Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Alcatel-Lucent EZ32-2 Board 3BA23265ADKE 01
    ❤ Add to collection
  • Alcatel-Lucent EZ32-2 Board 3BA23265ADKE 01

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥15276.00
      ¥16384.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.400KG
    • Quantity:
    • (Inventory: 527)
Description
<span style="font-size: 18px; font-family: arial;">Alcatel-Lucent EZ32-2 Board 3BA23265ADKE 01</span>

Alcatel-Lucent EZ32-2 Board (3BA23265ADKE 01) – Comprehensive Overview

The Alcatel-Lucent EZ32-2 Board, identified by the product code 3BA23265ADKE 01, is a high-density line interface card designed for use in time-division multiplexing (TDM) digital switching systems. This board provides 32 independent digital channels, typically supporting E1 (2.048 Mbps) or T1 (1.544 Mbps) line interfaces, and is commonly deployed in central office switches, digital access cross-connect systems (DACS), and legacy PBX environments. Its compact design and rich feature set make it essential for managing circuit-switched traffic in hybrid TDM/IP networks.

The EZ32-2 board is built around a dedicated DSP (digital signal processor) cluster that handles all channel-associated signaling (CAS) and common-channel signaling (CCS) protocols, including SS7 ISUP and PRI. Each of the 32 channels provides a full DS0 (64 kbps) timeslot, with the capability to aggregate multiple DS0s into Nx64 channels for data applications such as leased lines or ISDN. The board supports unframed, framed, and CRC-multiframe modes as per ITU-T G.704 standards.

Physical connectivity is provided by a high-density 50-pin telco connector (RJ-21X) or through four standard RJ-48C jacks, depending on the variant. The board includes built-in line termination (120 ohm for E1 or 100 ohm for T1) and automatic gain control (AGC) for receive equalization up to 6 dB of cable loss. Transmit pulse shaping ensures compliance with G.703 pulse mask requirements, minimizing spectral emissions and crosstalk.


Performance monitoring is integrated into the board's firmware. It continuously tracks line code violations, bipolar violations, errored seconds, and loss-of-frame events for each channel. These statistics are accessible via the system's management interface, enabling proactive maintenance and SLA verification. The board also supports loopback tests at the local, remote, and payload levels for fault isolation.

Synchronization is derived from the system backplane clock, but the board includes a secondary oscillator for holdover during reference loss. It also supports external clock input through an auxiliary connector, facilitating network-wide timing alignment.

Thermal and power characteristics are optimized for central office environments. The board consumes approximately 25 W from the -48 VDC backplane, with efficient DC-DC converters generating required onboard voltages. Cooling is via forced-air convection through the chassis, with the board's front panel including heat sinks on critical ICs.

Management is performed through the system's element manager, which provides per-channel provisioning, alarm reporting, and historical performance logs. The board is fully hot-swappable, enabling replacement without system downtime, provided the chassis supports live insertion.


Reliability is a key attribute. The EZ32-2 is built with industrial-grade components and conformal-coated to protect against humidity and dust. It meets NEBS Level 3 standards and carries CE and UL certifications. Its MTBF is estimated at 350,000 hours.

Typical use cases include connecting digital PBXs to central office switches, aggregating E1/T1 circuits for mobile backhaul, and serving as a channel bank for legacy data services. The EZ32-2 board ensures seamless integration of TDM traffic into modern packet-switched networks via circuit emulation services.

In conclusion, the Alcatel-Lucent EZ32-2 Board (3BA23265ADKE 01) is a reliable, high-density solution for TDM interface needs, offering comprehensive diagnostics, flexible timing, and robust construction, making it a cornerstone for carrier-grade telecommunications equipment.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide
  • Bosch Rexroth VT-MSPA Proportional Valve Amplifier Configuration and Troubleshooting Guide
  • Bosch Rexroth CDH1/CGH1/CSH1 Square Cylinder Selection and Compression Rod Verification
  • Bosch Rexroth CD/CG/CS Hydraulic Cylinder Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide
  • Bosch Rexroth MSK Servo Motor Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth IndraMotion MTX CNC System Selection and Backup Guide
  • GE MV3000 Inverter Cooling Fan Replacement and Upgrade Plan
  • Bosch Rexroth Indramat DIAX04 HDD/HDS Drive Controller Planning Guide
  • Technical Analysis and Selection Guide for Bosch Rexroth AZPF Gear Pump
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller