YOKOGAWA AFV40S, AFV40D Field Control Unit
Description
This GS covers the hardware specifications of the Field Control Unit (FCU) which is the core of the control function of the Field Control Station (FCS).
STANDARD SPECIFICATIONS
For the installation specifications and environmental conditions that are common to the systems, refer to “Integrated Production Control System CENTUM VP System Overview” (GS 33J01A10-01EN).
Installation Restrictions
To install Optical ESB Bus Node Units (ANB11) or ESB Bus Node Units (ANB10) in a remote location, use the Optical ESB Bus Repeater Master Module (ANT401 or ANT411) to connect them with an optical fiber cable. To install Optical ESB Bus Repeater Master Modules in the FCU, install a pair of modules in slots 1 to 6 from right to left according to the number of branches. In a single configuration, install the individual modules in slots 1, 3, and 5 in order from right to left. For details, see “Optical ESB Bus Repeater Module” (GS 33J60F51-01EN/GS 33J60F52-01EN). For the restrictions and notes for installing I/O modules, see “FIO System Overview” (GS 33J60A10- 01EN).
No. of Node Fan Units installable in Cabinet
The required number of Node Fan Units (ANFAN) varies depending on the total number of units (*1) that are installed in the cabinet. The required number of Node Fan Units needs to be specified as an option.
HARDWARE CONFIGURATION
When installing ESB Bus Node Units in the cabinet using ESB Coupler Module (EC401), up to 9/FCU (AFV40) can be installed
When installing ESB Bus Node Units in the cabinet using the ESB Coupler Module (EC402), up to 11/FCU (AFV40) can be installed.
Up to 5 node units can be installed at the front of the cabinet, and up to 6 node units at the rear.
email:1583694102@qq.com
wang@kongjiangauto.com