Product Overview and Application Scenarios
VCP 08 is a compact machine operator terminal used to start various functions of a machine according to application requirements, and can visualize the operation information of the machine/equipment. Its outstanding features lie in its compact structural design and back surround sealing ring, making it widely applicable and supporting any installation posture.
Depending on the variant configuration, this small operating terminal is equipped with either three serial standard interfaces or one fieldbus interface. The front panel adopts a short stroke keyboard, made of 3mm aluminum plate with beveled edges, covered with chemically resistant polyester film on the surface and embossed with key areas.
VCP 08 is developed for single axis or multi axis control tasks, with typical applications including:
Handling and assembly systems
packaging machinery
Printing and paper processing equipment
machine tool
Use boundaries and taboos
VCP 08 is only allowed to operate in a specified posture under specified assembly, installation, and environmental conditions (temperature, protection level, humidity, EMC requirements, etc.). Prohibited usage scenarios include:
Operating conditions that do not meet the specified environmental conditions (such as underwater, extreme temperature fluctuations, or ultra-high temperature environments);
Use without explicit permission from Bosch Rexroth;
Only the accessories and components specified in this manual are allowed to be used, and components not explicitly listed (including cables and wires) shall not be installed or connected;
Only allow to run according to the software and firmware configuration specified in the functional description.
Special attention should be paid: VCP 08 belongs to Protection Class I equipment and must use protective grounding. It is strictly prohibited to use it in scenarios such as construction cranes, passenger and cargo elevators, personnel transportation equipment, medical applications, refineries, hazardous material transportation, nuclear applications, high-frequency sensitive occasions, mining, food processing, and protective device control. The prerequisite for device startup debugging is that the entire machine complies with the regulations, safety standards, and norms of the country where it is located.
Hardware and electrical specifications
3.1 Structure and Panel
Project specifications
Galvanized steel plate for the casing
Front panel aluminum spray painted, 209 × 159 × 3 mm (H × W × D)
Facial mask polyester film
Sealed back circular rubber sealing ring
Installation opening 199 × 139 mm (H × W)
Installation depth is approximately 58mm (excluding connectors)
Protection level: Front IP54/Back IP20
The total weight is about 800 grams
3.2 Display
LCD module with LED backlight, resolution of 120 × 32 pixels, black pixels/yellow green background, viewing angle of 90 °. The contrast setting has temperature compensation function, and the LCD lifespan and backlight half-life are both 100000 hours. Standard font 4 lines x 20 characters (character matrix 6 x 8 pixels), enlarged font character matrix 12 x 16 pixels, display area 38 x 119 mm.
3.3 Keyboard
36 key short stroke button with tactile feedback; The button area is 16 × 16 mm, the stroke is 0.5 mm, the operating force is 2-3 N, and the switch life is about 1 million times.
3.4 Electrical Parameters
Power supply: 24 V DC (SELV compliant with DIN EN 61131), maximum residual ripple of 10%;
Voltage range: 19.2 V -30.2 V;
Power consumption<0.3 A, peak current<0.5 A, connected to a load of approximately 10 W;
Built in semiconductor fuse (self resetting) and reverse polarity protection.
3.5 CPU and Storage
Central processing unit Z84, clock frequency 10 MHz, equipped with watchdog timer, real-time clock, display temperature compensation, and battery monitoring functions. The application memory is 256 KByte Flash, and the RAM is 128 KByte static CMOS-RAM (battery backup).
3.6 Environmental conditions
Operating temperature: 0 ° C to 50 ° C; Storage/transportation: -20 ° C to+70 ° C;
Relative humidity: 10% -95% (no condensation);
Application area: Pollution level 1, overvoltage category II.
3.7 Compliance with Standards
The equipment complies with EN 61131 (equipment requirements, storage and transportation, power supply), EN 60529 (protection level), EN 60068 Part 2-27 (impact) and Part 2-6 (sinusoidal vibration), IEC 60068 (corrosion protection), EMC meets Directive 89/336/EWG and all amendments, immunity covers EN 61000-4-2/-3/-4/-5/-6, and emission interference meets EN 50081-1 Table A1, EN 55011 and EN 55022.
In addition, although the Rexroth control device is developed and tested at an advanced level of technology, it cannot track the development of all materials that may come into contact with the equipment. Therefore, before using new lubricants, cleaning agents, and other materials, compatibility testing must be conducted on the casing/casing material.
Installation and wiring specifications
4.1 Mechanical Installation
During installation, a gap of at least 30mm must be left around the operating terminal to ensure air circulation. When installing horizontally, attention should be paid to other heat sources below the terminal that may cause heat accumulation. Adequate heat dissipation must be provided and the allowable temperature range specified in the technical data must be followed.
To maintain the specified level of protection, it is necessary to ensure that the sealing ring is evenly attached to the installation surface, and the hex nut is tightened evenly, with a maximum torque not exceeding 1.2 Nm. Installation steps: Thread the terminal through the installation opening from the front, and then fix it with the hex nut from the back. This method is particularly recommended for distribution cabinet panels with a thickness of approximately 1 mm to 8 mm. Fasteners include press in M4 × 18 mm bolts, DIN 127 Form B B4 spring lock washers, and M4 DIN 934 nuts (the latter two are not provided with the equipment).
4.2 Power Supply Connection
Power is supplied through connector X1 (Phoenix COMBICON MSTBV 2,5/3-GF, randomly provided MSTB 2,5/3-STF female plug):
Pin 1: Low Noise Ground
Pin 2:0 V
Pin 3:24 VDC
The device has reverse polarity protection - the device does not work when the polarity is reversed. The power cable must use thin stranded wire with a minimum cross-sectional area of 0.75 mm ² (18 AWG) and a maximum cross-sectional area of 2.5 mm ² (14 AWG). Wiring steps: Peel off the outer layer by about 30 mm and the core wire by about 5 mm, install a wire end sleeve, and connect it to the connector; If shielded power cables are used, the shielding layer should be connected to Pin 1; Insert the female plug into X1. A and lock it with screws to prevent slipping.
4.3 Protection Grounding
The protective grounding bolt must always provide an independent conductor with a minimum cross-sectional area of 1.5 mm ² (16 AWG) and as short as possible - meeting this requirement can enhance operational safety.
4.4 Panel Cleaning
Only use a damp cloth to remove panel stains.

Detailed explanation of interface system
The equipment is divided into two categories: standard type and bus type. The universal interface X3 integrates multiple interface standards into one connector, divided into two channels: the communication channel (SER1) is independent of the upload/download/record printer/scanner channel (SER2). SER1 only allows one of the three interface standards.
Model code RS232c (X3-SER2) TTY/20mA, RS485, RS232c (X3-SER1) DeviceNet INTERBUS PROFIBUS DP
VCPxx.xxxx-xxxRS-xx-xx X X - - -
VCPxx.xxxx-xxxDN-xx-xx X - X - -
VCPxx.xxxx-xxxIB-xx-xx X - - X -
VCPxx.xxxx-xxxPB-xx-xx X - - - X
5.1 Standard Interface
TTY/20 mA current loop (X3-SER1): It can be wired as an active or passive current loop, with independent 20 mA power supplies for each transmitting and receiving line, and a compliant voltage of approximately 24 VDC. The 20 mA power supply should be provided by the transmitter unit to significantly reduce signal line crosstalk. When in idle state (logic 1), a current of 20 mA can be measured in the cable. 25 pin D-SUB female socket, passive mode key pins: Pin 10 T+, 13 R+, 14 R -, 19 T -; Active mode adds Pin 12 S1+, 16 S2+, 21 S1-, 24 S2-. The RS485 terminal must be set to OFF in current loop mode.
RS485 (X3-SER1): Suitable for point-to-point and multi-point connections. Logic 1: UA-UB ≤ -0.3V (UA<UB); Logic 0: UA-UB ≥+0.3V (UA>UB). Key pins: Pin 8 T (A), 9 T (B), 11 SGND, 22 R (A), 23 R (B). Terminating resistors R1/R3=510 Ω, R2=150 Ω, R4=120 Ω. The point-to-point connection must activate the termination; Multi point connection only activates termination at the end of the cable. The termination switches S1-S4 are all ON for effective termination, and all OFF for closed. Only specified switch positions are allowed.
RS232c (X3-SER1): point-to-point connection, pins 6 TD, 15 CTS, 17 RTS, 18 RD, 25 SGND; RS485 termination must be turned off in RS232 mode.
RS232c (X3-SER2): Only for downloading, uploading, scanning, or recording printers, as this interface does not have electrical isolation. Pin: 1 low-noise ground, 2 TD, 3 RD, 4 RTS, 5 CTS, 7 SGND, 20 DTR.
5.2 Bus interface
DeviceNet (X2.1/X2.2): Compliant with ISO 11898, electrically isolated. 9-pin D-SUB (with the same allocation of male and female pins), key pins: Pin 2 CAN_L, 3/6 CAN_GND, 7 CAN_S. All signal lines should be looped from X2.1 to X2.2, and the connecting cables should be connected to every pin, including reserved pins, so that the cables can still be used when future bus specifications are expanded. DeviceNet certified cables must be used: 2 × 1.1 mm type loop resistance<22.6 Ω/km, 2 × 0.6 mm type<91.8 Ω/km, surge impedance of 120 Ω, unit length capacitance<39.4 pF/m. The longest branch line is 6 meters; The bus length varies with baud rate: a 2 × 1.1 mm cable can reach 500 m at 125 kBit/s, and only 100 m at 500 kBit/s. The two ends of the bus are terminated with 120 Ω resistors. Diagnostic LED: green off=terminal disconnected from bus, green on=communication activated, green flashing=occasional bus error.
INTERBUS (X2.1/X2.2): Electrical isolation. X2.1 is a Remote bus input (male socket): Pin 1 DO, 2 DI, 3 GND, 6/DO, 7/DI; X2.2 for Remote bus output (female socket): Add Pin 5+5V power supply and Pin 9 RBST (remote bus status). Shielded twisted pair cables (LiYCY TP type) must be used, with the maximum length depending on the application location in the INTERBUS topology. Diagnostic LED: RC green light=remote bus check; +5V green light indicates normal power supply, off indicates no power supply; BA green light=bus activated, off=bus not activated; RD red light indicates that the remote bus is not activated.
PROFIBUS DP (X2): Electrical isolation. 9-pin female socket: Pin 3 RxD/TxD-P, 4 CNTR-P, 5 DGND, 6 VP (powered by the terminal connector), 8 RxD/TxD-N, 9 CNTR-N. Class A PROFIBUS DP certified cables according to EN 50170 can be used: impedance 136-165 Ω, capacitance<30 pF/m, loop resistance 110 Ω/km, wire diameter 0.64 mm. The maximum cable length depends on the baud rate (DIN EN 19245 Part 3): 187.5 kbit/s 1000 m, 500 kbit/s 400 m, 1500 kbit/s 200 m, 3000-12000 kbit/s 100 m. The two ends of the bus must be terminated - when using a dedicated PROFIBUS connector, the termination resistor is usually integrated into the connector. Diagnostic LED: Green=Communication activated.
5.3 D-SUB connector shielding
All D-SUB connectors must be fully shielded: the shielding layer must be folded back and flattened along the cable sheath; When fixing cables with cable clamps, the shielding layer should be in contact with the casing as much as possible and ensure sufficient stress relief.
Display and operation components
6.1 Contrast setting
Set the system variable LcdFntrast in any screen through programming software, with a value range of -25 to+70 and a default value of+25. If this variable is not configured, the default value will be used during device initialization. On site adjustment steps: Press the data release button → enter the new value using 0-9 or plus/minus keys → press Enter to confirm (immediate effect) → press the data release button again; Repeat as necessary until satisfactory.
The recovery process when the contrast cannot be read from the image: Shut down → Set the user mode switches S1 and S4 to ON → Power on → Shut down after a warning appears → Set S4 to OFF → Power on again. The application will not be lost. The default contrast switch position is the same as the "Hardware Activation Download" position, and the reset occurs before the corresponding message is displayed. The warning will be presented in a readable manner.
The screen characters support two attributes, Normal and Flashing, and the font can be Normal, Zoom, or a custom character set.
Safety reminder: When the display screen is damaged, avoid contact, swallowing, or inhaling liquids or gases that may leak (risk of poisoning and corrosion).
6.2 Keyboard Functions
The buttons are located under the environmentally resistant polyester film, and the button operation logic is defined in the programming software:
Edit key: First press the data release key to activate the editing mode (LED lights up). The number keys 0-9 can be used in conjunction with Shift/ShiftCase system variables to input A-Z, parentheses, °,:? Oh! Characters such as<,=,>, , *,/, etc;
Navigation keys: The left/right cursor keys can be programmed to directly select adjacent nodes and I/O screens (move the cursor by one character in the editor); The up/down keys are used for variable selection; The Home button returns the position of the parent node or the first input variable;
Special key: The Help key always displays the current online help (flashing LED indicates the presence of a message); The Print key activates the print job as a soft key; The Quit key is a message confirmation key; Enter to end data input (press in the startup screen to open the settings screen); Switch between menu and editor for Data release (the edit mode LED lights up, press again in edit mode to exit); Delete removes the character under the cursor and removes the selected message from the data storage;
Function keys F1-F12: Functions can be freely assigned (soft key functions), which can be used as menu direct keys or trigger control system functions. A set of identification label strips (F1-F12 label strips+one blank strip) are provided with the device, which can be replaced after disassembly. They can be inserted from the back of the panel without affecting the specified seal. Label method: Handwritten with waterproof pen for individual/prototype, laser printed copy film for small batches, and customized label strips for large batches.
6.3 User Mode Switch
Located on the back of the terminal, the functions of each mode switch position are as follows (I=ON, -=OFF, X=arbitrary):
S1 S2 S3 S4 operating mode
I X - Standard PLC mode (factory default)
I X I - No PLC standard mode
Transparent mode (with button start stop code)
Transparent mode (no button stop code)
I-I activation download (erase application memory)+default contrast
I-II activation upload
Operation, maintenance, and troubleshooting
7.1 General Information
The VCP type operation terminal is maintenance free, with only a few components being vulnerable parts that need to be replaced after running for a certain number of hours. Internal maintenance work of the equipment is only allowed to be performed by skilled personnel - please contact Bosch Rexroth service or ensure that only skilled personnel operate when hardware components need to be replaced. Before using new materials such as cleaning agents, compatibility testing of the casing material must be conducted (see Section 3.7).
7.2 Data Backup
Bosch Rexroth AG is not responsible for possible data loss and any resulting damages. Customers are required to backup their specific data themselves and provide that data during service.
7.3 Receipt Inspection
Carefully open the box and inspect the contents for any visible transportation damage, and verify if the goods match the specifications on the delivery note; If any transportation damage or discrepancy is found, the sales department should be contacted immediately.
7.4 Equipment Identification
Identify the device through the back nameplate, which includes the order name/short model code, part number, voltage and power specifications, and serial number. During device initialization, the screen will display information such as clock frequency, application memory size, current firmware version, programming software version, project name, time, date, compilation run times, and random numbers. Due to the initialization screen only displaying for a few seconds, the display can be extended: press and hold any key to generate an error message and read the firmware version, then release the key to complete the initialization.
7.5 Fuse
Semiconductor fuses are used to protect equipment and cannot be replaced. After the fuse is activated, the power supply must be disconnected for regeneration: regeneration takes about 20 seconds at an ambient temperature of 20 ° C, and the higher the ambient temperature, the longer the regeneration time.
7.6 Battery replacement and disposal
The built-in battery provides power for CMOS-RAM data retention and real-time clock operation. Even under unfavorable operating conditions, the minimum battery life is 5 years; Automatically generate a 'Change battery' message when the battery is depleted. It is recommended to replace the battery as a routine maintenance every 4 years, and finished batteries with pre installed connectors can be obtained directly from Bosch Rexroth.
If the 'Change battery' message is detected too late (such as real-time clock stoppage or date error), CMOS-RAM data may have been lost. Therefore, after replacing the battery, it is necessary to check modifiable data such as passwords, system variable parameters, recipe datasets, and message system entries.
Battery replacement can be carried out while the battery is charged to ensure that CMOS-RAM data and clock are not lost (safety instructions must be followed): unscrew the interface bolts → unscrew the backplate screws and remove the chassis → remove the cable fixing parts that fix the battery → disconnect the connector and remove the old battery → insert the new battery cable → fix the new battery to the chassis with cable fixing parts → reinstall the backplate → tighten the backplate screws and interface bolts in sequence.
Battery disposal: Used batteries must be returned to the recycling point established by the dealer or public waste disposal agency/certified battery dealer, and only put into public or commercial collection boxes. To prevent short circuits in the collection box, insulation tape should be used to wrap the poles of each battery or individual batteries should be placed in plastic bags. Batteries are hazardous materials that must be handled separately according to legal requirements (explosion risk, applicable to land, sea, and air transportation), and must not be mixed with ordinary garbage.
Order Information
VCP 08 model code composition (example VCP08.1BTN-RS-NN-FW):
Product line: VCP/08 series;
Structural design: 1;
Panel and display: BT=graphic display 120 × 32 pixels, 36 keys;
Additional options: N=None;
Interface: DN=DeviceNet, IB=INTERBUS, PB=PROFIBUS-DP, RS=Serial (RS232/485, TTY 20mA);
Additional design: NN=none;
Firmware: FW=firmware must be ordered as a separate item.
Accessories
Order code Material number Description
-1070917922 battery
IKB0053 R911305271 Download Cable
IKB0033 R911291808 PROFIBUS cable
IKB0051 R911350089 serial cable RS422
IKB0052 R911350090 Serial Cable RS232
The operating system of the device is a dedicated operating system, and if necessary, firmware can be re downloaded through the accompanying programming software "VI Composer". The debugging process is simple: after correctly installing the equipment, connect it to the power supply and control unit or bus system.