 221 Industrial PC
  • Sigmatek DNC-305 Digital Input Module
  • Sigmatek SDD335 DIAS Drive
  • Sigmatek C-IPC Industrial Controller
  • SIGMATEK 01-450-031 C-IPC 256MB LX800 Computer
  • SIGMATEK SDD310-3 DIAS Drive 310
  • SIGMATEK DSV011 SLIDES Hub Module 05-023-011
  • SIGMATEK CNC031 CD Analog Module 12-011-031
  • SIGMATEK 01-450-031 C-IPC 256MB LX800
  • SIGMATEK 01-450-026 C-IPC VIA 733MHz Controller
  • SIGMATEK DCP-643 DIAS CPU Module with DKL-003
  • SIGMATEK MDD111-L DIAS Drive Axis Module
  • SIGMATEK SDD310-23-L DIAS Drive 310
  • SIGMATEK Viscotec ETV0551 Touch Panel
  • SIGMATEK PC321K Industrial Computer
  • SIGMATEK MDP 102-1 SLIDES Power Module
  • SIGMATEK TAE-151 12-200-151 Light Terminal
  • SIGMATEK CP102 20-004-102P6995B HMI Panel
  • SIGMATEK CAM-123 12-017-123-C Analog Mixing Module
  • SIGMATEK DCC041 DIAS Compact Controller
  • SIGMATEK DVI021 and DKL015 DIAS Power Module
  • SIGMATEK SDD340-46 SDD Series Servo Drive