Zebra EPL2 Programming Complete Guide

Introduction: The positioning and advantages of EPL2

EPL2 (Eltron Programming Language 2) is the core page description language for Zebra desktop printers such as GK420, LP2844, G-Series, etc. Unlike the early line mode (EPL1), EPL2 adopts a "assemble first, print later" mechanism, which can efficiently process text, barcodes, graphics, and QR codes. Its syntax is concise and commands are compact, making it particularly suitable for quickly generating tags in resource constrained embedded environments.

This article is based on the official EPL Programming Guide (document number 14245L-003 Rev. A), which outlines common commands, form storage techniques, variable and counter usage, 2D barcode configuration, network settings (SGD), and common troubleshooting methods for engineers. It helps you quickly locate problems when developing or maintaining Zebra printing applications.


EPL2 Basic Concepts and Command Structure

2.1 Command syntax rules

Each EPL2 command starts with one or two case sensitive letters, followed by parameters (separated by commas), and ends with a line break (LF, ASCII 10). The carriage return (CR) will be ignored. The optional parts in the parameters are represented by square brackets, and the fixed data is enclosed in double quotation marks.

Example: A50,50,0,1,1,1, N, "Hello" - Print "Hello" at coordinates (50,50) using font 1, in normal orientation, without highlighting.

2.2 Image Buffer and Coordinate System

EPL2 uses a dot matrix coordinate system, with the origin (0,0) located in the upper left corner. The X-axis represents width, and the Y-axis represents height. All drawing commands (text, barcode, lines, boxes) are based on this coordinate system. Before printing, the image buffer must be cleared using the N command.

2.3 Media and Printing Control

Set label width (dots): q416 represents a width of 416 dots.

Q sets the label length and gap: Q160,24 represents 160 point labels+24 point gaps.

S sets the printing speed: S2 corresponds to 2 ips (inches/second), the specific value varies depending on the model.

D Set printing density: D5 range 0-15 (0 is shallowest, 15 is deepest).

P printing label: P1 prints one set, P2, Print 2 sets, with 3 copies per set.


Detailed explanation and practical skills of core commands

3.1 Text Printing - A Command

Command syntax: A p1, p2, p3, p4, p5, p6, p7, "DATA"

P1, p2: Starting coordinates (points)

P3: Rotation (0/1/2/3=0 °/90 °/180 °/270 °)

P4: Font selection (1-5 are built-in equal width Latin fonts; 8-9 are Asian double byte fonts; A-Z are soft fonts)

P5, p6: Horizontal/vertical magnification (1-6, 8, and 1-9)

P7: Normal (N) or reversed (R)

Tip: It is recommended to use the LE (Line Draw Exclusive OR) command to draw white text on a black background instead of the R parameter of the A command for more precise border control.

3.2 One Dimensional Barcode - B Command

The B command supports Code 39, Code 128, EAN/UPC, Interlocked 2 of 5, Codabar, Postnet, Planet, and more. The parameters include narrow bar width, wide bar width, barcode height, and whether to print readable characters.

Common problem: Barcode scanner cannot read barcodes in the "ladder" direction (rotated 90 °/270 °). Suggest using the "fence" direction (0 °/180 °) as much as possible. If rotating barcodes must be used, automatic optimization can be disabled through the oB command (but this may cause some scanners to fail to read, and Zebra does not guarantee compatibility).

Code 128 functional characters: Supports FNC1 – FNC4, automatically processes extended ASCII. For 5 or more consecutive extended characters, the printer automatically locks into extended mode; If there are less than 5, use the shift method.

3.3 Graphic Storage and Printing - GM/GG

GM "NAME" size: Download PCX format graphics to memory, size is in bytes. Binary data follows closely behind.

GG x, y, "NAME": Print stored graphics.

GW x, y, width, height, data: Directly write the original bitmap data into the image buffer (without storage).

Operation suggestion: Use DOS COPY/b command or Zebra Firmware Downloader to send graphic files. Do not add extra line breaks after graphic data.

3.4 Tables and Lines

LO x, y, width, height: Draw a black solid rectangle (covering existing content).

LW x, y, width, height: Draw a white rectangle (erase).

LE x, y, width, height: XOR line drawing can be used to invert existing graphics.

Form storage and automation of variables/counters

4.1 Form Concept

EPL2 allows storing complete label designs as "Forms". The form can contain fixed elements, variable fields, and counters, and can be printed by filling in variables each time it is called. This greatly reduces the overhead of duplicate data transmission.

Storage process:

FS "FORMNAME" - Start storing the form.

Define variables (V00,10, N, "Prompt"), counters (C0,5, L,+1, "-"), then add commands such as A/B and reference these variables.

FE - End storage.

Call process:

FR "FORMNAME" - Recall the form from memory.

Command followed by variable values (in defined order).

  • Sigmatek MDD111-1 DIAS Drive Axis Module
  • Sigmatek DKL042 05-024-042 Terminal Module
  • Sigmatek DM822 Control Module
  • Sigmatek CDM167 12-008-167-O Module
  • Sigmatek TAE151 Touch Display Unit
  • Sigmatek DCC041 SLIDES Module 05-700-041-D
  • Sigmatek AKM65M-ANC2GBB0 PM Servo Motor
  • Sigmatek ETT221 01-230-221 Operator Terminal
  • Sigmatek SLIDES DAM 124 Analog Module
  • Sigmatek AKM31C-ANCNGBB0 Servo Motor
  • Mannesmann Demag Sigmatek CP626 Central Unit
  • SIGMATEK 0332.554.03 Board 371071000154
  • SIGMATEK 12-250-021 Base Plate Back Panel CM5V020
  • SIGMATEK DM162 S-DIAS Digital Mix Module
  • DEMAG ERGOTECH 061 381 66 Sigmatek 9842.243.02 Circuit Board
  • SIGMATEK CP313-1 PLC Module
  • Sigmatek ETV0551-2 VARAN Touch Terminal
  • Sigmatek SDM 081 FS S-Dias Safety Module
  • DEMAG 05-250-023 Ergotech Motherboard with Sigmatek TMS012
  • Sigmatek CM5V020 12-250-023-K Wiring Base
  • Sigma Tek 5000B-37 Attitude Gyro Indicator
  • Sigmatek SDD120-2 DIAS Drive
  • Sigmatek CME221 Memory Module
  • Sigmatek DCP640 DIAS Central Unit
  • Sigmatek STO040 Safety Output Module
  • Sigmatek CET281 Control Panel
  • Sigmatek CIPC LX800 Demag NC5 CPU
  • Sigmatek DKL093 05-024-093 Terminal Module
  • Sigmatek AI088 20-009-088 Analog Input Module
  • Sigmatek CAI888 Analog Input Module
  • SIGMATEK CCA021 12-025-021 Analog Output Module
  • SIGMATEK 1104.579.05 Control Module
  • SIGMATEK SDI100 Digital Input Module
  • SIGMATEK C-IPC 256MB LX800 Compact Dias
  • SIGMATEK 9423.090.02 Control Module
  • SIGMATEK C-IPC 256 Power Supply 148498
  • SIGMATEK CAI025 Analog Input Module
  • SIGMATEK CTO166 Digital Output Module
  • SIGMATEK CP112 20-004-112 Processor Module
  • SIGMATEK CAI887 12-009-887 Safety Module
  • Sigma-Tek 4000B-31 Directional Gyro 1U262-002-42
  • Sigmatek C-IPC 256MB LX800 IPC Controller
  • Sigmatek C-IPC 01-450-031 Industrial PC LX800
  • Sigmatek C-IPC 256 Industrial PC Controller
  • Sigmatek CCP-531 PLC Processor Module
  • Sigmatek CDI163 Digital Input Module
  • Sigmatek ETV0501 VARAN Terminal 12-230-0501
  • Sigmatek CTMS020 C-DIAS Technology Module
  • Sigmatek CIV512 VARAN Switch Module
  • Sigmatek HU011 20-080-011 Interface Module
  • SIGMATEK SLIDES DAM 124 Module
  • SIGMATEK C-IPC 161 01-450-161L Industrial PC
  • SIGMATEK C-IPC 128MB VIA 733MHz 01-450-024-K
  • SIGMATEK 12-780-012 R8-IPC Geode LX800 Module
  • SIGMATEK CAM124 Analog Module
  • SIGMATEK S1 032-8AF61-R4 EZ Servo Motor
  • SIGMATEK CTO163 Digital Output Module
  • SIGMATEK CCP082 12-004-082 Processor Module
  • SIGMATEK CRCH081 C-DIAS Temperature Module
  • SIGMATEK PC322-K 01-310-322-K Industrial PC
  • SIGMATEK SDD310-2 Servo Drive
  • SIGMATEK AI084 Analog Input Module
  • SIGMATEK CRCH081 12-752-081 Temperature Module
  • Sigma-Tek 5000L-4 Attitude Gyro 1U284-001-3
  • SIGMATEK CM5V020 12-250-023-K Wiring Module
  • Sigma-Tek 4000H-6 Directional Gyro IU262-035-7
  • SIGMATEK Dias DCP160 05-004-160 Processor Module
  • SIGMATEK 0147.395.02 Control Module
  • SIGMATEK A1084 Control Module
  • SIGMATEK DI200 20-006-2000 Digital Input Module
  • Sigmatek DNC115 Encoder Module
  • Sigmatek DAM122 05-017-122 Analog Module
  • Sigmatek 9802.289.01 Control Board TA71 Display
  • Sigmatek TO127 20-007-127 Digital Output Module
  • Sigmatek DNC031 05-011-031 Digital Module
  • Sigmatek VI022 20-003-022 Interface Module
  • Sigmatek CAI085 Analog Input Module
  • Sigmatek CP111 S-DIAS CPU Module
  • Sigmatek CTMS030 Krauss Maffei Module
  • Sigmatek CAM123 Control Module
  • Sigmatek TAE732-P 01-240-732-P Touch Display Unit
  • Sigmatek MDM021 Digital Mixed Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek CST022 12-014-022 C-DIAS Module
  • Sigmatek SRO021 20-893-021 Safety Relay Output
  • Krauss Maffei MC5 Control System Sigmatek
  • Sigmatek DC061 Module 18-24VDC 300mA
  • Herrmann EVT0855 Ultrasonic Welder Touch Panel
  • Sigmatek CIV521 Control Module 1.4A 2W
  • Sigmatek DDI61 05-006-161 Digital Input Module
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • Cessna S3326-1 Sigma Tek 5000B-67 Gyro 1U149-015-9
  • SIGMATEK PS101 Power Supply Module
  • SIGMATEK 0332.554.03 Control Module 371071000154
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • SIGMATEK CDM163 Control Module
  • SIGMATEK VSV046 16-023-046 Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • SIGMATEK CTS051 12-053-051 Control Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • Sigmatek CSDI161 12-891-161 Safety Input Module
  • Sigma Tek 4000C-1 Directional Gyro Indicator
  • Sigmatek ETV0501 12-230-0501 VARAN Terminal
  • Sigmatek DDM165 SLIDES Module
  • Sigmatek N100 20-011-100 Control Module
  • Sigmatek AKM54K-ANC2R-B0 PM Servo Motor
  • Sigmatek CTO166 Digital Output Module
  • Sigmatek CP212-K 20-004-212-K CPU Module
  • Sigmatek CDI161 Digital Input Module
  • Sigmatek DCC080 05-700-080-2 Control Module
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SRO022 Relay Output Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK DSI021 SLIDES Siemens Interface
  • SIGMATEK DIAS DCP161 Module 05-004-161
  • Sigmatek ETT312 Built-in Touch Terminal
  • SIGMATEK DCP 643 DIAS Controller System
  • SIGMATEK CIO021 Multi I/O Module
  • SIGMATEK CTMS020 Control Module
  • Sigmatek CME 221 Memory Module
  • Sigmatek 0420.615.01 Control Board
  • Sigmatek CP111 20-004-111 CPU Module
  • Sigmatek 9405.065.03 Control Board
  • Sigmatek ETEK 01-450-032-K C-IPC 256MB Industrial PC
  • Sigmatek CTO163 12-007-163 Safety Output Module
  • Sigmatek TO081 20-007-081 Digital Output Module
  • Sigmatek SI021 20-022-021 Safety Input Module