Electromagnetic compatibility: It has certain electromagnetic compatibility, such as ESD (electrostatic discharge) immunity of 6 kV contact discharge and 8 kV air discharge; Radiated RF immunity has different requirements in different frequency ranges, such as 10V/m with 1 kHz sine - wave 80% AM from 80 - 2000 MHz, etc; EFT/B immunity is ±4 kV at 5 kHz at power and communication ports; Surge transient immunity has different tolerance values at different ports, e.g. ±1 kV line - line (DM) and ±2 kV line - earth (CM) at power port, etc.; Conducted RF Immunity is 10V rms with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz. These parameters ensure that the device can work properly in complex electromagnetic environments without causing interference to other devices.
Approvals: Several approvals have been obtained, including UL (UL Listed Industrial Control Equipment), CSA (CSA Certified Process Control Equipment, etc.), FM (FM Approved Equipment for use in), FM (FM Approved Equipment for use in), and FM (FM Approved Equipment for use in). FM (FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations), CE (European Union 2004/108/EC EMC Directive etc.), C-Tick (Australian Radiocommunications Act), Ex (European Union 94/9/EC ATEX Directive) and CI (ControlNet Int'l conformance tested to ControlNet specifications). These certifications indicate that the equipment complies with relevant safety, quality and industry standards and is safe for use in the respective regions and environments.