Product Overview: PC based Machine Tool Operation Panel
Rexroth Indramat BTV20.3 belongs to the System200 product family and is a PC based machine operator panel that can integrate one or more NC controllers with PLCs, or one or more independent PLCs - the number of modules that can be integrated depends on their configuration, and currently offers 8 slots. Its design objectives are divided into two types of application scenarios:
As a user, visualization, and programming terminal for independent machine tools with integrated control hardware;
As a user, visualization, and programming terminal connected to the RECOM controller.
Typical application areas include lathes, milling machines, and machining centers. BTV20.3 can only operate under specified assembly, installation, and environmental conditions (temperature, protection level, humidity, EMC requirements, etc.) and designated installation locations.
Differentiated features and standard configurations
The user oriented function keyboard of BTV20 has the following unique design:
4mm aluminum front panel with beveled edges;
Chemical resistant polyester facial mask with piercing and embossing;
Front protection level IP 65 (when the floppy drive cover is closed);
Integrated machine tool buttons, with intermediate ribs between the buttons to prevent double clicking or misoperation;
A key switch used to lock security functions.
The standard configuration includes: Pentium LOT-CPU (minimum 300 MHz, integrated graphics controller, 4 MB video memory and Ethernet connection), 64 or 128 MB working memory (optional), minimum 3 GB hard drive, 3.5 "floppy disk drive, 10.4" TFT color display, and 115-230 VAC or 24 VDC (optional) power supply.
Optional expansion modules: independent PLC module with INTERBUS-S or Profibus, PLC module with INTERBUS-S or Profibus, CNC module with SERCOS fiber interface, 10/100 Mbit Ethernet card PCM-E02.1. The configuration type code lists all available configurations.
Firmware and software: Due to licensing reasons, BTV20.3 is only delivered with the pre installed operating system; In addition, the user interface of MTC200 CNC controller or ISP200 PLC controller can be pre installed. Multiple firmware configurations are available under Windows NT (FWA-BTV203-WnT series), defined as GUI (graphical user interface), PO * (programming interface), HMI (human-machine interface - production machine tool user interface). Note: The FWA firmware order only includes the installation of the listed software, and the SWA/SWL software products to be installed must be ordered separately - SWA is a software package that includes floppy disks/CDs and instructions, and SWL is a software license that allows existing software packages to be reused.
Definition of correct and incorrect use
Rexroth Indramat products are developed and manufactured at the forefront of the industry, and undergo safety and reliability testing before delivery. The product can only be used in the manner defined as' appropriate use '; The manufacturer shall not be held responsible for damages caused by improper use, and the warranty and claim rights shall be lost simultaneously. The prerequisites for use include: the operator must first read and understand the relevant safety instructions; Hardware must not undergo structural changes, nor decompile software or modify source code; Do not install or use damaged or faulty products; Installation must be carried out in accordance with the document specifications.
Prohibited use scenarios: underwater operation, extreme temperature fluctuations or ultra-high temperature environments, and use without explicit authorization from Rexroth Indramat. The prohibited use areas explicitly listed in the general safety instructions include: construction cranes, passenger and cargo elevators, personnel transportation equipment, medical applications, refineries, dangerous goods transportation, radioactive or nuclear applications, high-frequency sensitive applications, mining, food processing, protective equipment control, etc.
Key points of safety instructions (servo drive and control)
Safety warnings are classified according to ANSI: DANGER (inevitable personal injury or product damage), Warning (possible death or serious personal injury), CAUTION (possible death or serious personal injury). Core risks and countermeasures:
Electrical safety: When it comes to voltages above 50 V, only trained and qualified electrical personnel are allowed to operate and maintain it; Before powering on, the protective grounding wire must be permanently connected to all electrical units according to the wiring diagram; If the leakage current exceeds 3.5 mA, the equipment must always be firmly connected to the power supply network, and protective connections must use copper conductors with a cross-sectional area of at least 10 mm ² throughout the entire process; After power failure, wait for 5 minutes to discharge the capacitor and measure the voltage; It is strictly prohibited to use residual current protection devices (r.c.d.) for electric drives, and other methods such as overcurrent protection must be used for indirect contact protection.
Dangerous motion protection: Incorrect wiring, misoperation, sensor/encoder failure, component defects, or software errors can all cause dangerous motion - it can occur immediately after power on or after a period of trouble free operation. Upper level monitoring or measures must be set up above the device; The emergency stop switch must be installed within easy reach of the operator and verified before starting; Isolate the driving power supply through emergency stop circuit or start suppression system; After the vertical axis is powered off, it is necessary to prevent falling - mechanical locking, external brake/clamping mechanism, or counterweight balance can all be used, but standard motor brake or servo driven direct control external brake are not sufficient to ensure personnel safety.
Other protections: wearers of pacemakers, metal implants, and hearing aids are not allowed to enter the storage, operation, and maintenance areas of motor permanent magnets; Wait for 10 minutes for cooling before touching high-temperature components; Batteries are strictly prohibited from being heated, reactivated, charged, ignited, or disassembled. As hazardous materials, they must be disposed of separately according to legal requirements (explosion risk, applicable to land, sea, and air transportation); The pressurized system (compressed air, hydraulic oil, coolant) must be depressurized and drained before disassembly.

Front panel and keyboard system
Soft drive cover and reset button: A reset button (accessible with a fine object such as a ballpoint pen) and an external keyboard connector are located below the soft drive cover. When there is no PCK03 external keyboard, this connector can be used as a service interface. Pressing the reset button will terminate all open applications without saving and restart the computer. During the operation of the floppy drive, the cover plate must be kept open. Closing the cover plate may cause read and write errors.
Status display: There are three LEDs under the cover plate: TEMP (temperature monitoring), POWER (always on when powered on), and HDD (lights up when accessing the hard drive).
Button system:
Function keys (F2-F9) and operation keys (OP2-OP9): The second function of the dual function key needs to be activated by pressing the "up arrow" (Shift) key simultaneously; The OP key line can also be configured with an insert tab bar;
PC keyboard simulation: OP2 → OP9 corresponds to CTRL+SHIFT+ALT+F2 → F9, PROG corresponds to CTRL+SHIFT+ALT+Q, NEXT corresponds to CTRL+SHIFT+ALT+N, INFO corresponds to CTRL+SHIFT+ALT+I, Menu corresponds to ALT, Change windows corresponds to CTRL+F6, Grass window corresponds to CTRL+F7, Maximize in cursor center corresponds to CTRL+SHIFT+ALT+M;
Machine function keys (L1-L8 on the left, R1-R8 on the right): used as direct hard wired inputs in PLC, addressing by absolute address (L1=% I0.1480.0 to L8=% I0.1480.7, R1=% I0.1481.0 to R8=% I0.1481.7), used to start configured PLC or CNC movements; It can also be addressed with address constants MFT-L (A # iMFK-L) and MFT-R (A # iMFK-R). PLC program example: MFT.L.L1;
PLC function keys (S1-S14, with LED) and key switch (Operator/Prog): illuminated pluggable label keys, connected to the PLC together with the key switch, replacing standard switch components that fix PLC functions (such as "return to reference point" or "end of cycle shutdown"); Key addresses% I *. 0.0 to% I *. 1.7, LED addresses% Q *. 0.0 to% Q *. 1.7, two free logical addresses must be allocated in the PLC configuration.
Insert label replacement: 14 PLC function keys and OP key rows can be replaced. Insert labels - cut by line, pinch the right end and slide it in. The labels must be inserted into the foil bag attached to the front panel (otherwise only the first baffle can be inserted). After sliding to the bottom, check the fit between the button and the label. If it is not suitable, cut it short and reinsert it from the right side. The remaining part can be cut but the possibility of replacement must be retained.
Keyboard language: Adjust the external keyboard in the Windows NT control panel (Keyboard → Input localities); The built-in embossed keyboard needs to be set through the "BTV20" icon on the control panel (in American English/German/British English/Italian/Spanish). If the icon does not exist, the SWD-BTV20 * - UTI-01VRS tool disk needs to be installed. The selected language must be consistent with the external keyboard settings in the operating system.
Quick Overview of Technical Data
Project specifications
Processor Pentium Slot CPU with a minimum frequency of 300 MHz, integrated graphics controller
Main memory/hard disk 64 MB/minimum 3 GB
Interface 1: Serial RS232, 1: Parallel Centronics, 1: Indramat RS232/422/485
Display 10.4 "TFT color
Slot 3 x PCI, 1 x PCI/ISA, 4 x ISA
Keyboard machine operation keyboard, 16 machine function keys
Protection front IP65, chassis IP20 (DIN 40 050, IEC 529)
Panel color RAL 7035 light gray
Dimensions (rear shell/including panel) 372 × 335 × 209/407 × 370 × 220 mm (B × H × T)
Power supply 115/230 VAC ± 15% automatic switching, maximum 250 VA
Typical heat dissipation of 100 W/maximum of 200 W
Weight approximately 10.5 kg
Power supply unit: Input range 90... 132/180... 264 VAC, 47... 63 Hz; Input current 4.2 A @ 115 V/2.0 A @ 230 V; Surge current 35/70 A; output+5 V (5... 20 A,+5%/-4%), -5 V,+12 V (2... 8 A), -12 V; Maximum output of 200 W, efficiency of 70% @ 230 V/200 W; Working temperature: 0... 45 ° C @ 200 W/0... 55 ° C @ 100 W.
Environmental conditions: Operating temperature+5 ° C to+45 ° C (storage/transportation -20 ° C to+60 ° C); Temperature change rate 10 K/h (15 K/h); Relative humidity of 75% average/80% occasional (storage without condensation, DIN 40 040 F level); Air pressure 860-1060 hPa to 1500 m; maximum external magnetic field 6 × 10 ⁻⁴ Tesla; Vibration (without FDD access) 5-55 Hz ± 0.0375 mm sine three-axis, 55-500 Hz 0.5g; Impact 15g/11ms half sine (storing 30g).
Vulnerable parts (not covered by warranty): fan, backlight tube, floppy disk drive, hard disk, Slot CPU battery. The average life expectancy is 5 years or 20000 operating hours. The HDD lifespan specifications are based on: 40 read/write cycles/day x 200 days/year, 10 ⁵ seek cycles/day x 200 days/year, 14 h/day power supply, 8 h/day read/write, and no vibration or impact in an environment of 25 ° C/50% RH/100kPa.
Size and Installation
The panel opening size is 373 × 336 mm; the installation adopts a front installation method: 10 × sealed M5 × 16 bolts pass through the panel, and are fixed to the installation panel with 10 × M5 combination nuts, locking washers, and flat sealing rings. At least 20 mm gap must be left between the rear and sides for air circulation; The connector space requirement is about 100mm.
Detailed explanation of connections and interfaces
Power supply and grounding: 115/230 VAC ± 15% automatic switching, P–250 VA,50/60 Hz; Connect the minimum 6 mm ² grounding terminal to the central grounding terminal.
Slot CPU interface: serial port COM1(Pin1 DCD、2 RxD、3 TxD、4 DTR、5 GND、6 DSR、7 RTS、8 CTS、9 N.C.)——CPU The board is driven by a capacitive charge pump RS232 and only powered by 5V; Due to COM1's RS232/RS422/RS485 multifunctional capability, RI (ring indicator) signal is not supported and is used as output in RS232 mode. Do not connect any signal. SVGA screen connection and Ethernet 10Base-T (Pin1 TxD+, 2 TxD -, 3 RxD+, 6 RxD -) are complete.
LPT1 and SIS: The two interfaces are directly connected to Slot CPU via printed circuit board PSU02; COM2 (X16) is wired according to Indramat standard (SIS) and supports RS485/RS232/RS422; LPT1 has standard Centronics pins. The GPIO configuration of PSU02 is determined by BIOS settings (Inside Utilities), and the output level combination of General Purpose IO 1/4/6 determines the RS485 (Auto/Input/RTS-Control//RTS Control) and RS422 (Off/Auto/Output/Input/RTS-Control) functions - the factory default is the Output (high) x 3 combination.
BIB05 card insertion (PC version): The PC variant (with the 4th digit of the function type code being "P") only includes a CPU module and no controller. Equipped with a BIB05 card, the machine's function keys and key switches can be accessed via Interbus and ISA buses. BIB05 is a short 8-bit PC card: 8 consecutive I/O addresses are allocated on the ISA bus (configurable base addresses 0000h-03C0h), and the rotary encoding switch selects the base address (factory base address 140h is the 'A' bit); The two bus systems can independently read all keys simultaneously, but only one bus system can write the S1-S14 keys and key switch LED. The three position sliding switch selects write access (1-way circuit=ISA, middle=disabled, 2-way slot board=Interbus), and the factory configuration is "Interbus write access"; ID-COde 03h (digital device with input/output data), with a data width of 2 words. ISA address mapping: Base+0=S8... S1, Base+1='Prog' key switch/'Operator' key switch/S14... S9, Base+2=R8... R1, Base+3=L8... L1, Base+4/5=LED - buttons L1-L8, R1-R8, S1-S14 and the key switch are indicated by '1' for corresponding contact closure. Interbus side PLC function key address% I *. 4.0-% I *. 5.7, machine function keys L1-L8=% I *. 7.0-. 7, R1-R8=% I *. 6.0-. 7.
INTERBUS connection (X65 out/X66 in): X65 includes DO/DI, GND,+5V, RBST (9-pin); X66 is for DO1/DI1 data entry and exit.

Application examples
MTS-P+INTERBUS: The MTS-P X60 of BTV20 is connected to RECOM12 (RMK12.1-IBS-BKL module) via IKS 0056 INTERBUS-S cable, with Remote Bus Interconnect supporting more INTERBUS-S devices, supplying power from 3 × 0.75 mm ² to+24 VDC;
BTA10/20 and BTC06: MTS-P0x. 2 (marked as 2D in the configuration code) and Fast PLC (marked as 2F) have integrated a 15 pin Indramat standard interface in their slots, connected to BTA20 via IKB0015 cable; Up to 6 BTA10s can be operated, and only one BTC06 can be operated at a time. The key switch activates the interface on the BTA module; Only RS422 communication is available between units (IKB0015 has a maximum RS422 length of 400 meters);
SIO extension: By configuring code S4 (such as CFG BTV20.3E-NN-2T-NN-BB-S4-B1-2D-2E-NN), two additional interface slots can be connected to BTA10 through SIO on the printed circuit board using IKB0016;
MTC-P+SERCOS: The BTV20 integrated with NC card is connected to the DIAX04 driver amplifier (HVE/HVR power supply module, with a maximum of 8 driver modules per SERCOS fiber) via fiber optic cables IKO0985/IKO0982, achieving 8-axis control.
Standard interface connectors: INS0619/K01 (RS485, 15 pin, Y-shaped customer connection with termination, containing 390 Ω/150 Ω/390 Ω termination resistors) and INS0645/K01 (RS422, 15 pin, customizable with termination) can be terminated through corresponding switches.
SLOT-CPU card and AMIBIOS
The CPU board is 686LCD/MG: 64 bit onboard video controller with 4 MB of video memory, dual support for tablet and standard VGA, RS232C+RS422/485, Centronics/ECP/EPP parallel ports, EIDE hard disk interface and floppy disk controller, PCI Ethernet 10BASE-T RJ45, USB. Power supply+5/+12 V (± 3%, can operate only+5 V), power consumption 10-20 W, backup battery CR2032 lithium battery+3.0 V; AMD K6 III minimum 300 MHz (300-400 MHz), INTEL 430HX core chipset, maximum 512 MB DRAM (EDO or Fast Page); 0-60 ° C forced cooling, 10-90% non condensing humidity; Watchdog circuit monitors power supply and program execution; The Secure CMOS option backs up CMOS memory within Flash BIOS and automatically reloads when lost.
AMIBIOS Setup: Press Enter in the startup sequence; Four window main menu (Setup/Utilities/Security/Default); Two default values - Optimal and Fail Safe (the most basic parameters used for diagnosing system abnormalities and automatically loading when CMOS is lost). Password support: Supervisor/User dual level password, 1-6 characters, encrypted and stored in CMOS; Forgot password requires clearing CMOS (press Del or remove battery for 5 minutes when turning on). Beep code diagnosis: 1/2/3 beeps=reinsert SIMM memory (replace memory if still ringing), 6 beeps=replace keyboard or keyboard fuse, 8 beeps=graphics card or video memory error, 9 beeps=BIOS ROM chip damaged and needs to be replaced, 11 beeps=reinsert cache on board (replace if still ringing), 4/5/7/10 beeps=fatal error. SIMM installation: Insert into the slot at a 45 ° angle and carefully pull it into place vertically.
Ethernet card PCM-E02.1
Can connect BTV20 to 10 Mbit/s Ethernet or 100 Mbit/s Fast Ethernet; RJ-45 port automatically matches hub/switch speed; AUI and BNC ports only support 10 Mbit/s. The BNC port is connected to a 50 ohm coaxial network through a T-shaped adapter, and the terminal equipment must be connected to a 50 ohm terminal resistor in the idle branch. Three LEDs: 10 LNK (green, connection OK; flashing=opposite polarity), 100 LNK (green, no flashing when well connected at 100 Mbit/s), ACT (yellow, data flow). Technical data: 4 KB internal RAM, PCI 32-bit bus, PCI Master DMA,+12 V ± 5% maximum 390 mA/+5 V maximum 520 mA, operating at 0-70 ° C; Compliant with IEEE 803.3x flow control Microsoft PC98、PCI 2.1、DMI 1.0/2.0。
Smart Card connector (optional)
Model code 10th digit: D=3.5 "/1.44 MB floppy drive, S=Smart Card interface. Electrical characteristics (IEC 60512 series testing): data contact ≤ 100 m Ω, switch contact ≤ 200 m Ω, insulation resistance ≥ 10 ⁹ Ω, withstand voltage of 500 VAC for 1 minute; Climate category 25/85/21, operating/storage temperature -25 ° C to+85 ° C; card insertion force 3-5 N, contact force 20-50 cN. Only ID-1 chip cards with chip center position (ISO 7810 size, ISO 7816 contact position) are allowed to be used. The insertion and removal process adopts a ballpoint pen style pressing principle: insert until it is touched, it will snap into place, press it again to eject and be ejected by the spring to retrieve the card. The installation frame contains card readers and chip card electronic components, which are connected to X101 via a 10 core flat cable. Add external service floppy drive connection slot board (9-pin D-SUB, connected to Slot CPU COM1 via serial cable IKB0028) to UE1 slot during delivery.
Order Information
Type code (such as BTV20.3CA-64B-33C-D-FW): Product group BTV/Series 20/Design 3/Function type (A=MTA, C=MTC both require export license, P=PC, S=ISP)/Keyboard standard A/Memory 28=128 MB, 64=64 MB/16 machine function keys double-sided B/System configuration 33=Minimum 3 GB, Minimum 300 MHz, RS485 (SIS)/Voltage C=AC 115-230 V 50-60 Hz/Disk D=floppy drive, S=Smart Card/FW=Firmware must be ordered as a separate sub item.
There are three types of configuration codes:
BTV20.3C (MTC): Example CFG BTV20.3C-NN-2T-NN-BB-S4-B1-2D-2C-NN. Slot rule: U1 always installs PC module; U3 – U6 (PCI) The first Ethernet card "2T" is only limited to U3, the second is only limited to U4; U6 – U10 (ISA) is arranged in the order in the table; ISA/PCI bus components start with numbers (such as 2C), while PC104 bus starts with letters (such as B1);
BTV20.3S (ISP): Example CFG BTV20.3S-NN-2T-NN-BB-S4-P1-B1-2D-NN;
BTV20.3A (MTA): Example CFG BTV20.3A-1F-NN-B1-2F-3L-2L-1L-1N-1V. Slot rule: U2 constant installation link interface module MFA "1F"; The serial port module BB-S4 occupies two slots; MTS-P "2D/2F" is only suitable for U6 or U5 (MTS-P can be equipped with up to three or two PC104 modules when there are multiple SERCOS modules); The third SERCOS "3L" is only available for U6; U8-U10 are always equipped with 1L/1N/1V (SERCOS, NC-CPU, multi I/O MIO).
Accessories: IKB0193 (RS232 up to 2 m), IKS0056 (Interbus cable), IKS0190 (BTC06 connection), IKB0015 (RS422 up to 400 m), IKB0016 (RS422 up to 400 m), IKB0028 (RS232 0.20 m), matched with INS0525/L01, INS0526/L01, INS0624/C, INS0631/C, INS0456/L01, INS0457/L01 connectors and INK0234 cable; Lockable floppy drive cover kit SUP-M01-BTV20.
Random delivery list: Installation kit (10 × M5 × 12 flat head bolts, 10 × M5 Nyltite washers, 1 × three core cable socket for 230 V models only, 404 × 4 × 0.8 and 365 × 4 × 0.8 mm panel sealing rings); Identification kit (printing insertion label recommendation+SWD-HMIBT-STP-01VRS-MS-C1,44 label template plate); SWD-BTV20-UTI-01VRS-MS-C1, 44 keyboard language setting software disk; Ordered firmware and software packages.