GE DS3800HROA Relay Output Board
GE DS3800HROA Relay Output Board
Part Number DS3800HROA Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS3800HROA is a Relay Output Board developed by GE. It is a part of Mark IV control system. The Mark IV control system is a type of control system used for gas and steam turbines, and it is designed to provide advanced control and monitoring capabilities. It is designed to operate within a 24 VDC power supply range and has a maximum output rating of 125 VAC/125 VDC at 5A per point.
This board features a total of 24 outputs and is equipped with LED indicators that provide status information for each output channel. Mark VI Unit Configuration The Mark VI interface uses Ethernet Global Data messages for periodic data, and the ALM protocol for alarms and SOE messages. The information is transferred directly from the EGD global memory into PI, and the Digital Exception Messages go through the Historian System Service (HST). Configuration Files The Mark VI is configured primarily through a set of ASCII text files and the Toolbox file. These files are divided into several directories based on the functions performed.
Compatibility
ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page.
ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU.
ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0).
ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software.
ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network.
Module features include:
ƒ Support for all standard data rates (125K, 250K, 500K)
ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave
ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master
ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS
ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging
ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device
ƒ Support for configuration of the global scan rate
ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis
ƒ Support for PLC-application initiated explicit messaging via a COMMREQ
ƒ Master can be configured to operate as a slave simultaneously with master operation
ƒ Configurable fault behavior on loss of communication
ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable)
ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero)
ƒ Firmware update via service port on module
Our Main Brands
· - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
· - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
· - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
· - Bently Nevada 3300 System, 3500 System
· - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
· - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
· - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider