  • NI CFP-AO-210 Analog Output Module
    ❤ Add to collection
  • NI CFP-AO-210 Analog Output Module

    NI CFP-AO-210 Analog Output Module

    • ¥23500.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.600KG
    • Quantity:
    • (Inventory: 35)
Description

NI CFP-AO-210 Analog Output Module


NI CFP-AO-210 Analog Output Module

DESCRIPTION

These operating instructions describe how to install and use the National Instruments FP-AO-210 and cFP-AO-210 analog output modules (referred to inclusively as the [c]FP-AO-210). For information about configuring and accessing the [c]FP-AO-210 over a network, refer to the user manual for the FieldPoint network module you are using.

Features

The [c]FP-AO-210 is a FieldPoint analog output module with the following features:

• Eight 0–10 V outputs 

• 12-bit resolution 

• Sources 1 mA per channel (up to 10 mA with optional external power supply) 

• Overcurrent indicators 

• 2,300 Vrms transient overvoltage protection between the inter-module communication bus and the I/O channels 

• –40 to 70 °C operation 

• Hot plug-and-play

Installing the cFP-AO-210

The cFP-AO-210 mounts on a Compact FieldPoint backplane (cFP-BP-x). Hot plug-and-play enables you to install the cFP-AO-210 onto a powered backplane without disturbing the operation of other modules or connector blocks. The cFP-AO-210 receives operating power from the backplane.

Voltage Output Circuit

The [c]FP-AO-210 output circuit is a current-limited voltage source capable of sourcing (flowing out of the Vout terminal to the load) or sinking (flowing into the Vout terminal from the load) current. The [c]FP-AO-210 internal circuitry limits the magnitude of this current to 1 mA. You can obtain up to 10 mA sourcing current by adding an optional external power supply. The [c]FP-AO-210 operates with an external power supply from 15 to 30 VDC.

The [c]FP-AO-210 updates the output channels as new values are sent to it by the network module. The time it takes to respond to a change on a single channel is between 3 and 6 ms. The response time to changes on all eight channels is 24 to 27 ms.

Output Range

The [c]FP-AO-210 has an output range of 0–10 V. The factory default power-up setting for each channel is 0 V. The [c]FP-AO-210 has overranging of 0.2 V. Therefore, the actual full-scale range of each channel is 0–10.2 V. This extended range enables the [c]FP-AO-210 to compensate for span and offset errors in field devices.

Current Limit Detection

Each channel on the [c]FP-AO-210 has a monitoring circuit that detects the amount of current flowing into (sinking) or out of (sourcing) the channel. If this value exceeds the maximum allowable (1 mA with no external supply; 10 mA with external supply), the circuit lights a red STATUS indicator for each affected channel, reports the error to the network module, and adjusts the output voltage so that only the maximum allowed current flows. The error is reported before the output is adjusted. The indicator may start to light dimly as the limit is approached.

Overvoltage Protection

Each [c]FP-AO-210 output terminal Vout is protected against damage resulting from accidental connection to the output terminals of other channels. Also, you can connect one or more channel output terminals directly to an external voltage source indefinitely without causing damage or improper operation of other channels, as long as the maximum voltage does not exceed the range of –10 to 20 VDC referenced to the C and COM terminals.

Specifications

Power Requirements

Power from network module ............600 mW

Isolation Voltage

Channel-to-channel isolation............No isolation between channels

Transient overvoltage........................2,300 Vrms

Environmental

Operating temperature ......................–40 to 70 °C

Storage temperature..........................–55 to 100 °C

Humidity ...........................................10 to 90% RH, noncondensing

Maximum altitude.............................2,000 m

Pollution Degree ...............................2


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard