Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • LUST LTI DRIVES CDE34.010 Variable Frequency Drive
    ❤ Add to collection
  • LUST LTI DRIVES CDE34.010 Variable Frequency Drive

    • ¥23122.00
      ¥23442.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.620KG
    • Quantity:
    • (Inventory: 23)
Description
<span style="font-size: 18px; font-family: arial;">LUST LTI DRIVES CDE34.010 Variable Frequency Drive</span>

LUST LTI DRIVES CDE34.010 Variable Frequency Drive

The LUST LTI DRIVES CDE34.010 is a variable frequency drive designed for industrial motor control. With a rated capacity of 6.9 kVA, it provides adjustable speed and torque control for three-phase AC motors. The drive is part of the CDE34 series, which is known for robust construction and reliable operation in demanding automation environments. It is suitable for applications requiring energy-efficient motor regulation, smooth acceleration, and precise process control.

Series Overview

The CDE34 family is part of the LUST LTI DRIVES portfolio, which includes drive controllers, frequency inverters, and motion control components. The CDE34.010 model is identified by its power rating and hardware configuration. The additional designation D2.4 refers to a specific version or option set. This drive is designed for cabinet mounting and can be integrated into larger drive systems with common power supply and communication architecture.

Power and Performance

The 6.9 kVA rating indicates the drive capacity for continuous motor operation. The drive converts a DC bus voltage or an AC supply into a controlled output for the motor. It supports variable frequency and voltage control, which allows the motor speed to be adjusted according to process requirements. The drive can provide high starting torque and smooth acceleration, which is important for conveyors, mixers, pumps, and fans.

Control Methods

The CDE34.010 supports different control methods, including linear voltage frequency control and sensorless vector control. These methods allow the drive to match the motor characteristics and the load profile. Parameter sets can be configured for different motors and applications. The drive can also be used in closed-loop operation with a feedback device when higher speed or torque accuracy is required.

Input and Output Interfaces

The drive includes digital inputs for start, stop, and direction commands. Analog inputs can be used for speed or torque reference. Relay outputs and digital outputs provide status and fault signals. Communication options may include serial interfaces or fieldbus modules, depending on the configuration. These interfaces allow the drive to be controlled by PLCs, motion controllers, or higher-level automation systems.


Protection Functions

The CDE34.010 includes protection against overcurrent, overvoltage, undervoltage, overtemperature, and short circuit. It also monitors motor overload and ground fault conditions. When a fault occurs, the drive shuts down according to configured parameters and provides diagnostic information. This helps protect the motor, the drive, and the connected machinery from damage.

Thermal Management and Installation

Proper thermal management is essential for reliable operation. The drive should be mounted in a well-ventilated cabinet with sufficient clearance for air circulation. Ambient temperature and humidity must remain within specified limits. Power cables should be shielded and grounded according to EMC guidelines. Motor cables should be kept as short as possible to reduce losses and interference.

Commissioning and Software

Commissioning is supported by LUST LTI DRIVES engineering software. Users can set motor parameters, configure inputs and outputs, and tune control loops. The software provides diagnostic tools and trace functions for analyzing drive behavior. Parameter sets can be saved and reused, which simplifies commissioning and maintenance. Firmware updates may be applied to improve functionality.


Applications

The CDE34.010 is suitable for a wide range of industrial applications. It can be used in pumps, fans, conveyors, mixers, extruders, and winding machines. It is also suitable for process lines where speed and torque must be controlled accurately. The 6.9 kVA rating makes it appropriate for medium-power motors in continuous or intermittent duty. The drive can be integrated into multi-drive systems with common DC bus and braking units.

Energy Efficiency

Variable frequency drives can significantly reduce energy consumption in applications with variable flow or pressure requirements. By adjusting motor speed to match demand, the drive avoids the losses associated with throttling or mechanical speed control. The CDE34.010 supports this energy-saving approach while maintaining process stability and motor protection.

Maintenance and Service

The drive requires minimal maintenance under normal conditions. Periodic inspection of cooling fans, filters, and connections is recommended. Dust and moisture should be kept out of the cabinet. Parameter backups should be maintained for service. If the drive is replaced, the same firmware and parameter set should be used to ensure compatibility with the existing system.

Selection Considerations

When selecting the CDE34.010, users should verify the motor power, current, voltage, and duty cycle. The drive must be matched to the motor and load to ensure stable operation. The D2.4 option should be checked against the machine specification. In multi-drive systems, the power supply, braking, and communication architecture must be coordinated.

Conclusion

The LUST LTI DRIVES CDE34.010 is a reliable variable frequency drive with a 6.9 kVA rating. It offers flexible control methods, robust protection, and integration options for industrial motor applications. With correct selection and commissioning, it supports efficient and stable machine operation.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide
  • Bosch Rexroth VT-MSPA Proportional Valve Amplifier Configuration and Troubleshooting Guide
  • Bosch Rexroth CDH1/CGH1/CSH1 Square Cylinder Selection and Compression Rod Verification
  • Bosch Rexroth CD/CG/CS Hydraulic Cylinder Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide
  • Bosch Rexroth MSK Servo Motor Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth IndraMotion MTX CNC System Selection and Backup Guide
  • GE MV3000 Inverter Cooling Fan Replacement and Upgrade Plan
  • Bosch Rexroth Indramat DIAX04 HDD/HDS Drive Controller Planning Guide
  • Technical Analysis and Selection Guide for Bosch Rexroth AZPF Gear Pump
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller