  • GE DS200TVCOG1A Isolation Volt Feedback Board
    ❤ Add to collection
  • GE DS200TVCOG1A Isolation Volt Feedback Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TVCOG1A Isolation Volt Feedback Board

    • ¥22000.00
      ¥24520.00
      ¥22000.00
      ¥22000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE DS200TVCOG1A Isolation Volt Feedback Board


GE DS200TVCOG1A Isolation Volt Feedback Board

Part Number DS200TVCOG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TVCOG1A is an Isolated Voltage Feedback Board manufactured and designed by General Electric as part of the Mark V Series used in GE Drive Control Systems. An Isolated Voltage Feedback Board is an electronic circuit or module designed to provide voltage feedback in a system while maintaining electrical isolation between input and output. It is commonly used in various applications, including power supplies, motor control systems, and instrumentation. 

The primary purpose of the isolated voltage feedback board is to monitor the output voltage of a power supply or any other voltage source and provide accurate feedback to a control system. By doing so, it helps regulate and stabilize the output voltage, ensuring that it stays within the desired range. Isolation in this context refers to the electrical separation between the input and output sides of the board. This is crucial in scenarios where there might be potential differences, noise, or high voltage that could harm the control system or the operator. Isolation helps protect sensitive electronics and ensures safe and accurate feedback. Isolated voltage feedback boards typically employ isolation techniques like magnetic isolation, opto-isolation, or capacitive coupling to achieve electrical separation. 

These methods prevent direct electrical contact between the input and output circuits while allowing the necessary communication of voltage information. FEATURES: Isolation Barrier: The primary feature of an isolated voltage feedback board is its ability to provide electrical isolation between the input and output circuits. This isolation prevents current flow and voltage transfer between the two sides, ensuring safety and protecting sensitive electronics. 

 High Isolation Voltage Rating: Isolated voltage feedback boards typically have a high isolation voltage rating, which indicates the maximum voltage difference that can be safely sustained across the isolation barrier. Input Voltage Range: The board should support a wide range of input voltage levels to accommodate various power supply or voltage source configurations. Voltage Sensing Accuracy: Precise voltage sensing is crucial for accurate feedback. These boards are designed to provide high accuracy in measuring the output voltage of the system. Low Voltage Drift: Voltage drift refers to the change in output voltage reading over time or due to temperature variations. Isolated voltage feedback boards aim to have low voltage drift to maintain stability in the feedback loop. Overvoltage and Overcurrent Protection: The board may include protection mechanisms to safeguard both the board itself and the connected systems from voltage spikes or excessive current.I

ABOUT THE DS200TVCOG1A

This device is a printed circuit board that is available from AX Control Inc. This PCB is a unit that is designated as an Isolated Voltage Feedback Card. This card is outfitted to process the feedback from the isolated voltage of the Speedtronic Mark V module that it is designed for. The Speedtronic Mark V units are a series of monitoring and management devices that were, like the DS200 printed circuit boards, developed by the industrial automation division of General Electric. The Mark V units are able to match up and control the dynamic applications of both gas powered and steam powered industrial turbines. These turbines that they are attached to are responsible for power generation based processes and systems.

Hardware Tips and Specifications

This DS200TVCOG1A printed circuit board from General Electric utilizes its own particular series of hardware component inclusions and specifications to achieve functional status within its greater Mark V Turbine Control System Series. For starters, this DS200TVCOG1A printed circuit board or PCB for short has an assembly elevated by many of the various voltage-limiting hardware components standardized to the Mark V Series; including various rectifiers, diodes, integrated circuits, and capacitors. In addition to these components, the entire base circuit board of this DS200TVCOG1A Isolated Voltage Feedback Card should be well-protected from basic daily wear and tear damage through use of its normal style of Mark V Series printed circuit board coating. The normal style of PCB coating applied to this DS200TVCOG1A product offering envelops and protects individual hardware elements on the DS200TVCOG1A PCB's base circuit board on a functional priority basis. This DS200TVCOG1A Isolate Voltage Feedback Card's base circuit board is permeated in several sites by factory-drilled holes, which have been included for installation purposes. Each one of these factory-drilled holes has been ringed with an insulated material in observance of this DS200TVCOG1A product's potentially-present damaging surface voltages. The DS200TVCOG1A Isolated Voltage Feedback board is outfitted with a set of LED lights which indicate to any technicians or on-site operators if the unit requires a replacement fuse.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide