    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS215UCVEM02A UCVE Controller Module

    • ¥18542.52
      ¥17252.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.870KG
    • Quantity:
    • (Inventory: 55)
Description

GE IS215UCVEM02A UCVE Controller Module


GE IS215UCVEM02A UCVE Controller Module

Part Number IS215UCVEM02A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS215UCVEM02A is a single-slot board developed by GE. It is a part of Mark VI control system. The board is equipped with secondary 10BaseT/100BaseTX Ethernet ports, providing an additional layer of flexibility and network configuration. This feature allows for the creation of a separate IP logical subnet, enhancing the controller's capabilities in handling diverse networking requirements. 

Configuring the secondary Ethernet port is a straightforward process facilitated through the toolbox, ensuring adaptability to specific operational needs. KEY FEATURES Dual Ethernet Ports: The inclusion of secondary Ethernet ports enables UCVEM modules to accommodate two distinct IP logical subnets. This dual-port functionality enhances network segmentation and provides a mechanism for efficient management of network traffic. Toolbox Configuration: The configuration of the secondary Ethernet port is seamlessly performed through the toolbox interface. This user-friendly configuration tool empowers operators to set parameters such as IP addresses, subnet masks, and other network-related settings, tailoring the module to the specific requirements of the application. 

Validation on Power-Up: Each time the rack housing the UCVEM module is powered up, the controller validates its toolbox configuration against the existing hardware. This validation mechanism ensures that the configured settings align with the physical components, promoting system integrity and preventing potential discrepancies between software and hardware configurations. Separate Subnet Addressing: The allocation of a separate subnet address for the secondary Ethernet port is a pivotal aspect of this feature. This distinct addressing scheme allows the controller to uniquely identify and distinguish each Ethernet port. This separation is particularly beneficial in scenarios where isolation of network segments is necessary, ensuring efficient communication and preventing conflicts between devices. BENEFITS Network Segmentation: The availability of secondary Ethernet ports supports network segmentation, allowing for the creation of isolated communication channels within the system. 

Enhanced Flexibility: The toolbox-driven configuration provides operators with the flexibility to adapt network settings based on changing operational requirements without requiring extensive technical expertise. Prevent Configuration Discrepancies: The validation process during power-up mitigates the risk of configuration errors, ensuring that the toolbox settings align with the physical hardware components. Improved Network Efficiency: With separate subnet addressing, the controller can efficiently manage data flow between different Ethernet ports, optimizing network efficiency and reducing potential bottlenecks. LED INDICATORS Ethernet Status LEDs play a crucial role in providing real-time visual feedback about the operational state and connectivity of an Ethernet interface. 

In the context of the system at hand, there are two main indicators: "Active" and "Link," each with specific characteristics denoted by different colors and blinking patterns. Active LED: The Active LED serves as a dynamic indicator of the current activity status of the Ethernet interface. Its blinking pattern signifies ongoing data transmission and network engagement. When the Active LED is blinking, it signals that the Ethernet interface is actively sending or receiving data, indicating a live and operational connection. On the other hand, a solid illumination of the Active LED suggests that the Ethernet interface is currently inactive, not engaged in any data exchange or communication.

Link LED: The Link LED provides information about the link speed and type of connection established by the Ethernet interface. The color and pattern variations are key indicators of the network's characteristics. Yellow (10BaseT):When the Link LED appears in yellow, it indicates that the Ethernet interface is operating at a 10BaseT speed. This speed corresponds to a data transfer rate of 10 megabits per second, typically suitable for standard network connections. Green (100BaseTX): A green Link LED signifies that the Ethernet interface is operating at a faster 100BaseTX speed. This speed supports data transfer rates of up to 100 megabits per second, providing a higher bandwidth for more demanding network applications.

SPECIFICATIONS:

Part Number: IS215UCVEM02A
Manufacturer: General Electric
Series: Mark VI
Microprocessor: Intel Celeron 300 MHz
Memory: 32 MB DRAM
Operating system: QNX
Programming: Boolean
Product Type: UCVE Controller Module
Voltage Range: 14 to 32 V dc
Maximum Lead Resistance: 15 Ω
Storage temperature: -40 to 80° C
Operating temperature: 0 to 70° C
Technology: Surface mount
Size: 16.2 cm high x 8.6 cm
Repair: 3-7 Day
Availability: In Stock
Weight: 2 lbs
Country of Origin: United States
Manual: GEI-100603A


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide