Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • KISTLER 4734AWDY2X400S1 Force Displacement Indicator
    ❤ Add to collection
  • KISTLER 4734AWDY2X400S1 Force Displacement Indicator

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥41364.00
      ¥42634.00
      ¥41364.00
      ¥41364.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:14.340KG
    • Quantity:
    • (Inventory: 5346)
Description
<span style="font-size: 18px; font-family: arial;">KISTLER 4734AWDY2X400S1 Force Displacement Indicator</span>

KISTLER 4734AWDY2X400S1: DMF-P A300 Force and Displacement Value Display Unit

Product Overview

The KISTLER 4734AWDY2X400S1 is a force and displacement value display unit from the DMF-P A300 series, designed for dynamic measurement applications requiring high precision signal conditioning and visualization. This device serves as a dedicated indicator and signal processor for Kistler piezoelectric sensors, including force sensors, pressure transducers, torque sensors, and acceleration sensors. It integrates PiezoSmart technology, which automatically configures the unit to match the characteristics of the connected sensor, simplifying setup and calibration. The DMF-P A300 is suitable for industrial automation, quality assurance testing, and research and development environments where real time display and monitoring of dynamic physical quantities is required.


Key Features of KISTLER 4734AWDY2X400S1

The device incorporates Kistler PiezoSmart intelligent sensor technology, which enables automatic detection and configuration of connected PiezoSmart compatible sensors. This eliminates manual entry of sensitivity values and reduces setup time. The unit provides real time numerical display of measured values for force, displacement, pressure, torque, or acceleration, depending on the attached sensor type. It is designed for high dynamic response, capturing rapidly changing process values without signal attenuation or phase shift. The robust industrial housing protects the internal electronics from dust and moisture in manufacturing environments. The DMF-P A300 series units are engineered to operate with the full range of Kistler charge amplifiers and piezoelectric sensors, providing a complete measurement chain from sensor to display.

Technical Specifications

  • Manufacturer: Kistler Group

  • Part Number: 4734AWDY2X400S1

  • Series: DMF-P A300

  • Product Type: Force and displacement value display unit

  • Measurement Functions: Force, displacement, pressure, torque, acceleration

  • Sensor Technology: PiezoSmart compatible

  • Display Type: Digital numerical display

  • Signal Processing: Dynamic measurement with high frequency response

  • Mounting: Panel mount or DIN rail

  • Compatible Sensors: Kistler piezoelectric force, pressure, torque, and acceleration sensors

Functional Description

The 4734AWDY2X400S1 receives charge or voltage signals from a connected piezoelectric sensor, amplifies and conditions the signal, and converts it to a digital reading displayed on the front panel. When used with PiezoSmart enabled sensors, the unit automatically reads sensor identification and calibration data from an integrated memory chip in the sensor cable connector. This automation ensures that the correct measurement range and scaling factors are applied without operator intervention. The device supports multiple measurement modes including peak hold, valley hold, and continuous tracking, allowing users to capture maximum and minimum values during a measurement cycle for quality analysis.

Applications

This force and displacement indicator is deployed in industrial production and testing applications where dynamic force or displacement monitoring is required. Typical uses include press fit monitoring in assembly operations, force controlled fastening systems, material testing machines, and impact force measurement in drop test equipment. In research and development settings, the DMF-P A300 is used with Kistler dynamometers for cutting force measurement in machining studies, and with pressure sensors for engine combustion analysis. The device provides a compact, dedicated display solution for systems that do not require full PC based data acquisition, offering simplicity and reliability in production environments.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide