Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS215VAMBH1A Acoustic Monitoring board
    ❤ Add to collection
  • GE IS215VAMBH1A Acoustic Monitoring board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS215VAMBH1A Acoustic Monitoring board

    • ¥15022.25
      ¥16587.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:8.850KG
    • Quantity:
    • (Inventory: 35)
Description

GE IS215VAMBH1A Acoustic Monitoring board


GE IS215VAMBH1A Acoustic Monitoring board

Part Number IS215VAMBH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockThe IS215VAMBH1A is an acoustic monitoring card assembly module developed by GE under Mark VI series. It has two TAMB boards that provide eighteen channels of signal conditioning and eighteen channels of acoustic monitoring. This board, along with one or two TAMB terminal boards, supports acoustic monitoring for frame 6, 7, or 9 gas turbines. Because of its high impedance DC bias, the board detects open connections between a TAMB board and a charge amplifier. The dc bias control allows for RETx, SIGx, and return line options, as well as 28 V bias or ground applied to the signal line. 

Each channel outputs a buffered BNC signal that is the input signal minus the dc bias. The module consists of a front faceplate, two d-type cable connectors, and three LED board status indicators. Two backplane connectors are situated side by side on the board's rear. Vertical pin connectors are also included on the board. There are numerous integrated circuits on the board. Xilinx field-programmable gate arrays are among them. Two inductor coils are situated between the backplane and the connections. On the board, there are nine 3-pin jumpers. One side is connected to the return signal (RETx), while the middle pin is connected to PCOM. 

 IS215VAMBH1A Installation Current-limited +24 V dc and +24 V dc power supply outputs are provided by each channel. For the PCB sensors, a constant current source is attached to the SIGx line. When the signal is a logic-level low through an output on the VAMB, the input signal, CCSELx, is False. The continuous current output must be deselected until the configuration parameters are loaded, therefore the output must be False (logic-level low) upon power-up. IS215VAMBH1A Operation The VAMB program has the following features: 18 channels of acoustic monitoring Mark VI toolbox for changing configuration constants 40 ms frame rate updates for signal space variables utilized by the application software Offline and online diagnostics to examine the hardware A/D Compensation Any gain or offset mistake caused by initial component variations is eliminated by using the A/D compensation function. 

For the A/Ds it controls, the firmware has an auto-calibration capability. Each of the 18 analog channels is compared to a gold standard A/D channel in the auto-calibration feature. A standard high-precision voltage reference and the A/D common are used to calibrate the gold standard A/D channel. A/D Gain Adjust The channel gain in the hardware is controlled by the configuration parameter Gain defined for each channel. This enables the amplification of low-level signals in the analog to digital conversion gear to improve resolution. There are four gain options: 1, 2, 4, and 8. 

The gain setup is written to the FPGA VSPA input amplifier 4x and 2x gain control registers via the channel control. Because the signal is divided by the gain factor in the firmware to result in a net gain of 1 for the signal regardless of the gain factor used, the signal level estimated by the VAMB firmware will not change with a change in the Gain parameter. Diagnostics The state of the VAMB front panel is indicated by three LEDs at the top. The RUN state is flashing green, whereas the FAIL condition is a solid red. 

The third LED is generally off, but if the board has a diagnostic alarm, it will display a continuous orange. Each input has two customizable degrees of system limit checking. These limits can be set to enable/disable,> = or =, latching/non-latching, and latching/non-latching. The out-of-limits are reset with RESET SYS. If this limit is exceeded, a signal is generated by the system limit logic.

The IS215VAMBH1A is an acoustic monitoring card assembly module developed by GE under Mark VI series. It has two TAMB boards that provide eighteen channels of signal conditioning and eighteen channels of acoustic monitoring. This board, along with one or two TAMB terminal boards, supports acoustic monitoring for frame 6, 7, or 9 gas turbines.

Because of its high impedance DC bias, the board detects open connections between a TAMB board and a charge amplifier. The dc bias control allows for RETx, SIGx, and return line options, as well as 28 V bias or ground applied to the signal line. Each channel outputs a buffered BNC signal that is the input signal minus the dc bias.

The module consists of a front faceplate, two d-type cable connectors, and three LED board status indicators.

Two backplane connectors are situated side by side on the board's rear. Vertical pin connectors are also included on the board. There are numerous integrated circuits on the board. Xilinx field-programmable gate arrays are among them. Two inductor coils are situated between the backplane and the connections.

On the board, there are nine 3-pin jumpers. One side is connected to the return signal (RETx), while the middle pin is connected to PCOM.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration