Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • DS3800DISA | General Electric Signal Isolated Auxiliary Board Mark IV
    ❤ Add to collection
  • DS3800DISA | General Electric Signal Isolated Auxiliary Board Mark IV

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    DS3800DISA | General Electric Signal Isolated Auxiliary Board Mark IV
    • ¥3455.00
      ¥9898.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 3)
Description
DS3800DISA | General Electric Signal Isolated Auxiliary Board Mark IV

DS3800DISA | General Electric Signal Isolated Auxiliary Board Mark IV

Product Description P/N: DS3800DISA DESCRIPTION / SPECIFICATIONS Description The DS3800DISA is a Signal Isolated Auxiliary Board for the Mark IV series. It provides isolated signal processing to ensure integrity and stability within industrial control systems. This board is designed for integration with larger motherboards, supporting reliable operation by minimizing electrical interference. The DS3800DISA is suitable for use in environments requiring precise signal isolation and protection in the Mark IV control architecture.

 Technical Specifications Part Number DS3800DISA Manufacturer General Electric Series Mark IV Product Type Signal Isolated Auxiliary Board Number of Channels 12 Operating Temperature -30 to 55 degrees Celsius Size 8.25 cm high x 4.18 cm Information About DS3800DISA The DS3800DISA is a Signal Isolated Auxiliary Board developed by General Electric as part of the Mark IV series of industrial control systems. This auxiliary board is specifically designed to provide signal isolation capabilities, ensuring that electrical signals within the system remain stable and free from interference. The DS3800DISA plays a crucial role in maintaining the integrity of control signals, which is essential for the accurate operation of various industrial processes managed by the Mark IV control system. 

 This signal isolated auxiliary board features 12 channels, allowing it to handle multiple signals simultaneously. Each channel is designed to isolate and process individual signals, thereby preventing cross-talk and ensuring that signals are transmitted without degradation or interference. The use of isolated channels is critical in industrial environments where multiple signals are present and where maintaining signal clarity is paramount for system performance and reliability. By providing isolated pathways for each signal, the DS3800DISA helps to maintain the accuracy and reliability of control operations, which is essential for safety and efficiency in industrial applications. 

 The DS3800DISA is engineered to operate effectively within a wide temperature range, with an operating temperature specification of -30 to 55 degrees Celsius. This temperature range allows the board to function reliably in various environmental conditions, including extreme cold and heat. This capability is essential for industrial settings where temperature variations are common, such as in outdoor installations, manufacturing plants, and power generation facilities. The board鈥檚 ability to maintain performance across a wide temperature range ensures that it can be deployed in diverse environments without compromising functionality. In terms of physical dimensions, the DS3800DISA measures 8.25 cm in height and 4.18 cm in width. These compact dimensions make it suitable for integration into existing control system architectures without requiring significant space. 

The small size of the board allows for flexible installation options, making it an ideal choice for use in control panels, enclosures, or other tight spaces within industrial equipment. Despite its compact size, the DS3800DISA offers robust signal isolation capabilities, making it a valuable component for enhancing system performance. The DS3800DISA is part of General Electric鈥檚 Mark IV series, a well-established line of industrial control systems known for their reliability and effectiveness in managing complex industrial processes.

 The integration of the DS3800DISA into the Mark IV system enhances the system鈥檚 overall capability to manage and isolate signals, thereby improving operational accuracy and reducing the likelihood of signal-related errors. As part of the Mark IV series, the DS3800DISA benefits from the rigorous design and manufacturing standards that characterize General Electric鈥檚 industrial control products, ensuring high quality and long-term reliability. One of the key benefits of the DS3800DISA is its role in enhancing system safety. By isolating signals, the board helps to prevent unintended interactions between different parts of the control system, which could otherwise lead to malfunctions or hazardous situations.

 Signal isolation also protects sensitive components from electrical noise and voltage spikes, further contributing to the safe and reliable operation of the control system. This protection is particularly important in environments where equipment is exposed to electromagnetic interference or where there is a risk of electrical faults. The DS3800DISA鈥檚 functionality is complemented by its ease of integration into existing systems. The board is designed to work seamlessly with other components of the Mark IV series, ensuring that it can be incorporated into control setups without requiring extensive modifications. This compatibility simplifies the process of upgrading or expanding control systems, making the DS3800DISA a practical solution for facilities looking to enhance their signal management capabilities.

 In summary, the DS3800DISA Signal Isolated Auxiliary Board is a critical component for industrial control systems, providing essential signal isolation and protection features. With its 12-channel configuration, wide operating temperature range, and compact size, it is designed to meet the needs of diverse industrial applications. The DS3800DISA supports the integrity and reliability of control signals, contributing to the safe and efficient operation of General Electric鈥檚 Mark IV control systems. Its role in enhancing signal clarity and reducing interference makes it an invaluable asset for maintaining the performance and safety of industrial automation and control environments. 

 Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration