Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

WAGO 221 series LEVER-NUTS ® Compact splicing connector

F: | Au:FAN | DA:2025-11-14 | 1028 Br: | 🔊 点击朗读正文 ❚❚ | Share:

High contrast label: The transparent shell is printed with black technical parameter labels (such as voltage, current, wire specifications), which are clear and easy to read, making it convenient for installation personnel to quickly confirm whether the product is suitable for the current scene and avoid model misuse.

Shell protection performance: The shell is made of high-strength engineering plastic, which has a certain degree of dust and light collision resistance, and is suitable for indoor and outdoor general electrical environments (non waterproof design, not suitable for humid or underwater scenes).

image.png

Product model and specification parameters

1. Product model and core configuration

Model, number of wire cores, shell color, lever color, core configuration features

221-412 2-core transparent orange dual wire channel, compatible with 2-channel wire splicing

221-413 3-core transparent orange three wire channel, compatible with 3-channel wire splicing

221-415 5-core transparent orange five wire channel, compatible with 5-wire splicing

Packaging form: All are individually packaged and supplied in bulk according to standard specifications (the standard packaging specification is 100 pieces/box, subject to the supplier's configuration).

2. Key technical parameters (based on international standards)

Technical indicators UL standard (North American market) ENEC standard (European and global markets) Remarks

Rated voltage 600V 450V, suitable for different regional power grid voltage standards

The maximum rated current of 20A 32A is determined based on the wire diameter and heat dissipation conditions

Maximum operating temperature 105 ° C T-Mark 85 ° C, suitable for high temperature environments (such as inside equipment)

Solid wire adaptation range AWG 24-AWG 12 0.2mm ² -4mm ² wire diameter correspondence: AWG24 ≈ 0.2mm ², AWG12 ≈ 4mm ²

Multi strand wire adaptation range AWG 24-AWG 12 0.2mm ² -4mm ² supports multi strand wires with twisted strands ≤ 36 strands

Flexible wire adaptation range AWG 24-AWG 12 0.14mm ² -4mm ² Suitable for fine twisted flexible wires (such as motor leads)

Contact resistance ≤ 5m Ω (initial value) ≤ 5m Ω (initial value) ensures low loss conductivity and reduces heat generation

Insulation resistance ≥ 100M Ω (500V DC) ≥ 100M Ω (500V DC) to ensure insulation performance and avoid leakage risk

3. Physical and mechanical properties

Shell material: transparent polycarbonate (PC), with high strength, impact resistance, and high temperature resistance characteristics;

Leverage material: Orange engineering plastic, with good mechanical strength and fatigue resistance (can be opened and closed repeatedly ≥ 100 times);

Conductive component material: high conductivity brass, surface treated with tin plating to enhance conductivity and oxidation resistance;

External dimensions (taking the 2-core model as an example): length x width x height ≈ 22mm x 12mm x 8mm (specific subject to the actual product);

Installation method: There is no fixed installation requirement, it can be freely placed in the junction box or fixed to the wiring harness with zip ties.


Product core advantages and competitive differences (compared to the 222 series)

Compare the core upgrade points of WAGO 221 series and WAGO 222 series (previous generation products) in terms of dimensions

The product has a small volume (reduced by 40% compared to the previous generation), which greatly improves space utilization and is suitable for narrow scenarios

Low operating force (lever operation is more effortless) reduces the manual intensity of batch installation to a moderate extent

The shell design is fully transparent, supporting visual inspection of semi transparent/opaque installation to enhance safety and facilitate quality control

The test slot is designed with dual front and rear test slots, with no directional restrictions and a single test slot. There are installation direction requirements to improve debugging convenience

Grip design with concave side grip area, no dedicated grip design, improved operational stability, and anti glove slippage


Installation and usage precautions

1. Installation steps

Wire processing: According to the connector identification requirements, strip the insulation layer of the wire (recommended stripping length 8-10mm, matching the length of the internal wiring terminal of the connector);

Leverage opening: Pull up the orange lever of the connector to 90 °, and the internal clamping mechanism will open, entering the wire insertion state;

Wire insertion: Fully insert the processed wire into the corresponding wiring hole of the connector, ensuring that the metal core of the wire is completely in contact with the internal conductive components and there is no insulation layer extending into the wiring hole;

Clamping and fixing: Press the lever down to the closed state, and hearing a "click" sound indicates that the clamping is in place and the wire is reliably fixed;

Visual inspection: Confirm through the transparent shell that the wire insertion depth and stripping length are compliant, and there is no exposed core wire or insulation layer clamping situation;

  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board