Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

TOSHIBA TOSBERT VF-AS3 series

F: | Au:FAN | DA:2025-12-30 | 904 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Automatic functions: automatic acceleration and deceleration, automatic torque increase, regenerative energy suppression control, reducing the difficulty of manual debugging

Fault handling: Supports 10 automatic retry functions, with an adjustable retry waiting time of 0-10 seconds, and fault records can be retained

(2) Interface and Communication System

1. Digital interface

Digital input: 14 programmable terminals (including 6 optional extensions), supporting 204 function assignments, compatible with positive/negative logic, compliant with IEC61131-2 logic type 1

Digital output: 3 programmable terminals (including 2 optional extensions), output capacity 24Vdc/50mA, supporting 262 function assignments

Pulse interface: The digital input terminal [S4] [S5] can receive pulse frequency signals (up to 30kbps), and the digital output terminal [FP] can output pulse signals (up to 30kbps, with a duty cycle of 50%)

2. Simulation interface

Analog input: 5 frequency command inputs (including 2 optional extensions), supporting signal types such as 0~10V, -10V~+10V, 4~20mA, etc. The input impedances are 31.5k Ω (voltage signal) and 250 Ω (current signal), respectively

Analog output: 2 programmable terminals, supporting 0~10V, 0~20mA, 4~20mA outputs, can allocate 54 monitoring parameters (such as frequency, current, voltage)

3. Communication capability

Built in interface:

Ethernet (dual port with switch): Supports EtherNet/IP, Modbus TCP, Webserver, enabling remote monitoring and control

RS485 (2 channels): Supports Toshiba inverter specific protocol Modbus RTU, Adapt to industrial bus networking

Optional extension protocols: PROFINET, DeviceNet, PROFIBUS DP, EtherCAT, CANopen, compatible with mainstream industrial control systems

(3) Security and protection functions

1. Core security design

Safe Torque Off (STO): Compliant with IEC61800-5-2 standard, cutting off the motor torque output does not affect the power supply of the control circuit, ensuring the safety of personnel and equipment

Insulation protection: Built in grounding detection function to avoid the risk of electric shock caused by poor grounding

Operation safety: It is forbidden to disassemble the front cover during operation. When disassembling the front cover and front small cover, the power must be turned off and the capacitor discharge must be confirmed to be completed

2. Comprehensive protection function

Specific functions of protection types

Electrical protection for overcurrent, overvoltage, undervoltage, short circuit (load side), ground fault (load side), input phase loss, output phase loss

Thermal protection for frequency converter overload, motor overload (electronic thermal protection), brake resistor overload, and frequency converter overheating

Mechanical protection stall prevention (during operation/acceleration), over torque protection

Other protective power sources include instantaneous power outages (≥ 15ms), EEPROM failures, RAM failures, and communication errors


Installation and wiring specifications

(1) Installation requirements

1. Installation foundation and space

Installation carrier: It must be fixed on a metal plate and used to assist in heat dissipation. It is prohibited to install it on flammable materials or non-metallic surfaces

Installation space:

Single installation: Reserve ≥ 10cm vertically and ≥ 5cm horizontally

Multiple parallel installations: distance between adjacent inverters ≥ 11mm to avoid hot air backflow

Environmental requirements: Install indoors, away from direct sunlight, corrosive gases, oil mist, metal dust, and avoid locations with severe vibrations

2. Handling and fixing

Transportation specifications: Models weighing ≤ 20kg can be transported by a single person, while models weighing > 20kg require cooperation from two people; VFAS3-6300PC~6750PC (A2Y machine base) needs to be transported by a crane and lifted through the top lifting hole. It is forbidden to grip the front cover or wiring hole during transportation

Fixing method: M5 (A1Y machine base) or M8 (A2Y machine base) screws are used for fixing, with tightening torques of 2.6N · m and 11.8N · m respectively, to ensure a firm installation

(2) Wiring specifications

1. Preparation before wiring

Power off requirement: Before wiring, all input power must be cut off, wait for at least 15 minutes, confirm that the charging light is off, and use a tester with a range of 1400Vdc or above to test the DC main circuit (between PA/+and PC/-) voltage to ensure it is ≤ 45V before operation

Personnel qualifications: Wiring work must be completed by electricians with professional qualifications to avoid accidents caused by incorrect wiring

2. Core wiring requirements

Power wiring: Connect the 3-phase power supply to the [R/L1], [S/L2], and [T/L3] terminals, and the voltage fluctuation should be within the range of -15% to+10% of the rated voltage (± 10% when operating at full load)

Motor wiring: Connect the 3-phase winding of the motor to the [U/T1], [V/T2], and [W/T3] terminals, and ensure that the phase sequence is correct to avoid motor reversal; It is strictly prohibited to directly connect the power supply to the output terminal

  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board
  • Valmet PMB 2R 542821-4A PCB Card
  • Metso Valmet A413001 CPU Module
  • Metso Valmet A413050 RSU 6 Serial Controller Unit
  • Valmet ABMB MT241 Input Mother Board
  • Valmet DAMATIC M851565 Keyboard
  • Valmet A413075 Ver05 FBC Board
  • VALMET K14891 FLEXI-U Operating Terminal
  • VALMET AUTOMATION MKB2 DAMATIC Keyboard