Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Palmscan P2000 FP Pachymeter
    ❤ Add to collection
  • Palmscan P2000 FP Pachymeter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥15284.00
      ¥16217.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.800KG
    • Quantity:
    • (Inventory: 83)
Description
<span style="font-size: 18px; font-family: arial;">Palmscan P2000 FP Pachymeter</span>

Palmscan P2000 FP Pachymeter

The Palmscan P2000 FP is a pachymeter designed for corneal thickness measurement in ophthalmic practice. It is associated with Micro Medical Devices and the Fastpach measurement concept. The device provides quick and reliable readings that support clinical assessment of the cornea before and after surgical procedures.

Corneal thickness is an important parameter in ophthalmology. It is used in the evaluation of glaucoma risk, in pre operative planning for refractive surgery, and in the monitoring of corneal health. The P2000 FP is built to deliver consistent measurements in a clinical setting, helping practitioners make informed decisions.

Product Overview

The P2000 FP is a compact handheld or tabletop pachymeter that uses ultrasound technology to measure corneal thickness. A small probe is placed against the cornea, and the device calculates the distance between the anterior and posterior surfaces. The result is displayed clearly on the screen and can be recorded for the patient file.

The device is designed for ease of use. Its interface guides the operator through the measurement process, and the probe is shaped for comfortable contact with the eye. The measurement is fast, which helps reduce patient discomfort and improves workflow in busy clinics.

Key Features

  • Pachymeter for corneal thickness measurement

  • Fast and reliable readings for clinical use

  • Clear display of measurement results

  • Ergonomic probe for patient comfort

  • Compact design for clinic and surgical environments

  • Associated with Micro Medical Devices and Fastpach technology

  • Supports pre operative and post operative assessment

  • Identified by model P2000 FP


Measurement Principle

The pachymeter uses ultrasound to measure corneal thickness. The probe emits a high frequency pulse that travels through the cornea and reflects from the posterior surface. The time taken for the echo to return is used to calculate the thickness. This method is well established in ophthalmology and provides repeatable results when the probe is correctly positioned.

The P2000 FP is designed to give stable readings even when the operator is working quickly. The display shows the measured value in micrometres, which is the standard unit for corneal thickness. Multiple readings can be taken and compared to ensure consistency.

Applications

The device is used in glaucoma clinics, refractive surgery centres, and general ophthalmology practices. It supports the assessment of corneal thickness before laser vision correction, where accurate measurement is important for safe treatment planning. It is also used to monitor the cornea after surgery and in the follow up of patients with corneal disease.

Because the measurement is quick and non invasive, the P2000 FP is suitable for routine examinations as well as for more detailed diagnostic work.

Clinical Workflow

In a typical workflow, the patient is seated and asked to look straight ahead. The operator applies a small amount of coupling medium to the probe and gently places it against the cornea. The device takes the measurement and displays the result. The operator can repeat the measurement to confirm the value and then record it in the patient file.

The P2000 FP is designed to fit into existing clinical routines without requiring extensive training. Its controls are straightforward, and the display is easy to read in different lighting conditions.

Maintenance and Care

Proper care of the probe and the device helps maintain measurement accuracy. The probe tip should be cleaned according to the manufacturer instructions after each use. The device should be stored in a clean, dry place and protected from impact. Regular calibration checks help ensure that readings remain within specification.

Why Choose the Palmscan P2000 FP

The Palmscan P2000 FP provides fast, reliable corneal thickness measurement in a practical and easy to use package. Its association with Micro Medical Devices and Fastpach technology, combined with its clear display and ergonomic probe, makes it a useful tool for ophthalmic assessment.


Frequently Asked Questions

What is the P2000 FP used for?

It is used to measure corneal thickness in ophthalmic examinations.

What technology does it use?

It uses ultrasound to measure the cornea.

Where is it used?

It is used in glaucoma clinics, refractive surgery centres, and general ophthalmology.

Is the measurement quick?

Yes, the device is designed to provide fast readings for clinical workflow.

Conclusion

The Palmscan P2000 FP pachymeter supports accurate corneal measurement in clinical practice. Its fast readings, clear display, and ergonomic design make it a practical choice for ophthalmologists and eye care professionals.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide
  • Bosch Rexroth VT-MSPA Proportional Valve Amplifier Configuration and Troubleshooting Guide
  • Bosch Rexroth CDH1/CGH1/CSH1 Square Cylinder Selection and Compression Rod Verification
  • Bosch Rexroth CD/CG/CS Hydraulic Cylinder Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide
  • Bosch Rexroth MSK Servo Motor Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth IndraMotion MTX CNC System Selection and Backup Guide
  • GE MV3000 Inverter Cooling Fan Replacement and Upgrade Plan
  • Bosch Rexroth Indramat DIAX04 HDD/HDS Drive Controller Planning Guide
  • Technical Analysis and Selection Guide for Bosch Rexroth AZPF Gear Pump
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller