Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • SND ATS48D38Q Soft Starter
    ❤ Add to collection
  • SND ATS48D38Q Soft Starter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥43534.00
      ¥46364.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.440KG
    • Quantity:
    • (Inventory: 4355)
Description
<span style="font-size: 18px; font-family: arial;">SND ATS48D38Q Soft Starter</span>

SND ATS48D38Q Soft Starter (Torque Control)

The SND ATS48D38Q is a microprocessor-controlled soft starter designed to reduce mechanical stress and electrical inrush currents in three-phase induction motors. It uses patented torque control technology to provide smooth acceleration and deceleration, extending the life of motors and driven equipment.

Main Specifications

  • Rated current (standard): 38 A (10-minute overload 46 A)

  • Motor power (230V): 11 kW; (400V): 22 kW; (460V): 30 HP

  • Supply voltage: 208–690 V AC, 50/60 Hz

  • Control supply: 110–230 V AC internal

  • Number of start cycles: Up to 6 per hour (heavy duty), 20 per hour (light duty)

  • Integrated bypass: Yes (thyristor bypass)


Torque Control System (TCS)

Unlike conventional voltage ramp soft starters, the ATS48D38Q controls motor torque directly, compensating for load variations. This results in linear acceleration regardless of load inertia, preventing belt slip or gear shock. The deceleration control avoids water hammer in pumping systems.

Protection Functions

The unit includes motor thermal protection (I²t), phase loss, phase unbalance, overcurrent, short-circuit on SCR, and stall protection. It also monitors heatsink temperature and provides alarms via a configurable relay output. All protection thresholds are adjustable via the keypad.

User Interface and Setup

A backlit graphic display shows motor current, thermal state, and diagnostic messages. Setup is guided by a simple menu with parameters grouped logically. Advanced settings include kickstart for high-friction loads, dual ramp for two-speed applications, and pump cleaning function.

Communication and Integration

The ATS48D38Q comes with MODBUS serial communication as standard. Optional fieldbus modules (PROFIBUS DP, DeviceNet, Ethernet/IP) are available. It also features three programmable logic inputs and two relay outputs for remote monitoring and control.

Typical Applications

This soft starter excels in pumps, fans, compressors, conveyors, crushers, and centrifugal machines. Its bypass design reduces heat dissipation after startup, allowing installation in smaller cabinets without active cooling.

Certifications

CE, UL, cUL, CCC, and GOST certified. Meets EMC standards (IEC 60947-4-2). Environmental rating IP20 (NEMA 1). Operating temperature -10°C to +40°C without derating.

Conclusion

The SND ATS48D38Q combines rugged construction, precise torque control, and extensive protection features. It is a reliable solution for applications demanding smooth starts and stops while minimizing electrical stress on the power system.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card