Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TRPAH2A - PRIMARY TRIP AEP
    ❤ Add to collection
  • GE IS200TRPAH2A - PRIMARY TRIP AEP

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200TRPAH2A - PRIMARY TRIP AEP
    • ¥12000.00
      ¥24520.00
      ¥12000.00
      ¥12000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS200TRPAH2A - PRIMARY TRIP AEP

GE IS200TRPAH2A - PRIMARY TRIP AEP

Part Number IS200TRPAH2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TRPAH2A is an Aeroderivative Turbine Primary Trip terminal board developed by GE. Do not inadvertently connect the 240 V ac and dc voltages in 240 V ac applications. The peak voltage will exceed the MOV rating, causing the device to fail. Most ac supplies have a grounded neutral, and if an inadvertent connection between the 125 V dc and the ac voltage is made, the sum of the ac peak voltage and the 125 V dc is applied to MOVs connected between dc and ground. In 120 V ac applications, however, the MOV rating can withstand the peak voltage without failing. 

 IS200TRPAH2A Features As part of the Mark VIe control system, the board interface with PTUR / YTUR I/O packs and TTUR terminal boards. The following are the inputs and outputs:/p> Twelve passive pulse rate devices (four per R/S/T section) measuring turbine speed by sensing a toothed wheel. Alternatively, six active pulse rate inputs (two per TMR section) Two 125 V dc TMR voted output contacts for the trip coil to the main breaker coil. Four 24-125 V dc voltage detection circuits for trip string monitoring One 24-125 V dc 'Fail-safe' ESTOP input for disabling trip relays. Signals from TMR systems fan out to the PR3, PS3, PT3, JR4, JS4, and JT4 connectors. Installation TTL pulse rate pick-ups, voltage detection, E-Stop, and the breaker relay are all connected to I/O terminal block TB1. TB2 is wired with passive pulse rate pick-ups. Each block is held together with two screws and has 24 terminals that accept wires up to #12 AWG. To the left of each terminal block is a shield termination strip connected to chassis ground. 

JP1 and JP2 enable or disable fanning of the R section pulse rate pickups to the S and T PTURs or YTURs. System Design The TRPA board is intended for use in two different ways. When a TRPA terminal board is used to connect three PTUR or YTUR I/O packs to a TTUR terminal board, three cables with DC-37 pin connectors on each end can be used. The TRPA provides two contact-voted trip relay outputs, ESTOP, and four voltage sensors in this mode of operation. TTUR has the standard set of features described for that board. The TRPA speed inputs are inactive and should not be used with this board configuration. The TRPA board can also be used with three I/O packs attached to it directly. The speed inputs to TRPA become active paths into the I/O pack in this mode of operation, allowing for a single terminal board primary trip solution. 

 Trip Relays Trip relays are constructed from groups of six individual form A devices arranged in a voting pattern. A conduction path through the set will be established if two controllers vote to close. Because detecting a shorted relay is critical for maintaining tripping reliability, each set of relays has a sensing circuit installed. When the relays are commanded to open and voltage is applied across the relays, the circuit detects whether one or more relays are shorted. This signal is sent to the I/O pack, which generates an alarm. To avoid a false indication if one I/O pack votes to close the relay while the other two I/O packs vote to open, the TRPA sensing circuit uses relay commands from all three packs. Configuration Jumpers JP1 and JP2 control the fanning of the four passive speed pickups in the R section to the PTURs or YTURs in the S and T sections. To fan the 4 R speed input to the other two TMR sections, place the jumper over the pin pairs.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

Features 

▪ Contains 10 Mbytes of battery-backed user memory and 10 Mbytes of non-volatile flash user  memory. 

▪ Provides access to bulk memory via reference table %W. 

▪ Configurable data and program memory. 

▪ Programming in Ladder Diagram, C, Structured Text, and Function Block Diagram. 

▪ Supports auto-located Symbolic Variables that can use any amount of user memory. 

▪ Reference table sizes include 32Kbits for discrete %I and %Q and up to 32K words each for  analog %AI and %AQ. 

▪ Supports Series 90-70 discrete and analog I/O, communications, and other modules. For a  list of modules supported, refer to the PACSystems RX7i Installation Manual, GFK-2223. 

▪ Supports all VME modules supported by Series 90-70. 

▪ Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server  and FTP connections. 

▪ Supports up to 512 program blocks. Maximum size for a block is 128KB. 

▪ Test Edit mode allows you to easily test modifications to a running program. 

▪ Bit-in-word referencing. 

▪ Battery-backed calendar clock. 

▪ In-system upgradeable firmware. 

▪ Three isolated serial ports: an RS-485 serial port, an RS-232 serial port, and an RS-232  Ethernet station manager serial port. 

▪ The embedded Ethernet interface provides: 

- Data exchange using Ethernet Global Data (EGD) 

- TCP/IP communication services using SRTP 

- Support for SRTP Channels, Modbus/TCP Server, and Modbus/TCP Client 

- Full programming and configuration services 

- Comprehensive station management and diagnostic tools 

- Two full-duplex 10BaseT/100BaseT/TX (RJ-45 Connector) ports with an internal network  switch providing auto-negotiated network speed, duplex mode, and crossover detection. 

- User-configurable Redundant IP address 

- Time synchronization to SNTP time server on Ethernet network (when used with  Release 5.00 or later CPU module).


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Honeywell Fusion4 MSC-L Multi Stream Loading Controller
  • Honeywell IPC 620-06 Programmable Controller
  • Honeywell Enhanced Micro TDC 3000 Control System
  • Honeywell Expert LS I/O System
  • Honeywell Expert PKS Universal Process Cabinet
  • KEBA KeConnect I/O: Modular Industrial Automation I/O System
  • KEBA FM 299/A GA1060 fieldbus main module
  • KEBA KeControl C1 CP 03x: Highly Integrated Embedded Industrial Controller
  • KEBA KeControl series controllers
  • KEBA KeConnect C5: High density modular IO system empowering industrial automation
  • KEBA DI 260/A Digital Input Module
  • Kollmorgen SERVOSTAR 600 (S600) series digital servo drive
  • Kollmorgen S300 Servo Drive Application Guide
  • Kollmorgen H series brushless servo motor and Silverline driver
  • Kollmorgen Servo System Product Guide
  • KOLLMORGEN S200 High Performance Compact Brushless Servo Drive
  • KOLLMORGEN IDC EC Series Electric Cylinder Configuration and Application Guide
  • Selection and Application of KOLLMORGEN E/H Series Stepper Motor
  • Kollmorgen AKD/S700 series servo drive
  • KOLLMORGEN Digifas-7200 Digital Servo Amplifier Application Guide
  • Kollmorgen SERVOSTAR-CD servo drive hardware installation and system configuration
  • MOOG QAIO 16/4 Analog I/O Module Technology Analysis and Application Guide
  • MOOG G128-809A DIN rail power supply
  • MOOG MSD Multi Axis Servo Drive System (DC-AC)
  • MOOG DM2020 Multi axis Servo Drive
  • MOOG M3000 ® Control system and MSC servo controller
  • MOOG G123-825-001 DIN rail buffer amplifier
  • MOOG Servo Electronics Products
  • MOOG T161 Series Rack Mount Digital Brushless Motor Controller
  • Motorola PTX series (PTX700/760/780) portable walkie talkies
  • MOTOROLA MVME2400 series VME processor module
  • MOTOROLA CPCI-6020 CompactPCI Single Board Computer
  • Motorola MVME162 Embedded Controller
  • Reliance Electric Engineering Drive System and DBU Dynamic Braking Unit
  • RELIANCE ELECTRIC INVERTRON DBU Dynamic Braking Unit
  • Reliance 57C413B/57C423 common memory module
  • Rockwell Automation AutoMax™ Distributed Power System
  • Reliance Electric AutoMax Programming Executive V3.5
  • Deep Analysis and Industrial Control Application of Reliance DCS 5000 Enhanced BASIC Language
  • Rockwell Automation MD60 AC Drive
  • COTEK SD Series Pure Sine Wave Inverter
  • RELIANCE ELECTRICI GV3000/SE AC General Purpose (Volts/Hertz) and Vector Duty Drive Version 6.06
  • ABB SACO16D1 Alarm Display Application Guide
  • REXROTH Indramat PPC-R Modular Controller Application Guide
  • REXROTH EcoDrive Cs series AC servo drive system
  • REXROTH IndraControl VEP Embedded Terminal Project Planning and Operation Guide
  • REXROTH IndraDyn S MSK series synchronous servo motor
  • REXROTH 4WRPEH series Directional control valves
  • REXROTH WE 6X series directional valve
  • REXROTH VT-HNC100... 3X Series Digital Axis Controller
  • REXROTH BTV04.2 Micro Control Panel Functions and Applications
  • REXROTH MKD Explosion proof Synchronous Motor Application Guide
  • REXROTH 4WRTE type electro-hydraulic proportional directional valve
  • REXRTOH IndraControl VDP series operation display
  • REXRTOH MSK series synchronous servo motor
  • REXRTOH ECODRIVE DKC Series Drive Controller Comprehensive Fault Diagnosis and Maintenance Guide
  • REXRTOH IndraDrive HMV01 series power supply unit
  • REXRTOH SE 200 Electric Tool Controller Details
  • REXRTOH INDRAMAT RAC 2 Spindle Drive Controller Application Guide
  • REXRTOH CDH1/CGH1/CSH1 series milling machine type hydraulic cylinder
  • REXRTOH MDD Digital AC Servo Motor Application Guide
  • REXRTOH DIAX04 Second Generation Driver Controller Application Guide
  • REXRTOH EcoDrive 03 Drive Controller
  • REXRTOH IndraDrive Controller CS Series Technical Analysis and Application Guide
  • REXRTOH A4VG series 40 axial piston variable displacement pump application guide
  • REXRTOH DDS02.1/03.1 Digital AC Servo Drive
  • REXRTOH VT-HPC Digital Pump Control
  • REXRTOH HNC100-3X Electro hydraulic Motion Control
  • ABB Advant Controller 250 Modular Controller
  • ABB QABP Low Voltage High Efficiency Variable Frequency Motor Application Guide
  • ABB Conductivity Analyzer Application Guide
  • ABB S500 Distributed Remote I/O System
  • ABB AC500 PLC Module Wiring Guide
  • ABB REG216 Digital Generator Protection System
  • Siemens SIRIUS Domestic Control and Protection System
  • Analysis and Application of Siemens SMART LINE V5 HMI Technology
  • SIEMENS CP 5613 A2/CP 5614 A2 Communication Processor
  • SIEMENS SIMOVERT MASTERDRIVES Vector Control Series
  • Siemens 5SN series terminal power distribution products: safe, efficient, and compact electrical solutions
  • Siemens SENTRON 5SY6106-7 miniature circuit breaker
  • Technical Analysis and Application Guide for Siemens SIMATIC TI505/TI500 MODNIM Module
  • Comprehensive Analysis and Configuration Guide for Siemens ET200SP Distributed I/O System
  • Technical Analysis and Application Guide for Siemens EG Frame Molded Case Circuit Breaker NEB/HEB Series
  • Siemens SENTRON 5SY Series Terminal Distribution Products Full Analysis: Innovative Technologies and Application Solutions
  • SIEMENS SIPROTEC 4 System: A Comprehensive Solution for Power Protection and Automation
  • Integration and Application of Siemens SIMO-MM3 Driver Control Block in PCS7 System
  • SINAMICS A10: Intelligent Servo Drive System with Integrated Safety and Efficient Debugging
  • Siemens SITOP UPS 1600/UPS 1100: High reliability DC uninterruptible power supply system for industrial automation
  • Comprehensive Analysis and Selection Guide for Siemens SICAM 8 Substation Automation Platform
  • Siemens SENTRON intelligent circuit protection equipment: full analysis of communication, measurement, and digital management
  • Siemens MOBY I RFID System Configuration and Application Guide
  • SIEMENS S7-1413 Communication Software Architecture and Application Detailed Explanation
  • SIEMENS SINUMERIK System 800 General Interface Technology Explanation and Configuration Guide
  • Siemens SINUMERIK 840C CNC System Installation and Debugging Guide
  • SIEMENS SIMATIC S5-115U Programmable Controller Comprehensive Analysis and Professional Application Guide
  • SIEMENS SIMATIC RF120C Communication Module Comprehensive Analysis and Application Guide
  • Comprehensive analysis and detailed explanation of key technologies for SIEMENS SIMADYN D hardware system
  • Comprehensive Analysis of Siemens TP/OP 170 Series Touch Screen and Operation Panel
  • SIMATIC MODNIM Module Deep Analysis: A Reliable Bridge for Industrial Modbus Communication
  • Comprehensive Analysis and Application Guide for SIEMENS S7-PLCSIM Advanced Simulation Software
  • Technical Analysis and Professional Operation Guide for SIEMENS 1FK6 Servo Motor
  • SIEMENS S7-300 PLC Beginner's Practice: From Hardware Installation to Program Debugging
  • In depth analysis and selection guide for SIEMENS 3AH3 vacuum circuit breaker technology
  • TEKTRONIX MSO5000 and DPO5000 series mixed signal oscilloscope
  • TOSHIBA DI Series Split Air Conditioner
  • TEKTRONIX 5A18N Dual Trace Amplifier
  • Toshiba Discrete IGBTs: Core Architecture, Technological Evolution, and Application Details
  • Foxboro G66 Triconex Tricon Termination Enclosure
  • Triconex Tricon v9-v11 fault-tolerant control system: triple module redundant architecture and high availability design
  • Tricon Triple-Modular Redundant Controller: TMR Architecture for Critical Process Safety
  • Triconex and Pepperl+Fuchs security solutions
  • TRICONEX Trident Controller
  • Woodward EM-80/EM-300 Electric Actuator Specification Guide
  • Woodward EM-80/EM-300 actuator system
  • SCHNEIDER Electric Magelis XBT Series HMI Product Comprehensive Guide and Technical Analysis
  • SCHNEIDER Magelis range Graphic XBT-F / TXBT-F Instruction Manual
  • SCHNEIDER XB2-B Ø 22mm series buttons, selection switches, and indicator lights
  • SCHNEIDER APC Back-UPS Pro Premium battery backup and surge protection for your critical devices
  • SCHNEIDER APC Back UPS Pro Series Uninterruptible Power Supply Complete Usage and Configuration Guide
  • User Guide for SCHNEIDER Service Interface (Part Number LV485500)
  • SCHNEIDER PowerPact ™ H. Modbus Communication User Guide for J and L-type Circuit Breakers
  • SCHNEIDER TeSys D Green series AC/DC universal contactor
  • SCHNEIDER mart series low-voltage distribution products
  • SCHNEIDER TeSys ® GV2/GV3 series motor circuit breakers
  • Schneider Electric ComPacT NSX DC Circuit Breaker Full Solution and Application Guide
  • SCHNEIDER Resi9 The ultimate in residential circuit protection
  • SCHNEIDER Modicon Premium Automation Platform and Unity Software
  • SCHNEIDER Quantum Safety PLC: Complete Analysis of SIL3 Safety Control System