Product positioning and scope of application
Rexroth IndraControl VDP 16.3, VDP 40.3, and VDP 60.3 are passive operation and visualization terminals launched by Bosch Rexroth. They do not have computing capabilities and must be used in conjunction with Bosch Rexroth control cabinet PCs (such as VSB 40.3, VSP xx.3, VBP 40.3, VPP xx.3 series) to form a complete PC based operation terminal solution. Typical application areas include handling and assembly systems, packaging and food processing machinery, printing and paper processing machinery, machine tools, and wood processing machinery.
This manual applies to all variants with model codes starting with "VDPxx. 3..." and excluding "... CG..." - models with CG codes are versions built into the system chassis and require separate reference to the corresponding documentation. The supporting documents include VAP 01 power unit (R911339613), VAU 01.1 UPS uninterruptible power supply (R911336867), VAC 01 Y distributor (R911336973), and V series equipment project planning manual (R911343901).
Comparison of Technical Data for Three Major Models
Project VDP 16.3 VDP 40.3 VDP 60.3
Display screen 305 mm TFT (12 "), 800 × 600 pixels, 16.7 million colors 381 mm TFT (15"), 1024 × 768 pixels, 16.7 million colors 483 mm TFT (19 "), 1280 × 1024 pixels, 16.7 million colors
Operation mode: Touch screen (DB)/button (BK) Touch screen (DE), button (BI), dual operation (DF), touch+switch element (DI) Touch screen
Current consumption 0.85 A 1.05 A 1.7 A
Power consumption 20 W 25 W 40 W
Weight 4.0 kg 5.8 kg 7.3 kg
Panel width x height 350 x 290 mm (AK customized version 360 x 300 mm) 407 x 370 mm (AL customized version 417 x 380 mm) 483 x 400 mm
Unified specifications for all models: front panel IP65 (DIN EN 60529), NEMA Type 1 (front), back panel IP20; Power supply DC 24V, requires the use of a 24V power supply unit that complies with DIN EN 60742 (classification VDE 0551), recommended VAP01.1H-W23-024-010-NN (part number R911171065); The maximum current for a single USB port is 500 mA, and the total current for all USB ports is 1 A. The front panel USB ports (if any) come with an IP65 protective cover. Customized version (VDP 16.3AK designed for Bosch in the food industry) VDP 40.3AL、 The FE/FI design of 60.3 has slight differences in appearance and interface configuration, such as the AK and AL versions having no USB connection.
Electrical installation dimensions: VDP 16.3 opening 318 × 275 mm, installation depth 41 mm; VDP 40.3 opening 375 × 338 mm; VDP 60.3 opening 453 × 370 mm. All models require 8 mounting bolt holes with a diameter of 5 mm.
Certification and Environmental Conditions
The equipment complies with the EU EMC Directive 2004/108/EC and adopts DIN EN 61000-6-4 (Industrial Environment Emission, September 2007 edition) and DIN EN 61000-6-2 (Industrial Environment Immunity, March 2006 edition) harmonic standards; Certified by UL508 (Industrial Control Equipment) and CSA C22.2 No. 142-M1987, UL file number E210730- however, certification is only valid for delivery in its original condition, and any modifications must be revalidated for CE and UL/CSA compliance.
Environmental conditions: Operating temperature+5 to+45 ℃, with a maximum temperature change rate of 3 K/minute; Transportation: -20 to+60 ℃ (climate level 2K2), storage: 1K2; relative humidity: 5-85% (operation), absolute humidity: 1-29 g/m ³, condensation is prohibited; Operate at an altitude of 3000 meters (EN 61131-2). Mechanical strength: Operating vibration of 10-150 Hz, acceleration of 1 g at 57-150 Hz (EN 60068-2-6); Transportation/storage impact of 15 g, 11 ms (EN 60068-2-27); Pollution level 2, overvoltage category 2.
Key points for selecting accessories and cables
Y distributor VAC 01 (VAC01.1S-YD1-NNN, part number R911171187): Used to connect two operation display terminals with the same resolution and version to the same control cabinet PC. It can cascade up to four devices - when expanding the display, the resolution of the two devices must be consistent.
CDI connection cable (RKB0008 series, part number R911171484 onwards): available in twelve lengths ranging from 0.5m to 50m. Key constraint: Two cables (data line XSER+image line XVID) are always required between VxB and VDP. The cables listed must be used, as non specified CDI cables may cause malfunctions.
USB connection cable (RKB0019 series): 0.5/1/3/5 m. When using UPS in strong noise environments, a high anti-interference USB cable (RKB0050 series, part number R911172944/45) must be used between the control cabinet PC and the VAU 01.1 U with communication interface to avoid potential malfunctions.
UPS uninterruptible power supply (VAU01.1U-024-024-240-NN, part number R911171024, DC 24 V/240 W with USB interface). Please refer to the VAP 01 manual for the selection of power supply units. The touch screen belongs to the category of vulnerable parts and can only be operated with fingers or a dedicated stylus (part number 1070923266). Improper use of objects can damage the touch screen or front panel.