Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TRPAH2A - PRIMARY TRIP AEP
    ❤ Add to collection
  • GE IS200TRPAH2A - PRIMARY TRIP AEP

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200TRPAH2A - PRIMARY TRIP AEP
    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS200TRPAH2A - PRIMARY TRIP AEP

GE IS200TRPAH2A - PRIMARY TRIP AEP

Part Number IS200TRPAH2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TRPAH2A is an Aeroderivative Turbine Primary Trip terminal board developed by GE. Do not inadvertently connect the 240 V ac and dc voltages in 240 V ac applications. The peak voltage will exceed the MOV rating, causing the device to fail. Most ac supplies have a grounded neutral, and if an inadvertent connection between the 125 V dc and the ac voltage is made, the sum of the ac peak voltage and the 125 V dc is applied to MOVs connected between dc and ground. In 120 V ac applications, however, the MOV rating can withstand the peak voltage without failing. 

 IS200TRPAH2A Features As part of the Mark VIe control system, the board interface with PTUR / YTUR I/O packs and TTUR terminal boards. The following are the inputs and outputs:/p> Twelve passive pulse rate devices (four per R/S/T section) measuring turbine speed by sensing a toothed wheel. Alternatively, six active pulse rate inputs (two per TMR section) Two 125 V dc TMR voted output contacts for the trip coil to the main breaker coil. Four 24-125 V dc voltage detection circuits for trip string monitoring One 24-125 V dc 'Fail-safe' ESTOP input for disabling trip relays. Signals from TMR systems fan out to the PR3, PS3, PT3, JR4, JS4, and JT4 connectors. Installation TTL pulse rate pick-ups, voltage detection, E-Stop, and the breaker relay are all connected to I/O terminal block TB1. TB2 is wired with passive pulse rate pick-ups. Each block is held together with two screws and has 24 terminals that accept wires up to #12 AWG. To the left of each terminal block is a shield termination strip connected to chassis ground. 

JP1 and JP2 enable or disable fanning of the R section pulse rate pickups to the S and T PTURs or YTURs. System Design The TRPA board is intended for use in two different ways. When a TRPA terminal board is used to connect three PTUR or YTUR I/O packs to a TTUR terminal board, three cables with DC-37 pin connectors on each end can be used. The TRPA provides two contact-voted trip relay outputs, ESTOP, and four voltage sensors in this mode of operation. TTUR has the standard set of features described for that board. The TRPA speed inputs are inactive and should not be used with this board configuration. The TRPA board can also be used with three I/O packs attached to it directly. The speed inputs to TRPA become active paths into the I/O pack in this mode of operation, allowing for a single terminal board primary trip solution. 

 Trip Relays Trip relays are constructed from groups of six individual form A devices arranged in a voting pattern. A conduction path through the set will be established if two controllers vote to close. Because detecting a shorted relay is critical for maintaining tripping reliability, each set of relays has a sensing circuit installed. When the relays are commanded to open and voltage is applied across the relays, the circuit detects whether one or more relays are shorted. This signal is sent to the I/O pack, which generates an alarm. To avoid a false indication if one I/O pack votes to close the relay while the other two I/O packs vote to open, the TRPA sensing circuit uses relay commands from all three packs. Configuration Jumpers JP1 and JP2 control the fanning of the four passive speed pickups in the R section to the PTURs or YTURs in the S and T sections. To fan the 4 R speed input to the other two TMR sections, place the jumper over the pin pairs.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

Features 

▪ Contains 10 Mbytes of battery-backed user memory and 10 Mbytes of non-volatile flash user  memory. 

▪ Provides access to bulk memory via reference table %W. 

▪ Configurable data and program memory. 

▪ Programming in Ladder Diagram, C, Structured Text, and Function Block Diagram. 

▪ Supports auto-located Symbolic Variables that can use any amount of user memory. 

▪ Reference table sizes include 32Kbits for discrete %I and %Q and up to 32K words each for  analog %AI and %AQ. 

▪ Supports Series 90-70 discrete and analog I/O, communications, and other modules. For a  list of modules supported, refer to the PACSystems RX7i Installation Manual, GFK-2223. 

▪ Supports all VME modules supported by Series 90-70. 

▪ Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server  and FTP connections. 

▪ Supports up to 512 program blocks. Maximum size for a block is 128KB. 

▪ Test Edit mode allows you to easily test modifications to a running program. 

▪ Bit-in-word referencing. 

▪ Battery-backed calendar clock. 

▪ In-system upgradeable firmware. 

▪ Three isolated serial ports: an RS-485 serial port, an RS-232 serial port, and an RS-232  Ethernet station manager serial port. 

▪ The embedded Ethernet interface provides: 

- Data exchange using Ethernet Global Data (EGD) 

- TCP/IP communication services using SRTP 

- Support for SRTP Channels, Modbus/TCP Server, and Modbus/TCP Client 

- Full programming and configuration services 

- Comprehensive station management and diagnostic tools 

- Two full-duplex 10BaseT/100BaseT/TX (RJ-45 Connector) ports with an internal network  switch providing auto-negotiated network speed, duplex mode, and crossover detection. 

- User-configurable Redundant IP address 

- Time synchronization to SNTP time server on Ethernet network (when used with  Release 5.00 or later CPU module).


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide