AB 1756-IR6I ControlLogix Analog I/O Modules

来源: | 作者:FAN | 发布时间 :2025-04-17 | 545 次浏览: | Share:

AB 1756-IR6I ControlLogix Analog I/O Modules

Module Basic Information

Function Introduction: 1756 - IR6I, 1756 - IT6I, 1756 - IT6I2 These three modules are designed for temperature measurement. The 1756 - IR6I converts temperature by measuring resistance values, while the 1756 - IT6I and 1756 - IT6I2 measure temperature based on millivolt signals. They are able to linearise the analogue signals collected by the sensors into precise temperature values and are widely used in industrial temperature monitoring and control.

Data format selection: Two data formats are available: integer mode and floating point mode. Integer mode supports multiple input ranges, trap filters, real-time sampling, etc. Cold-side temperature measurement is only available on the 1756-IT6I and 1756-IT6I2 modules, but temperature linearisation, process alarms, digital filtering and rate alarms are not supported. Floating point mode has all features. The user must carefully select the appropriate data format for the application, e.g. for data processing accuracy and functionality.


Module Characteristics

Input Range and Signal Processing: Each module supports a variety of input ranges, including 1...487Ω, 2...1000Ω for 1756-IR6I, -12...78mV, -12...30mV for 1756-IT6I and 1756-IT6I2, and -12...30mV for 1756-IT6I and 1756-IT6I2, and -12...30mV for 1756-IT6I and 1756-IT6I2. ...30mV. A trap filter removes line noise from the application and can be set to 10Hz, 50Hz, 60Hz (default) depending on the expected noise frequency. The real-time sampling function enables the module to scan the input channel according to the specified real-time sampling (RTS) period and multicast the data after scanning, and the request packet interval (RPI) period can also be set.


Detection and Alarm Functions: Under-range/over-range detection function allows real-time monitoring of whether the input signal is out of the set range. Digital filters are available in floating-point mode to smooth the input data by setting the time constant, effectively reducing noise interference. Process alarm and rate alarm are also supported only in floating point mode. Users can configure four alarm trigger points, namely high, high - high, low, low - low, and alarm deadband according to their needs, and the rate alarm will be triggered when the rate of change of the input signal exceeds the set threshold.


Other functions: 10Ω offset function is used to compensate the small offset error of 10Ω copper RTD, the compensation range is - 0.99...0.99Ω. The module is equipped with a line break detection function, when a line break is detected, the input data of the corresponding channel will be changed to a specific scaled value and the fault bit will be set in the controller. Multiple sensor types are supported. The 1756-IR6I can be configured with a variety of RTD sensors, including 10Ω - Copper Type 427, and the 1756-IT6I and 1756-IT6I2 support a variety of thermocouples, including B, E, and J. The modules are available in Celsius and Celsius. The modules are available in both Celsius and Fahrenheit temperature units.


Module Differences: The 1756-IT6I2 has significant advantages over the 1756-IT6I. In terms of sensor type support, the 1756-IT6I2 supports two additional thermocouple types, D and TXK/XK(L). For cold-end compensation, the 1756-IT6I2 uses two cold-end sensors, limiting cold-end error to ±0.3°C (0.54°F), while the 1756-IT6I uses a single cold-end sensor with a maximum error of ±3.2°C (5.76°F). In terms of module accuracy, the 1756-IT6I2 also has better gain drift and temperature range error specifications of 25ppm and 0.15%, respectively, compared to 80ppm and 0.5% for the 1756-IT6I.


Module Wiring and Use

Wiring: Detailed wiring diagrams and examples are provided. 1756-IR6I modules support both 3-wire and 4-wire RTD wiring. care should be taken not to connect more than two wires to a single terminal, and not to exceed specific isolation voltages if a separate power supply is used. 1756-IT6I and 1756-IT6I2 modules are wired accordingly and 1756-IT6I2 requires two wires to be connected when using RTB. The 1756 - IT6I and 1756 - IT6I2 modules are also wired accordingly, and the 1756 - IT6I2 requires the connection of two cold sensors when using RTB.


Module Configuration and Fault Reporting: Module block diagrams and input circuit diagrams provide an in-depth understanding of the internal circuitry of the module and assist in module configuration and troubleshooting. Fault and status reports are divided into floating-point mode and integer mode, providing detailed fault information through three levels of labels: module fault word, channel fault word and channel status word. The two modes differ in what and how faults are reported. For example, in integer mode, the channel status word only reports under- and over-range conditions, not alarm and calibration fault activity.


Technical Support and Resources: Rockwell Automation provides a wealth of technical support resources. Technical and application notes, sample codes, and links to software service packs are available through the official website. The Support Centre provides software updates, technical information, FAQs, and access to support chats and forums. A variety of support plans are available for installation, configuration, and troubleshooting. In the event of product problems, users can contact their reseller or customer service, depending on their region, and provide feedback on documentation improvements.

  • YASKAWA NPSO-0503L high-precision servo drive module
  • YASKAWA LASC-100SUB high-precision motion control module
  • YASKAWA JUSP-WS15AB servo control unit
  • YASKAWA JANCD-MIF01 Multi Interface Communication Card
  • YASKAWA JAMSC-B1063 Industrial Control Module
  • YASKAWA JAMSC-B1050 Industrial Control Module
  • Alstom BCSR1 TERMINAL BOARD OF 8 LOGIC OUTPUT SIGNALS
  • Alstom BCEA1 TERMINAL BOARD OF 8 ANALOGUE INPUT SIGNALS
  • Alstom BCEL2 TERMINAL BOARD FOR 12 LOGIC INPUT SIGNALS
  • Alstom E64L1- LOGIC INFORMATION ACQUISITION BOARD
  • Alstom FRTN2 BOARD OF DIGITAL INDICATION OF VOLTAGE REGULATION
  • Alstom ARTN1 DIGITAL INDICATION BOARD FOR VOLTAGE REGULATION
  • Alstom MCRI1 MODULE BOARD FOR SETTING SETTINGS AND CURRENT REGULATION
  • Alstom CPRM1 SINGLE-PHASE POWER REGULATION BOARD
  • Alstom ESVI1 INPUT/OUTPUT BOARD FOR CURRENT AND VOLTAGE SIGNALS
  • Alstom RDSP1 BOARD FOR ADJUSTING DIGITAL SIGNAL PROCESSES
  • Alstom MDEX1 microprocessor control board
  • Alstom IRVI20 - REGULATION INTERFACE BOARD
  • Alstom AMS42 POWER SUPPLY BOARD
  • ABB VACUUM CONTACTOR VSC7 SCO IEC 60470 400A 3POLE 220-250V 50/60Hz
  • ABB DRIVEMONITOR VERSION 4000 DRIVE MODULE RBOX316-ABB-00
  • YASKAWA JACP-317802 AC servo drive
  • YASKAWA JACP-317801 Advanced Process Controller
  • YASKAWA JACP-317120 Power Supply Unit
  • YASKAWA CP-9200SH/SVA servo controller
  • YASKAWA CP-9200SH/CPU Programmable Controller
  • YASKAWA CP-317/DO-01 Digital Output Module
  • YASKAWA CP-317/218IF high-speed communication interface module
  • YASKAWA CP-317/217 IF Communication Interface Module
  • YASKAWA CIMR-M5D2018 High Performance Inverter
  • YASKAWA CACR-HR10BB servo drive
  • YASKAWA 218IF machine controller
  • YOKOGAWA YS1700-100/A06/A31 Programmable Indicator Controller
  • YOKOGAWA KS9-5 * A signal cable
  • YOKOGAWA KS8-5 * A signal cable
  • YOKOGAWA KS2-5 * A DSC signal cable
  • YOKOGAWA PW482-10 power module
  • YOKOGAWA SCP451-11 processor module
  • YOKOGAWA SR1030B62-3MN * 1C High Frequency Signal Processor
  • YOKOGAWA SR1030B62 Analog Input Module
  • YOKOGAWA CP451-10 processor module
  • YOKOGAWA CP451-50 processor module
  • YOKOGAWA AAI143-H50 Analog Input Module
  • YOKOGAWA 22.5 × 17.4 × 10 Compact Industrial Control Module
  • YOKOGAWA AMM42 multiplexer input module
  • YOKOGAWA SDV144-S63 Digital Input Module
  • YOKOGAWA AIP830-111 single player keyboard
  • YOKOGAWA S9361DH-00 Terminal Board Module
  • YOKOGAWA ATK4A-00 S1 KS Cable Interface Adapter
  • YOKOGAWA PW701 power module
  • YOKOGAWA AVR10D-A22010 Duplex V-net Router
  • YOKOGAWA PW441-10 power module
  • YOKOGAWA VI451-10 Communication Interface Module
  • YOKOGAWA VC401-10 Coupling Module
  • YOKOGAWA ALP121 Communication Module
  • YOKOGAWA NFAI841-S00 Analog Input Module
  • YOKOGAWA AIP591 Process Control Module
  • YOKOGAWA AIP578 optical link transceiver
  • YOKOGAWA PW501 power module
  • YOKOGAWA YNT511D fiber optic bus repeater
  • YOKOGAWA AIP171 transceiver control module
  • YOKOGAWA VI702 Vnet/IP Interface Card
  • YOKOGAWA 2302-32-VLE-2 electronic mixer
  • YOKOGAWA ATK4A-00 Cable Interface Adapter
  • YOKOGAWA ALR121-S00 Communication Module
  • YOKOGAWA CP461-50 processor module
  • YOKOGAWA AIP121-S00 Control Module
  • YOKOGAWA UR1800 Recorder
  • YOKOGAWA LC82 * A Industrial Controller
  • YOKOGAWA ANR10D bus node unit
  • YOKOGAWA SDV144-S13 Digital Input Module
  • YOKOGAWA NFAI143-H00 Analog Input Module
  • YOKOGAWA EB501 Bus Interface Module
  • YOKOGAWA CP451-10 Process Control Module
  • YOKOGAWA V0/E1/TCAM/L08 Advanced Process Control Module
  • YOKOGAWA VO/E2/TCDM24/L8 high-precision temperature control module
  • YOKOGAWA 16137-119 high-precision digital input module
  • YOKOGAWA 16114-500 module rack
  • YOKOGAWA PSCDM024DCBAN Key Discrete Module
  • YOKOGAWA 16137-151 Process Control Module
  • YOKOGAWA 16137-188 Process Control Module
  • YOKOGAWA 16137-222 Process Controller
  • YOKOGAWA 16137-223 high-precision temperature transmitter
  • YOKOGAWA 16137-153 Digital Input Module
  • YOKOGAWA 866257000 high-precision temperature controller
  • YOKOGAWA 8596020000 Digital I/O Module
  • YOKOGAWA 866256000 high-precision process control module
  • ABB AFS670 19" Ruggedized Switch AFS670-EREEDDDSSEEEEEEEPZYX05.1.0
  • NI VXIpc-871B Controller
  • YOKOGAWA PSCAMAAN Process Control Analog Input Module
  • YOKOGAWA DR1030B60 servo actuator
  • YOKOGAWA ADV551 Digital Output Module
  • YOKOGAWA AAI543 proposed output module
  • YOKOGAWA LR 4220E Level Transmitter
  • YOKOGAWA SR1008B62 External Wiring Module
  • YOKOGAWA SC200S Control Valve Positioner
  • YOKOGAWA PW301 power module
  • YOKOGAWA NP53 * C Precision Control Module
  • YOKOGAWA F3YD64-1A transistor output module
  • YOKOGAWA F3XD64-3N Industrial Module Controller
  • YOKOGAWA F3WD64-3N High Performance Module Controller
  • YOKOGAWA F3SP21-0N CPU module
  • YOKOGAWA F3PU10-0N AC power module
  • YOKOGAWA F3PU06-0N power module
  • YOKOGAWA F3NC02-0N positioning module
  • YOKOGAWA F3NC01-0N positioning module
  • YOKOGAWA F3LC21-1N Multi Link Module
  • YOKOGAWA F3BU06-0N Base Module
  • FORCE PMC234 control module
  • FORCE CPU-2CE/16 Industrial Control CPU Module
  • Foxboro PBCO-D8-010 FBM I/O cards
  • FOXBORO PBCO-D8-009 Digital Output Module
  • FOXBORO FBM207C RH917GY High Density Contact Induction Input Module
  • FOXBORO AD916AE Digital Control System Module
  • FOXBORO FBM217 discrete input module
  • FOXBORO RH926GH processor module
  • FOXBORO H90 H90C9AA0117S Differential Pressure Transmitter
  • FOXBORO P0926GJ high-precision differential pressure transmitter
  • FOXBORO RH928AW control module
  • FOXBORO N-2AX+DIO signal distribution module
  • FOXBORO RH924WA Fiber Optic Network Adapter
  • FOXBORO P0924JH Control System Module
  • FOXBORO H92 Process Automation System
  • FOXBORO PP0926KN control module
  • FOXBORO P0916FH controller
  • FOXBORO E69F-T-I2-JRS on-site installation signal converter
  • FOXBORO P0926JM Standard 200 Series Baseplates
  • FOXBORO E69F-BI2-S Current Pneumatic Signal Converter