DeltaV ™ Flex Connect Solutions for Foxboro ™ I/A Series 100 I/O

来源: | 作者:FAN | 发布时间 :2025-09-11 | 714 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

DeltaV ™  Flex Connect Solutions for Foxboro ™  I/A Series 100 I/O

Core positioning and value

The FlexConnect solution is a modular and scalable connection solution for Foxboro I/A Series 100 I/O systems. Its core value lies in breaking the limitations of traditional I/O systems' fixed cabinet installation. Through remote/distributed connection capabilities, flexible topology configuration, and high reliability design, it adapts to the complex installation environment and diverse equipment access requirements of industrial sites (such as chemical, petroleum, power, etc.), simplifies wiring, reduces installation costs, and improves the overall maintainability and fault resistance of the system.


System architecture and core components

The FlexConnect solution adopts a layered architecture of "main controller remote I/O unit field device", with core components including remote I/O modules, communication links, terminal components, and supporting accessories. The functions and collaborative relationships of each part are as follows:

(1) Core components and functions

Component type, key model/specification, core function

The remote I/O module supports Foxboro I/A Series 100 I/O signal types (such as analog input/output, digital input/output, HART communication, etc.) 1. Local acquisition/output of field device signals (such as 4-20mA, discrete signals);

2. Implement signal isolation and anti-interference processing;

3. Bidirectional transmission of data with the main controller through a communication link.

The communication link supports redundant/non redundant Ethernet and dedicated industrial bus to ensure high-speed and stable data transmission between the main controller and remote I/O modules;

2. Redundant link design avoids communication interruptions caused by single point failures.

Terminal Assembly (TA) is a specialized terminal module that adapts to different signal types. 1. It provides physical wiring interfaces between field devices and remote I/O modules;

2. Support cable fixation and anti loosening design, suitable for different wire diameters (such as 0.2-4mm ² wires).

Power module 24V DC redundant power supply 1. Provides stable power supply for remote I/O modules and terminal components;

2. Redundant design ensures seamless switching in case of power interruption, ensuring the continuous operation of the module.

The protective casing meets the IP rating (such as IP65/IP67). 1. It protects remote I/O modules and terminal components from on-site dust, water vapor, and corrosive gases;

2. Suitable for installation in outdoor or harsh industrial environments.

(2) Topology configuration flexibility

Distributed deployment: Remote I/O units can be installed near field devices (such as equipment side or field cabinets), significantly reducing the length of cables from field devices to I/O modules (traditional solutions require cables to be pulled to the central cabinet, while FlexConnect can reduce wiring by more than 50%).

Multiple topology support: Supports various communication topologies such as star, bus, and ring, and can be flexibly selected according to the distribution density and distance of on-site devices (such as ring topology is suitable for long-distance and multi node scenarios, improving communication redundancy).

Mixed signal access: A single remote I/O unit can simultaneously access multiple types of signals such as analog, digital, and HART, without the need for separate cabinets for different signals, simplifying the system architecture.

Core functions and technical features

(1) High reliability and fault redundancy

Communication redundancy: Supports dual Ethernet links or redundant industrial buses. In the event of a main link failure, the backup link can automatically switch within milliseconds (<100ms) without data loss, ensuring process control continuity.

Power redundancy: The remote I/O unit adopts dual 24V DC power input. When a single power supply fails, the other power supply seamlessly takes over to avoid signal interruption caused by module power failure.

Module level isolation:

Galvanic isolation is implemented between each I/O channel and between channels and module logic circuits (with an isolation voltage of up to 600V AC/1 minute) to prevent module damage caused by on-site signal interference or grounding loops.

The analog channel supports independent current limitation (such as a maximum of 25mA) to avoid the impact of load short circuits on the module.

Fault diagnosis and alarm:

The module has built-in real-time diagnostic function, which can monitor channel faults, communication abnormalities, power supply voltage fluctuations and other issues, and upload alarm information to the main controller through the communication link.

Support local LED indicator light alarms (such as normal power supply, communication status, channel failure), making it easy for on-site maintenance personnel to quickly locate problems.

(2) HART communication compatibility and support for smart devices

HART protocol integration: All analog I/O modules support the HART protocol (compatible with HART 5/6/7 versions) and can overlay digital communication on 4-20mA analog signals to achieve:

Remote reading of diagnostic information, range settings, and calibration data from smart devices such as HART transmitters;

Remote configuration and calibration of on-site HART devices through the main controller, without the need for on-site operation.

HART data processing: Supports HART universal instructions, conventional operation instructions, and device specific instructions. The main controller can receive multiple digital messages from each HART device per second, meeting real-time monitoring and control requirements.

(3) Installation and maintenance convenience

Modular design:

The remote I/O module and terminal components adopt a modular structure and support "hot plugging" (some models). When replacing the module, there is no need to disconnect the on-site wiring or interrupt the system operation, reducing maintenance downtime.

The module size is compact (such as height ≤ 150mm, width ≤ 30mm), and can be installed on DIN rails or small cabinets, suitable for on-site environments with limited space.

Simplified wiring:

Remote deployment reduces the long-distance wiring of on-site equipment to the central cabinet, lowering cable costs and construction difficulties;

The terminal component supports the "one in, multiple out" wiring method, which can simultaneously connect multiple on-site devices of the same type, simplifying the wiring logic.

Configuration tool support:

Compatible with Foxboro I/A Series system configuration software (such as FoxDraw, Control Builder), remote I/O module channel parameters (such as range, alarm threshold, fault safety action) can be configured remotely through the software without on-site debugging.

(4) Environmental adaptability

Protection level: When the remote I/O unit is paired with a dedicated protective casing, the protection level can reach IP65/IP67, and it can be directly installed outdoors or in dusty, humid, and corrosive environments (such as chemical workshops and refinery sites).

Temperature and humidity range:

Working temperature: -20 ° C to+60 ° C (some models support a wide temperature range of -40 ° C to+70 ° C);

Working humidity: 5% -95% (non condensing), suitable for high humidity industrial environments;

Anti vibration performance: Within the frequency range of 5-500Hz, it operates stably under a vibration intensity of 7.5m/S ² (0.75g), meeting the requirements of industrial site vibration environment.

Detailed explanation of technical specifications

(1) Electrical and Communication Specifications

Specification category parameter details

Power requirement input voltage: 24V DC (allowable fluctuation range:+5%/-10%);

Maximum power consumption: Single module ≤ 8W, redundant configuration ≤ 16W.

Communication rate Ethernet link: 10/100Mbps adaptive;

Industrial bus: Depending on the bus type, it can reach 1Mbps (such as Profibus DP).

Signal type supports analog input (AI): 4-20mA, 1-5V;

Analog output (AO): 4-20mA;

Digital input (DI): dry contact, 24V DC wet contact;

Digital Output (DO): Relay output, 24V DC transistor output.

HART performance baud rate: 1200bps (half duplex);

Support message types: general instructions, general operation instructions, device specific instructions;

Data verification: 32-bit CRC verification to ensure communication accuracy.

Isolation performance between channels: 600V AC/1 minute;

Channel and ground isolation: 600V AC/1 minute;

Power and logic isolation: 500V AC/1 minute.

(2) Environmental and mechanical specifications

Specification category parameter details

Working temperature standard type: -20 ° C to+60 ° C;

Wide temperature range: -40 ° C to+70 ° C.

Storage temperature -40 ° C to+85 ° C (non condensing).

Working humidity 5% -95% RH (without condensation, temperature ≤ 40 ° C).

Protection level module bare machine: IP20 (to be installed in the cabinet);

Equipped with protective casing: IP65/IP67 (can be installed outdoors).

Installation method: DIN rail installation (compatible with 35mm standard rail);

Fixed installation of cabinet screws.

Module size (example) height: 130mm (5.12 inches);

Width: 25mm (0.98 inches);

Depth: 150mm (5.9 inches);

Weight: Approximately 200g (7.05 ounces).

(3) Compliance certification

Electromagnetic compatibility (EMC): Complies with the EU EMC Directive (2014/30/EU), meets the Class A emission requirements and industrial immunity levels (anti-static, radio frequency interference, electrical fast transient pulse group, etc.) of EN 61326-1:2013 standard.

Security certification:

UL/UL-C certification: suitable for hazardous environments with Class I A-D groups, Zone 2, T4 temperature codes (with designated Foxboro I/A Series controllers);

ATEX certification: Ex nA IIC T4 Ga, suitable for Zone 2 hazardous environments;

IECEx certification: Compliant with IEC 60079-15 standard, suitable for global hazardous area applications.

Environmental compliance: Compliant with the EU RoHS Directive (2011/65/EU), restricting the use of harmful substances such as lead, mercury, cadmium, etc;

Marine certification: Some models have been certified by American Bureau of Shipping (ABS) and Bureau Veritas, and are suitable for marine environments such as ship power systems and offshore platforms.


Application scenarios and supporting documents

(1) Typical application scenarios

The FlexConnect solution is mainly suitable for industrial process automation scenarios of Foxboro I/A Series 100 I/O systems, especially for the following needs:

In scenarios where on-site equipment is dispersed, such as large chemical parks and refineries, where equipment is distributed over a wide area, remote I/O deployment can reduce long-distance wiring costs;

Adverse environmental scenarios: such as outdoor storage tank areas, high temperature/high humidity workshops, modules with IP65/IP67 protective enclosures can be directly installed without the need for additional protective cabinets;

High reliability requirements scenarios: such as power systems, oil platforms, redundant communication and power supply design to ensure uninterrupted process control;

Intelligent device intensive scenarios: such as process industries equipped with a large number of HART transmitters, the solution can efficiently integrate HART digital communication to achieve remote management of intelligent devices.

(2) Key reference documents

Document Number Document Name Core Content

PSS EN 67866 FlexConnect Solutions Product Data Sheet Overview, Core Component Specifications, Technical Parameters, Certification Information;

Foxboro I/A Series 100 I/O User Guide Foxboro I/A Series 100 I/O User Guide 100 I/O System Basic Operations, Module Configuration Methods, Fault Diagnosis Process;

FlexConnect Installation Manual: Installation steps, wiring specifications, and debugging guidelines for remote I/O modules, terminal components, and protective enclosures;

HART Communication Guide for Foxboro I/A Series Foxboro I/A Series HART Communication Guide: Steps for HART Device Access Configuration, Data Reading, and Remote Calibration Operations.


Core differences from traditional I/O solutions

Comparison Dimension FlexConnect Solution Traditional Foxboro I/A Series 100 I/O Solution

Deployment method: remote/distributed deployment, centralized deployment near on-site equipment, all cables need to be pulled to the central cabinet

Reduce wiring costs by more than 50%, reduce cable and construction costs for long-distance wiring, which is costly and complex to construct

The maintenance efficiency module supports hot plugging, local LED alarms, and quick fault location. It requires opening the central cabinet for maintenance, and fault diagnosis relies on controller data

Environmental adaptability supports IP65/IP67 protection and is suitable for harsh/outdoor environments. It relies on central cabinet protection and cannot be directly exposed to harsh environments

Redundancy capability: Communication and power dual redundancy, with millisecond level fault switching. Only some core modules support redundancy, and communication redundancy requires additional configuration

  • ABB SCC-C 23070-0-10232110 gas cooler
  • Sick LGTN101-521 CPU Module
  • Okuma 1911-2836 PLC Circuit Board
  • Mitsubishi Melsec PM-120M PLC
  • Omron F210-C15 Vision Mate Controller System
  • Siemens 7ML5110-1GD07-4AF3 Ultrasonic Level Gauge
  • ABB Pluto S46 V2 Safety Relay
  • Omron Z3RN-5A Optical Serial Link
  • Omron R7D-APA3H 30W Servo Drive
  • Giddings Lewis 502-03638-41R3 PLC Processor
  • Omron SCY-P1 Sequencer Controller
  • Siemens C98043-A7002-L1-13 PCB Board
  • SACS TECNICA Palletizer PC PLC Control System
  • AutomationDirect T1F-14THM PLC Module T1F14THM
  • OMRON C200H-AD003 Analog Input Unit PLC Module
  • Applied Materials 0010-A0000 Electricity Box PLC 200mm
  • ABB RVT-6 Power Factor Controller RVT6
  • Allen-Bradley 2094-BC01-MP5-M Kinetix 6000 Axis Module
  • OMRON FQM1S-MC233 Motion Controller PLC Module
  • OMRON C200H-SNT31 PLC Special I-O Module
  • Yaskawa SGMPH-04AAA61D-OY Servo Motor 400W 200V
  • Yaskawa SGMGH-09DCA6F-OY AC Servo Motor 850W 400V
  • REFU ELEKTRONIK SR17002 PLC Logic Module Circuit Board
  • Siemens 6DP1231-7AA PLC Board Module Industrial Control
  • ABB SACE ISOMAX S3 N 160 Molded Case Circuit Breaker
  • OMRON C120-SC024-V1 SYSMAC C120 Compact PLC Unit
  • OMRON CJ1W-SCU41-V1 Serial Communication Unit PLC Module
  • OMRON 3G3MX2-A4110-ZV1 MX2 Variable Frequency Drive
  • Yaskawa SGDH-04AE-OY Sigma-II Servo Driver 400W 200V
  • OMRON CQM1-AD041 Analog Input Module PLC I/O Unit
  • Delta Omega XML2-0060-45-4/S-A Servo Drive
  • Omron CJ1W-AD041 Analog Input
  • Omron CJ1W-NC271 Position Control Unit
  • Omron CJ1G-CPU45H PLC CPU
  • Omron CJ1W-EIP21 EtherNet/IP Unit
  • Omron F210-C15 Vision Mate Controller
  • Omron CQM1H-ADB21 Analog I/O Board
  • Omron GRT1-PRT PROFIBUS DP-V1 Adapter
  • Omron CP1H-Y20DT-D PLC CPU
  • TE.CO TFX 4G 1.5 Grey Cable 470m
  • Yaskawa SGDH-04AE-OY Servo Driver 400W 200V
  • OMRON CJ1H-CPU66H V4.0 PLC CPU
  • OMRON R7M-A10030-BS1 Servo Motor 200W 100V
  • OMRON FQM1-MMA21 Motion Controller
  • Yaskawa SJDE-08APA Servo Amplifier
  • OMRON CQM1-AD041 Analog Input Unit
  • Siemens OCI55 Dialogue Module Landis
  • OMRON F350-C10E Image Processing Unit
  • OMRON NT10S-SF121 HMI Terminal
  • SIEMENS 3RB1262-0LB31 Overload Relay
  • OMRON YASKAWA SGDS-02A12A Servo Drive
  • TE.CO TFX 4G 1.5 Grey Cable ST 500m
  • FANUC A16B-3200-0362 PCB Control Board
  • OMRON CQM1-ARM21 Analog Output Unit
  • Allen-Bradley 1788-EN2DN Ethernet DeviceNet Gateway
  • Siemens 3VL9440-7EE40 3VL4740-2AA46-0AA0 Circuit Breaker
  • OMRON CJ1W-AD041-V1 Analog Input Unit
  • OMRON CQM1-AD041 CQM1-IPS02 Analog Input Power Supply
  • Texas Instruments System 505 PLC 525-110 525-1102
  • OMRON CQM1-AD042 Analog Input Unit
  • Yaskawa SGDH-04AE-OY Servo Driver 200V 400W
  • CTI 2512 75W Power Supply for CTI 2500
  • Omron F300-B5 Image Processing Unit
  • Mitsubishi 15050-PR01A PLC Board
  • Omron CQM1-TC101 Temperature Controller
  • SCE M68-2000 2 Axis Motion Controller HW 2.3/B
  • Omron 3Z4SP-C22 Visual Positioning Sensor
  • Omron 3G3SV-BB007-E 0.75kW VFD
  • CML 6622 IRD Entek AW10528 Vibration Monitor
  • Omron CP1L-EL20DR-D PLC CPU
  • TE.CO TFX 4G 1.5 Grey Cable 500m
  • Mitsubishi Electric 3BK23057 Circuit Board Module
  • OMRON FQM1-MMP21 Motion Control Module
  • OMRON CP1E-E40SDR-A Micro PLC CPU Unit
  • KEBA CU201 PLC Control Unit
  • OMRON F150-C10E-2 Vision Sensor Controller
  • YASKAWA SGDH-04AE-OY Sigma-II Servo Driver
  • OMRON CS1H-CPU65-V1 PLC Central Processing Unit
  • OMRON NB7W-TX01B Interactive Display HMI
  • OMRON C500-TU002E Programmable Logic Controller Timer Unit
  • OMRON C200HW-PRT21 PROFIBUS DP Slave Unit
  • ExcelTech MX-5-S-I-6-4 Static Transfer Switch
  • Allen-Bradley 100-B300ND3 Contactor 304A 600V
  • Pasaban MTC-3052 Fast I/O PLC Card
  • OMRON CQM1-TC101 Temperature Control Unit
  • OMRON 3G3SV-BB007-E VFD 0.75kW 220V
  • OMRON CQM1H-MAB42 PLC Module
  • OMRON R88M-K75030T-S2 Servo Motor
  • Yaskawa SGMAH-03DAAA61 Servo Motor 200V 300W
  • OMRON F300-P Power Supply Unit
  • Land System 4 M1 Thermometer 65071800C-L35-A50
  • Yamatake MAH10-ME0100 ME-NET Module
  • Siemens Simatic 505 16 Slot PLC Rack
  • Yaskawa SGDH-02AE-OY Servo Driver 200W
  • SCE M68-2000 2-Axis Motion Controller
  • Zenith Controls K-1201 Transfer Switch Controller
  • Yaskawa SGDH-02AE-OY 200W Servo Driver
  • Yaskawa SGMAH-02AAA61D-0Y 200W Servo Motor
  • Schneider TSX P573634M Modicon Premium CPU
  • Siemens 6FX5002-5DN31-1DA0 Power Cable
  • Omron CJ1G-CPU43H CPU Unit 30K Steps
  • OMRON C28P-EDR-D PLC Unit
  • SIEMENS S7-300 PLC System
  • Schneider TP400-PLC-1411 Board
  • Siemens 6FC5203-0AF00-0AA3 Panel
  • ALLEN BRADLEY 1754-L28BBB GuardPLC
  • Omron E6C3-AG5B-C Encoder
  • SCE M68-2000/5 CNC Controller
  • SCHNEIDER TM2ALM3LT Module
  • OMRON C200H-OV001 Voice Module
  • OMRON R88M-H30030 Servo Motor
  • Bosch RD500 Indramat Servo Drive RD51.2-4B
  • Siemens 6SE7090-0XX84-0AH2 T300 Module
  • Omron GRT1-TS2P SmartSlice Thermocouple Input
  • Xaar XP55500016 XUSB Drive Electronics
  • Siemens 6SL3210-1SE21-8UA0 PM340 Power Module
  • Mitsubishi GT2708-VTBA Touch Display 8.4 Inch
  • Pasaban Fast I/O MTC-3052 PLC Card
  • ABB ACS355-01U-02A4-2 VFD 0.37kW
  • Yamatake MAH20-PC2100 Processor Module
  • Allen Bradley 1774-P1 PLC Power Supply
  • Yaskawa SGDH-04AE-OY 400W Servo Driver
  • Omron CPH-X40DT1-D PLC CPU Unit
  • Pilz PNOZ mm0.2p Safety PLC Mini 772002
  • Siemens 6SL3555-OPR01-0AA0 Sinamics G110M Panel
  • Sanyo PLC-XTC50L LCD Projector
  • SCE M68-2000 2-Axis Motion Controller
  • Omron CS1W-CT021 High-Speed Counter Unit