Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200UCVEH2A UCVE Controller Module
    ❤ Add to collection
  • GE IS200UCVEH2A UCVE Controller Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200UCVEH2A UCVE Controller Module

    • ¥20456.56
      ¥20315.26
      ¥20456.56
      ¥20456.56
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.350KG
    • Quantity:
    • (Inventory: 50)
Description

GE IS200UCVEH2A UCVE Controller Module


GE IS200UCVEH2A UCVE Controller Module

Part Number IS200UCVEH2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200UCVEH2A is a Controller Module developed by GE. It is a part of Mark VI control system. UCVE is housed on a single-slot board, ensuring efficient use of space within the control system setup. It features a 300 MHz Intel Celeron processor, providing adequate processing power for control and monitoring tasks. 

The board is equipped with either 16 or 128 MB of flash memory, offering storage for system firmware and software applications. Additionally, it includes 32 MB of DRAM (Dynamic Random Access Memory), enabling rapid data processing and multitasking capabilities. FEATURES Ethernet Connectivity: Equipped with a single 10BaseT/100BaseTX (RJ-45) Ethernet port, facilitating high-speed connectivity to the Universal Display Hub (UDH). 

This Ethernet port serves as the primary communication interface for data exchange between UCVE and other components within the Mark VI system. Connectivity to UDH: The Ethernet port enables seamless connectivity to the Universal Display Hub (UDH), a central component for system monitoring, configuration, and control. Through the UDH, operators can access real-time data, configure system parameters, and perform diagnostics tasks, enhancing overall system management and performance. Processing and Control Capabilities: With its Intel Celeron processor and memory resources, the UCVE executes control algorithms, logic functions, and other processing tasks essential for system operation. 

It facilitates real-time monitoring of system variables, implements control strategies, and responds to input signals from sensors and other devices to maintain system stability and desired operation. Integration with Mark VI System: It is an integral part of the Mark VI control system, providing the computational power and connectivity required for effective control and monitoring of industrial processes. Its compact form factor and robust design make it suitable for deployment in a wide range of industrial environments, from power generation plants to manufacturing facilities. LED INDICATOR Active LED: Blinking (Active): When the Active LED is blinking, it indicates that the Ethernet connection is active and data transmission is occurring. 

This blinking pattern signifies normal network activity. Solid (Inactive): If the Active LED remains solid without any blinking, it indicates that the Ethernet connection is inactive or not transmitting data. This could imply a network issue or a lack of communication between devices. Link LED: Yellow (10BaseT): The yellow color of the Link LED indicates that the Ethernet connection is operating at a speed of 10BaseT, which corresponds to a data transfer rate of 10 Mbps. This speed is relatively slower and may be suitable for older network setups or devices. Green (100BaseTX): When the Link LED turns green, it signifies that the Ethernet connection is operating at a speed of 100BaseTX, corresponding to a faster data transfer rate of 100 Mbps. 

This speed is more common in modern networks and offers improved performance for data-intensive applications. COM PORTS COM1: Reserved for Diagnostics: COM1 is dedicated for diagnostic purposes. It operates at a baud rate of 9600, with a configuration of 8 data bits, no parity, and 1 stop bit. This port is primarily utilized for diagnostic routines, system monitoring, and troubleshooting tasks, providing essential insights into the device's operational status and performance. COM2: Used for Serial Modbus Communication: COM2 serves as the communication interface for serial Modbus communication. It supports baud rates of either 9600 or 19200, enabling flexible communication configurations based on the specific requirements of the Modbus network. This port facilitates data exchange between the device and external Modbus-compatible devices, such as sensors, controllers, or other industrial equipment.

SPECIFICATIONS:

Part Number: IS200UCVEH2A
Manufacturer: General Electric
Series: Mark VIe
Board Type: UCVE Controller Module
Input Voltage Range: 3.3V to 5V DC
Signal Voltage Levels: TTL/CMOS compatible
Maximum Delay Compensation: Up to 100 ns
Clock Frequency: Up to 200 MHz
Operating Temperature Range: -30°C to +85°C
Dimensions: 25 mm x 25 mm x 5 mm
Mounting Type: Surface-mount technology
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide