Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

YOKOGAWA CENTUM VP System (Vnet/IP Version)

来源: | 作者:FAN | 发布时间 :2025-12-18 | 22 次浏览: | Share:

YOKOGAWA CENTUM VP System (Vnet/IP Version)

Core components and software packages of the system

1. Core components (hardware)

Component Type Core Device Function Description

Operation monitoring HIS (Human Interface Station) human-machine interaction interface, supports desktop/console type, can integrate engineering functions

Engineering Station (ENG) system configuration and maintenance, supporting integration and deployment with HIS

Control class FCS (Field Control Station) core control computing unit, FCU model includes AFV10 /AFV30 /AFV40  (single/dual redundancy)

Advanced Process Control Station (APCS) for extended control and computation, improving factory operational efficiency

Gateway class GSGW/USGS/BIOS subsystem integrated gateway, supporting Modbus, OPC and other protocols

Network equipment L2SW/L3SW layer 2/3 switches, intra/inter domain communication relays (1Gbps rate)

The routing devices V net router and WAC router connect Vnet/IP to V net domain and wide area network (WAN) communication

2. Classification of core software packages

Software type represents model core function

Standard operation and monitoring functions of LHS 110 operation monitoring software

Operation monitoring software LHS1150 remote operation and monitoring server function

Operation monitoring software LHS4000 million tag processing (up to 1 million tags/system)

LHS5100 Standard Builder Function for Engineering Software (System Configuration)

Engineering software LHS5150 graphic builder (controls drawing creation)

Compliance software LHS5170 FDA 21 CFR Part 11 adaptation (access control, audit trail)

Extended function software LHS6530 report generation function

Extended Function Software LHS4450 Multi Project Connection Function (Hierarchical/Bidirectional Connection)


Network architecture and communication specifications

1. Core network (Vnet/IP)

Network attribute: Dual redundant control network based on Gigabit Ethernet (Bus1/Bus2), automatically switches in case of control communication failure

Topology structure: star topology

Communication speed: 1Gbps (between L2SW/L3SW), 100Mbps (between device and L2SW)

Transmission medium: Category 5e and above unshielded twisted pair (UTP), RJ-45 interface

Transmission distance: maximum 100m between device and L2SW; maximum 5km between L2SW (1000BASE-LX)

System size limitation:

Up to 64 Vnet/IP devices per domain

Up to 16 domains and 256 sites per system

2. Auxiliary network (Ethernet)

Purpose: File transfer, HIS/ENG communication

Protocol basis: IEEE802.3

Special configuration: When certain conditions are met, Vnet/IP Bus2 can be reused, with a communication bandwidth not exceeding 300Mbps

3. I/O communication bus (Class 3 core bus)

Bus type adaptation FCU transmission rate transmission medium maximum distance connection node limit

ESB bus AFV10 /AFV30 /AFv40  128Mbps dedicated cable (YCB301) 10m AFV10  up to 9; AFV30 /AFV40  up to 13

Optical ESB bus AFV30 /AFV40  128Mbps single-mode fiber (LC interface) 50km (relay module) same as ESB bus

ER bus AFV10  10Mbps coaxial cable (YCB141/YCB311) 185m (YCB141) maximum 14 per FCU, maximum 8 per bus

image.png

System configuration and expansion

1. System size limitation

Remarks on configuration item limit values

The maximum number of operation monitoring tags is 1 million/LHS4000 package needs to be enabled for the system, with a default maximum of 100000

The minimum system configuration of HIS x 1+ENG x 1+FCS x 1 HIS and ENG can be merged into one computer

Maximum number of FCS 114/system single FCS default 200 control drawings, maximum 500

Multi project connectivity supports hierarchical/bidirectional connectivity. Bidirectional connectivity is only applicable to CENTUM VP/CS 3000 projects

2. System expansion methods

Inter domain extension: Connect multiple Vnet/IP domains through L3SW, supporting up to 16 domains

Cross network expansion: Connect Vnet/IP and V net domains through V net routers, supporting a 3-layer hierarchical structure

Wide Area Expansion: Connect to WAN (including satellite communication) through WAC router to achieve remote device monitoring

Multi project extension: Implementing integrated monitoring of multiple projects through LHS4450 package (hierarchical/bidirectional mode)


Compliance and installation environment

1. Core compliance standards

FDA 21 CFR Part 11: Supports electronic record/signature, access control, and audit trail functionality

Safety standards: CSA C22.2 No.61010-1, CE Low Voltage Directive EAC CU TR 004

EMC standards: EN 55011 Class A, RCM, KC Marking

Explosion proof standards: CSA Non Intrinsic, FM Non Intrinsic, Type n/i (intrinsic safety)

2. Installation environment requirements

Environmental Parameters Desktop Equipment (HIS/ENG) Control Equipment (FCS/Node Unit)

Working temperature 5-40 ℃ 0-50 ℃

Relative humidity 20-80% RH 10-90% RH (non condensing)

Temperature change rate ± 10 ℃/hour ± 10 ℃/hour

Power supply voltage 100-120V AC ± 10%, 220-240V AC ± 10%, 24V DC ± 10%, same as left

Grounding requirement: independent grounding, resistance ≤ 100 Ω, independent grounding, resistance ≤ 100 Ω

Vibration requirements 1-14Hz (0.25mm amplitude), 14-100Hz (2m/s ²) are the same as the left


Integration of related systems

ProSafe RS: Safety Instrumented System (SIL 3 certified), can be integrated with CENTUM VP, and monitors SCS through HIS

PRM (Plant Resource Manager): Equipment Asset Management System, supporting equipment monitoring such as HART, FOUNDATION fieldbus, etc

Third party system: Third party PLC/PCS integration supporting Modbus, EtherNet/IP, OPC and other protocols through UGS/BIOS


Key issues

Question 1: What are the core advantages of the network architecture of the CENTUM VP system (Vnet/IP version)? What is the functional division between Vnet/IP and I/O communication bus (ESB/optical ESB/ER)?

answer

Core advantages of network architecture:

Dual redundancy design: The Vnet/IP control network adopts Bus1/Bus2 dual redundancy, which automatically switches in case of failure to ensure uninterrupted control communication;

High speed transmission: The communication speed within/between domains reaches 1Gbps, meeting real-time control requirements;

Strong scalability: Supports 16 domains/systems, 256 sites/systems, and achieves cross domain/wide area expansion through L3SW and routers.

Functional division of labor:

Vnet/IP: The system core control network is responsible for real-time control data and management information transmission between HIS, ENG, FCS and other sites;

ESB bus: I/O communication between FCS and local node units, with a speed of 128Mbps and a maximum transmission distance of 10m, compatible with the full range of AFV FCUs;

Optical ESB bus: Long distance I/O communication, based on single-mode fiber, with a maximum transmission distance of 50km, only compatible with AFV30 /AFV40 ;

ER bus: AFV10  Exclusive remote I/O communication, 10Mbps speed, maximum transmission distance of 185m, supports 4 buses/FCU.

Question 2: How does the CENTUM VP system meet FDA 21 CFR Part 11 compliance requirements? What are the key limitations to consider when expanding the system scale?

answer

FDA 21 CFR Part 11 Compliance Implementation:

Access control: Supports engineer/operator identity authentication, requires prior registration of username and password, and cannot operate without legal permission;

Permission confirmation: Independently verify whether the operator has specific operational permissions;

Audit tracking: Record engineering operations that affect product quality (such as FCS data downloads), including the operator, time, content, reason for changes, and traceability;

Data storage: Audit tracking data is stored on dedicated servers that support archiving and retrieval.

Key limitations of scale expansion:

Number of tags: default maximum of 100000 per system, maximum of 1 million after enabling LHS4000 package;

Domain and site: up to 16 domains/systems, 256 sites/systems, with a maximum of 64 Vnet/IP devices per domain;

FCS quantity: A maximum of 114 FCS per system, including up to 86 AFV30/AFV40 and up to 64 AFV10;

Control drawing: By default, a single FCS has 200 control drawings, but with the LFS1750 package enabled, the maximum is 500.

Question 3: What is the functional positioning of the core components (HIS/ENG/FCS) of the CENTUM VP system? What are the modes of multi project connection and what are the applicable scenarios?

answer

Functional positioning of core components:

HIS (Human Machine Interface Station): The operation and monitoring core provides functions such as graphical views, trend analysis, alarm management, etc. It supports desktop/console types and can integrate engineering functions;

ENG (Engineering Station): System configuration and maintenance, control logic design and equipment configuration are implemented through software packages such as LHS5100, which can be combined and deployed with HIS;

FCS (Field Control Station): controls the computing core, performs functional block operations, and I/O data exchange. The FCU supports single/dual redundancy to ensure control reliability.

Multi project connection mode and applicable scenarios:

Hierarchical Connection: The upper level CENTUM VP project monitors the lower level projects (supporting VP/CS 3000/CS 1000/CS), and only the upper level requires the installation of LHS4450 package, which is suitable for centralized monitoring of multi-level factories;

Bidirectional connection: The connected project can be monitored in both directions and is only applicable between CENTUM VPs or between VP and CS 3000. Both parties need to install LHS4450 package, which is suitable for multi factory collaborative control scenarios.

image.png

  • FOXBORO L0130AD L0130AE-0H Digital Input Module
  • FOXBORO 0399085B 0303440C+0303458A combination control module
  • FOXBORO SY-0399095E SY-0303451D+SY-0303460E DC power module
  • FOXBORO 0399071D 0303440C+0303443B Combination Control Board
  • FOXBORO RH924UQ controller module
  • FOXBORO E69F-TI2-S dual line temperature transmitter
  • FOXBORO 0399144 SY-0301059F SY-1025115C/SY-1025120E Combination Control Board
  • FOXBORO SY-60399001R SY-60301001RB SY-60702001RA/SY-61025006RA/SY-61025004RA/SY-61025001RA High performance industrial control module
  • FOXBORO 0399143 SY-0301060R SY-1025115C/SY-1025120E Sensor
  • FOXBORO 873EC-JIPFGZ Industrial Control Module
  • FOXBORO FBM230 P0926GU Communication Module
  • FOXBORO P0916PH P0916JS Input/Output Module
  • FOXBORO P0916PH P0916AL I/O module
  • FOXBORO 870ITEC-AYFNZ-7 Intelligent Electrochemical Transmitter
  • FOXBORO FBM207 P0914TD Voltage Monitor
  • FOXBORO FBM201D Discrete Input Module
  • FOXBORO P0923ZJ switch I/O interface module
  • FOXBORO P0923NG Intelligent Differential Pressure Transmitter
  • FOXBORO P0916KN power module
  • FOXBORO P0916KM I/A series module
  • FOXBORO P0916WE Terminal Cable
  • FOXBORO P0916VB power supply module
  • GE Hydran M2-X Transformer Condition Monitoring Device
  • FOXBORO P0916VL control module
  • FOXBORO P0916VC High Performance Terminal Cable
  • FOXBORO P0916WG system module
  • FOXBORO P0972ZQ interface channel isolation 8-input module
  • FOXBORO P0973BU high-frequency fiber optic jumper
  • FOXBORO P0926MX Splasher Confluencer
  • FOXBORO P0961S connector module
  • FOXBORO P0903NU system module
  • FOXBORO CM902WM control module
  • FOXBORO P0972VA ATS Processor Module
  • FOXBORO P0916Js digital input terminal module
  • FOXBORO PO961BC/CP40B control module
  • FOXBORO PO916JS Input/Output Module
  • FOXBORO PO911SM Compact Monitoring Module
  • FOXBORO P0972PP-NCNI Network Interface Module
  • FOXBORO P0971XU Control System Module
  • FOXBORO P0971DP Controller
  • FOXBORO P0970VB control module
  • FOXBORO P0970BP (internal) cable assembly
  • FOXBORO P0961EF-CP30B High Performance Digital Output Module
  • FOXBORO P0961CA fiber optic LAN module
  • FOXBORO P0926TM Modular I/O PLC Module
  • FOXBORO P0916BX series control system input/output module
  • FOXBORO P0916AG Compression Period Component
  • FOXBORO P0916AC I/A series module
  • FOXBORO P0912CB I/O Terminal Module
  • FOXBORO P0911VJ high-precision control module
  • FOXBORO P0911QC-C 8-channel isolated output module
  • FOXBORO P0911QB-C High Performance Industrial Module
  • FOXBORO P0903ZP Embedded System Debugging Module
  • FOXBORO P0903ZN control module
  • FOXBORO P0903ZL High Frequency Industrial Module
  • FOXBORO P0903ZE I/A series fieldbus isolation module
  • FOXBORO P0903NW Industrial Control Module
  • FOXBORO P0903NQ control module
  • FOXBORO P0903AA Industrial Control Module
  • FOXBORO FBM205 cable
  • FOXOBORO P0960HA I/A series gateway processor
  • FOXBORO P0926TP high-performance control module
  • FOXBORO P0926KL control module
  • FOXBORO P0926KK PLC system functional module
  • FOXBORO P0924AW wireless pressure transmitter
  • FOXBORO P0916NK differential pressure transmission cable
  • FOXBORO P0916JQ PLC module
  • FOXBORO P0916JP I/A series control module
  • FOXBORO P0916GG Digital Input Module
  • FOXBORO P0916DV I/A series digital input module
  • FOXBORO P0916DC Terminal Cable
  • FOXBORO P0916DB I/A series PLC module
  • FOXBORO P0914ZM recognition module
  • FOXBORO P0902YU control module
  • FOXBORO P0901XT Process Control Unit
  • FOXBORO P0800DV fieldbus extension cable
  • FOXBORO P0800DG Standard Communication Protocol Module
  • FOXBORO P0800DB Universal I/O Module
  • FOXBORO P0800DA Industrial Control Module
  • FOXBORO P0800CE control module
  • FOXBORO P0700TT Embedded System
  • FOXBORO P0500WX Control System Module
  • FOXBORO P0500RY Terminal Cable Assembly
  • FOXBORO P0500RU control module
  • FOXBORO P0500RG Terminal Cable
  • FOXBORO P0400ZG Node Bus NBI Interface Module
  • FOXBORO P0400GH fieldbus power module
  • FOXBORO FBM207B Voltage Monitoring/Contact Induction Input Module
  • FOXBORO FBM205 Input/Output Interface Module
  • FOXBORO FBM18 Industrial Controller Module
  • FOXBORO FBM12 Input/Output Module
  • FOXBORO FBM10 Modular Control System
  • FOXBORO FBM07 Analog/Digital Interface Module
  • FOXBORO FBM05 redundant analog input module
  • FOXBORO FBM02 thermocouple/MV input module
  • FOXBORO FBI10E fieldbus isolator
  • FOXBORO DNBT P0971WV Dual Node Bus Module
  • FOXBORO CP30 Control Processor
  • FOXBORO CM902WX Communication Processor
  • FOXBORO AD202MW Analog Output Module
  • FOXBORO 14A-FR Configuration and Process Integration Module
  • FOXOBORO 130K-N4-LLPF Controller
  • FUJI FVR004G5B-2 Variable Frequency Drive
  • FUJI FVR008E7S-2 High Efficiency Industrial Inverter
  • FUJI FVR008E7S-2UX AC driver module
  • FUJI RPXD2150-1T Voltage Regulator
  • FUJI NP1PU-048E Programmable Logic Control Module
  • FUJI NP1S-22 power module
  • FUJI NP1AYH4I-MR PLC module/rack
  • FUJI NP1BS-06/08 Programmable Controller
  • FUJI NP1X3206-A Digital Input Module
  • FUJI NP1Y16R-08 Digital Output Module
  • FUJI NP1Y32T09P1 high-speed output module
  • FUJI NP1BS-08 Base Plate​
  • FUJI A50L-2001-0232 power module
  • FUJI A50L-001-0266 # N Programmable Logic Control Module
  • GE GALIL DMC9940 Advanced Motion Controller
  • GE DMC-9940 Industrial Motion Control Card
  • GE IS200AEADH4A 109W3660P001 Input Terminal Board
  • GE IC660HHM501 Portable Genius I/O Diagnostic Display
  • GE VMIVME 4140-000 Analog Output Board
  • GE VMIVME 2540-300 Intelligent Counter
  • GE F650NFLF2G5HIP6E repeater
  • GE QPJ-SBR-201 Circuit Breaker Module
  • GE IC200CHS022E Compact I/O Carrier Module
  • GE IC695PSD140A Input Power Module
  • GE IC695CHS016-CA Backboard
  • GE IC800SS1228R02-CE Motor Controller