Product positioning: A "out of the box" amplifier designed for position feedback proportional valves
Bosch Rexroth VT-MSPA is an analog modular valve amplifier (component series 2X) designed for proportional directional valve and pump control without electrical position feedback. It is specifically designed for convenient selection of industrial hydraulic Rexroth valves - the valve characteristic curve is pre stored inside the equipment, and users can select the valve type by rotating the switch and optimize the parameters through buttons. All valve parameters can be adjusted.
Two variants and four ordering models:
VT-MSPA1 (single electromagnet): Command value 0...+10 V or 4... 20 mA;
VT-MSPA2 (dual electromagnet): Command value 0... ± 10 V or 4... 20 mA, maximum electromagnet current set according to A/B electromagnet respectively.
Model Material Number Instruction Value Form
VT-MSPA1-2X/A5/000/000 R901439034 Voltage 0...+10 V
VT-MSPA1-2X/F5/000/000 R901439036 Current 4... 20 mA
VT-MSPA2-2X/A5/000/000 R901439037 Voltage 0... ± 10 V
VT-MSPA2-2X/F5/000/000 R901439038 current 4... 20 mA
The device weighs only 0.14 kg and measures 114 × 22.5 × 99 mm. It is installed in a rail type (TH35-7.5 or TH35-15, EN 60715) and has 12 detachable spring terminals.
Complete solution of functional link: 11 level signal processing from command value to electromagnetic current
The internal signal chain of the amplifier can be decomposed into the following links (block diagram numbers in parentheses):
1. Power unit (1): Equipped with a built-in current limiting device to suppress peak closing current and integrated reverse polarity protection. Power supply 24 V DC (minimum 18 V - maximum solenoid current 0.8 A for valves is 21 V; maximum 36 V; residual ripple 40... 400 Hz, maximum 2.5 Vpp and must comply with allowable limits); Maximum power consumption<48 W; external 3.15 A delay fuse protection; Maximum current consumption<2 A, maximum closing current<4 A).
2. Instruction value and summation device (3): "Internal instruction value"="External instruction value" at the input of differential amplifier (2)+zero offset (4, adjustable "Z/B" in standard settings). Hydraulic directional logic (4W... valve): P → A, B → T flow is generated by the command values of electromagnet B, 0...+10 V or 12... 20 mA; Generate P → B, A → T flow through electromagnet A, 0... -10 V or 12... 4 mA; The instruction value (5) can be reversed in expert settings. Positive command value of pressure valve=pressure rise at the valve. During normal operation, internal command values can be measured at the "v" measuring socket.
3. Slope generator (6/7): Limit the slope of the instruction value. Choose between a single slope (6, all slopes share the same time, default value) or a 4Q/2Q slope (7, different times in each quadrant, expert setting) - the characteristic curve generator does not affect the slope time. The adjustable range of slope time is 0.01... 30 seconds.
4. Instruction value attenuator "G" (8): reduces the amplitude of the instruction value, with an adjustable range of 70... 110% (when the instruction value is 100%).
5. Characteristic curve generator (9): Adapt the pre stored valve characteristic curve to the actual hydraulic and control technology conditions. Expert settings adjustable: lead current "B", step "S", maximum current "G" (VT-MSPA2 can be set for electromagnet A and B separately). Step level 0... 50%.
6. Current controller (10): Record the current of the electromagnet and compare it with the command value, and compensate for the difference (PID closed-loop).
7. Clock generator (11) and power output stage (12): The output stage generates chopper electromagnet current; The clock frequency of Rexroth valve sometimes varies with the command value and/or operating voltage (set range 95... 505 Hz, depending on the selected valve). The current of the electromagnet is limited to the maximum allowable current (maximum 2.7 A) determined by the set valve, and the output stage is protected against short circuit; When there is internal interference signal or missing enable, the output stage is turned off. Electromagnetic cable (1.5 mm ²) with a maximum length of 50 meters.
8. Digital Input DI (13): Four optional functions - Enable (factory settings); VT-MSPA1 has no function (permanently enabled)/VT-MSPA2 instruction value inversion (permanently enabled); Slope ON/OFF (permanently enabled); Single/quadrant ramp switching (permanently enabled). Digital input XH2: ON (valid) 11... 36 V, OFF (invalid) -3... 5 V, RE>50 k. Special valve example: The switch position 0-5 of the proportional directional valve "4WRPH 6... SO855" is fixed at the command value ± 10 V and the command value is reversed (permanently enabled).
9. Digital output (15): The device outputs a "ready" signal when there are no disconnections, no internal errors, and UB ≥ UB min. Simulate actual output X2A: IA is 0... -2.5 V (V ≙ A), IB is 0...+2.5 V, and the minimum load impedance is 1 k Ω.